• Title/Summary/Keyword: resistance management

Search Result 994, Processing Time 0.026 seconds

Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet (전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석)

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.

A study on towing power of trawlers and a proper scale of trawl gears (트롤선 유효마력과 어구의 적정 규모에 대한 연구)

  • LEE, Chun-Woo;CHOI, Kyu-Suk;JANG, Yong-Suk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Trawl fishing is a fishing method in which a large, motorized trawler tows a bag-shaped net to catch fish living at the bottom or middle layers. For a trawl gear, it is of utmost importance to select the gear size and towing speed suitable for the effective horsepower (EHP) of the trawler in the design stage. In general, the power required to move an object is proportional to the product of the object speed and resistance; therefore, there are various choices for the gear resistance and towing speed given the effective horsepower of the trawler. However, there have been few studies on the gear design of an appropriate scale for the towing speed given the effective horsepower of the trawler. In this study, the resistance and shape of three types of midwater trawl gears were analyzed using SimuTrawl, a computer simulation tool. In addition, the relationship between the propulsion force and speed of the ship was clarified when the size and effective horsepower of the trawler were determined. Finally, we suggested the relationship between the towing speed and the resistance of the gear when the trawler towed the net was investigated, and a specific method of selecting the gear size according to the towing speed.

ANOVA for Water Repellent Finish data (발수가공 데이터의 분산분석)

  • Yun, Jung-Beom
    • Journal of Korean Society for Quality Management
    • /
    • v.16 no.1
    • /
    • pp.43-48
    • /
    • 1988
  • Most of silicone used for water repellent finish is MHP (methyl hydrodiene polysiloxane), which is formed by hydrolysis and condensation polymerization of MHD (methyl hydrodiene dichlorosilane: Me H Si $Cl_2$). The cross-linking theory explains the water repellent mechanism of MHP. The silicone finish on fiber could improve in handle, softness, abrasion resistance, soil repellency, tear strength and crease resistance, as well as water repellency. According to using method silicone-water repellent finishing agents, could be devided into air dry type and curing type. MHP is the typical curing type of water repellent finishing agent, and this type requires the curing temperature above $150^{\circ}C$ at least. High curing temperature is the very drawback of this curing type. For this reason, there has been global interest in the lowering of its temperature. The objective of this study is to investigate merits of alkali treatment for silicone finishing by ANOVA and LSD (least significant difference).

  • PDF

Property Evaluation of Breathable Blend Fabric of MPCE Copolymer and Wet Coagulated Polyurethane (MPCE copolymer와 습식 폴리우레탄의 블렌드에 의한 투습방수 나일론 직물의 제반 물성변화에 관한 연구)

  • Yi, Jong-Woo;Chae, Ei-Jung;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.26 no.4
    • /
    • pp.322-330
    • /
    • 2014
  • The phospholipid-based MPCE(2-Methacryloxyethyl Phosphoryl Chlorine) copolymer was mixed with wet polyurethane for coating of nylon fabrics. The substitution rate of water in coagulation bath with DMF was changed under control of the size of formed hydrophilic microporous cell enable to manufacture excellent breathable, anti-bacterial and moisture control fabrics. Biocompatible property, vapor permeability, hydrostatic pressure, moisture management and anti-bacterial property were investigated for treated nylon fabrics. In result, increased moisture transmission rates, decreased water resistance and outstanding moisture control property could be confirmed by enhanced hydrophilicity of wet-coated nylon fabric with MPCE copolymer.

Electrochemical Characteristics of Activated Carbon Electrode for Supercapacitor (Supercapacitor용 활성탄 전극의 전기 화학적 특성)

  • 김경민;이용욱;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.273-277
    • /
    • 2002
  • In the electrode fabrication of unit cell, we found that optimal the electrochemical characteristics were obtained with at 90 wt.% of activated carbon(BP-20), 5 wt.% of conducting agent(Ppy, Super P) and 5 wt.% of P(VdF-co-HFP)/PVP mixed binder. The electrochemical characteristics of unit cell with Ppy improver were as follows : 37.6 F/g of specific capacitance, 0.98 $\Omega$ of AC-ESR, 2.92 Wh/kg and 6.05 Wh/L of energy density, and 754 W/kg and 1,562 W/L of power density. It was confirmed that internal resistance were reduced due to the increase of electrical conductivity and filling density by the introduction of conductivity agent, and content of conducting agent was suitable in the range of 4~6 wt.%. According to the impedance measurement of the electrode with conductivity agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance(AC-ESR), fast charge transfer rate at interface between electrode and electrolyte, and low RC time constant.

