• 제목/요약/키워드: resistance measurement

검색결과 1,556건 처리시간 0.031초

총톤수 100톤급 활주형선의 활주 전 저항성능 개선에 관한 실험적 연구 (An Experimental Study on the Improvement of Resistance Performance at Pre-planing Condition for G/T 100 ton Class Planing Hull Form)

  • 이귀주;좌순원
    • 수산해양기술연구
    • /
    • 제40권1호
    • /
    • pp.17-22
    • /
    • 2004
  • This study was carried out at the CWC of Chosun university for the purpose of resistance performance improvement of planing hull, and the results of the tests were confirmed cooperatively with WJFEL. G/T 100 ton class planing hull form was selected, and the improvement of hull form including appendages were performed by using some model test techniques. The model test scope comprises resistance relative tests including wave profile observation, trim and sinkage measurement and flow visualization tests at full load and trial conditions for one bare hull and for two appended hulls. The final wedge and spray strip combined with improved hull form showed about 1.0 knot speed improvement at both of full and trial conditions, and outstanding improvement for fore wave phenomena.

Damage detection of composite materials via IR thermography and electrical resistance measurement: A review

  • Park, Kundo;Lee, Junhyeong;Ryu, Seunghwa
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.563-583
    • /
    • 2021
  • Composite materials, composed of multiple constituent materials with dissimilar properties, are actively adopted in a wide range of industrial sectors due to their remarkable strength-to-weight and stiffness-to-weight ratio. Nevertheless, the failure mechanism of composite materials is highly complicated due to their sophisticated microstructure, making it much harder to predict their residual material lives in real life applications. A promising solution for this safety issue is structural damage detection. In the present paper, damage detection of composite material via electrical resistance-based technique and infrared thermography is reviewed. The operating principles of the two damage detection methodologies are introduced, and some research advances of each techniques are covered. The advancement of IR thermography-based non-destructive technique (NDT) including optical thermography, laser thermography and eddy current thermography will be reported, as well as the electrical impedance tomography (EIT) which is a technology increasingly drawing attentions in the field of electrical resistance-based damage detection. A brief comparison of the two methodologies based on each of their strengths and limitations is carried out, and a recent research update regarding the coupling of the two techniques for improved damage detection in composite materials will be discussed.

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

LB막이 누적된 QCM의 저항 및 주파수 특성해석 (Resistance and Frequency Properties Analysis of QCM Coated with LB Films)

  • 강현욱;진철남;김정명;권명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.465-467
    • /
    • 1997
  • The oscillating properties of quartz Crystal Microbalance(QCM) were analyzed by electrical measurement. We tried to analyze the properties of quartz crystal coated with Langmuir-Bladgett(LB) films using the frequency and resistance at resonance in the electrical equivalent circuit. The resonant frequency was decreased linearly as to layers of LB films, however, there are some gap between theoretical values, Sauerbrey's equation and experimental values. The resistance was increase nonlinearly as to layers.

  • PDF

형성층 전기저항을 이용한 조경용 수목 활력도 분석 (Assessment of Landscape Tree Vigor Using Cambial Electrical Resistance)

  • 황동규;김동엽
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.302-306
    • /
    • 2016
  • 수목의 활력도는 다양한 방법으로 측정한다. 수목의 형성층 전기저항은 전기생리학적 진단 방법을 이용하여 수목의 활력도를 간접적으로 나타낸다. 본 연구는 Shigometer를 이용하여 몇 가지 수목의 활력도를 측정하고 수종 간 차이를 비교하고자 하였다. 그리고 개엽 시기, 방위, 수피 온도 등 전기저항 값에 영향을 주는 요인들을 파악하고자 하였다. 측정용 탐침의 길이를 일정하게 유지하여 측정오차를 최소화하였다. 대상 수종은 성균관대학교 자연과학캠퍼스에 있는 30-40년생 느티나무, 은행나무, 메타세쿼이아, 잣나무 및 튜울립나무로 하였고 각 종당 3개체를 선정하였다. 측정 시기는 2011년 3월부터 5월까지, 지면으로부터 60 cm와 흉고높이인 1.2 m에서 동서남북 4개 방위 별로 전기저항 값을 측정하였다. 수목 부근의 토양환경과 식물의 스트레스 반응을 함께 측정하였다. 측정 결과를 바탕으로 전기저항과 영향 요인과의 상관관계를 살펴보았다. 개엽 시기 이전인 3월 중순까지는 대체적으로 전기저항 값이 높았으나 4월부터 점차 낮아지기 시작하여 5월 11일에는 가장 낮은 값을 보였다. 전기저항 값의 시기별 변화는 토양수분, 토양전도도, 토양온도, 수목의 스트레스 반응과 비슷한 경향을 보였다. 잣나무의 경우 겨울에도 잎이 떨어지지 않아 측정 기간 동안 전기저항 값의 변화는 크기 않았다. 느티나무, 은행나무 및 메타세쿼이아는 남쪽 방향의 수피 온도가 다른 방위에 비하여 높았으며 전기저항 값은 가장 낮았다. Shigometer는 수목의 활력도를 현장에서 간단하게 측정함으로써 수목 관리에 유용하게 이용할 수 있을 것으로 생각된다.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Advanced Metallic Coating for the Improvement of Corrosion and Erosion Resistance of Iron Base Materials Used in Buildings and Special Works

  • Jayaraj, J.;Seok, H.K.;Byun, K.H.;Fleury, E.;Hong, K.T.
    • Corrosion Science and Technology
    • /
    • 제4권2호
    • /
    • pp.64-68
    • /
    • 2005
  • Various metallic materials are coated on Fe base materials via thermal spraying or welding process to improve both corrosion resistance as well as erosion resistance of the Fe base materials used in buildings and special works. The mechanical properties and corrosion resistance of the coat are estimated by means of hardness measurement and anodic polarization test. In additions, the effect of alloying elements and microstructure of the coatings on the mechanical and chemical properties of the coat is investigated using X- ray diffraction, Optical microscope, Transmission electron microscopy and Auger analysis. The coating deposited by tungsten inert gas (TIG) welding exhibit a good combination of hardness and corrosion properties.

트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구 (Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제12권4호
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

식료품 제조업 전기설비의 설치환경에 따른 절연저항 변화 분석 (Analysis of Insulation Resistance Change according to the Installation Environment of Food Manufacturing Electrical Equipment)

  • 정연수;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2023
  • In this study, S food manufacturing business located in Chungbuk was selected as the subject, and the transition in insulation resistance in major electrical equipment used in this food manufacturing business was analyzed for 4 years (2018-2021). It was confirmed that the insulation resistance decreased over time for all 18 electrical facilities. Insulation resistance changed due to environmental influences such as load characteristics and ambient temperature. Particularly in the case of the food manufacturing industry, it was confirmed that the decrease started after 2 years, although it varied depending on equipment and environmental influences. Furthermore, it was confirmed that management through predicting the management cycle of electrical equipment is possible by deriving a regression equation through regression analysis of insulation resistance measurement values.