  • PDF

Electrode of Low Impedance by Polypyrrole Addition for Supercapacitor (폴리피롤 첨가에 의한 supercapacitor용 저 임피던스 전극)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.343-350
    • /
    • 2003
  • The best Ppy weight ratio was 7 wt% and the optimal electrode composition ratio was 78 : 17 : 5 wt.% of (MSP-20 : BP-20 =1 : 1), (Super P : Ppy =10 : 7) and P(VdF-co-HFP). Implantation of Ppy as the conducting agents have led to superior electrochemical characteristics because of the low of internal resistance and faradaic capacitance. The result of unit cell with Ppy 7 wt% were as follows: 28.02 Fig of specific capacitance, 1.34 Ω of DC-ESR and 0.36 Ω of AC-ESR. Unit cell showed a good stability up to 200 charge-discharge cycles, retaining 82% of their original capacity at 200 cycles. From the analysis of impedance, the electrodes with Ppy 7 wt% showed low ESR, low charge transfer resistance and quick reaction rate. It was inferred that quick charge-discharge was possible. As compared with the specific capacitance (rectangular shape) of CV, it was also concluded that the specific capacitance originated from thecompound phenomena of the faradaic capacitance by oxidation and reduction of Ppy and the non-faradaic capacitance by adsorption-desorption of activated carbon.

  • PDF

Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board (가속수명시험을 이용한 은도통홀 인쇄회로기판의 신뢰성연구)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.2
    • /
    • pp.15-27
    • /
    • 1997
  • This paper describes a highly accelerated life test (HALT, USPCBT) method for rapid qualification testing of STH PWB(Silver Through Hole Printed Wiring Boards). This method was carried out to be an alternative to the present time-consuming standard 1344 hours life testing(THB). The accelerated life test conditions were $121^{\circ}C$/95%R.H. at 50V bias and without bias. Their results are compared with those observed in the standard 1344 hours life test at $40^{\circ}C$/95%R.H. at 50V bias and without bias. The studies were focused on the samples time-to-failure as well as the associated conduction and failure mechanisms. The abrupt drop of insulation resistance is due to the absorption of water vapour. And the continuous drop of insulation resistance is due to the Ag migration. The ratios of time-to-failure of HALT(USPCBT) to THB were 25 and 11 at 50V bias and without bias respectively.

  • PDF

The Future of Chemical Pest Control

  • Pickett, John-A.;Woodcock, Christine-M.
    • Korean journal of applied entomology
    • /
    • v.31 no.3
    • /
    • pp.304-313
    • /
    • 1992
  • The agricultural industry is beset by continuing demands to decrease the use of pest control agents which employ toxic modes of action. Although there are real problems of pesticide resistance, and sometimes overuse or redistribution in the environment, much criticism results from a lack of appreciation of how small is the risk involved. Whatever the background reasons, research and development for pesticide alternatives, particularly within Integrated Pest Management systems, is clearly of high priority. Currently available approaches, including use of natural products and molecular biology, are often regarded with naive optimism and require critical appraisal. For the future, methods of pest control based on chemicals with non-toxic modes of action (e.g. pheromones) continue to offer promise but, for widespread use, will require their integration with biological agents and development by means of plant molecular biology.

  • PDF

Predictors and management of intravenous immunoglobulin-resistant Kawasaki disease

  • Song, Min Seob
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.4
    • /
    • pp.119-123
    • /
    • 2019
  • Kawasaki disease (KD) is a systemic vasculitis that mainly affects younger children. Intravenous immunoglobulin (IVIG) resistant cases are at increasing risk for coronary artery complications. The strategy on prediction of potential nonresponders and treatment of IVIG-resistant patients is now controversial. In this review the definition and predictors of IVIG-resistant KD and current evidence to guide management are discussed.

Effects of Soil Environments by Location on the Cambium Electric Resistance of Pinus thunbergii in Urban Park and Open Space (도시공원녹지의 입지별 토양특성이 곰솔의 형성층 전기저항에 미치는 영향)

  • Park, Seung-Burm;Nam, Jung-Chil;Kim, Seok-Kyu
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.6
    • /
    • pp.13-22
    • /
    • 2006
  • The purpose of this study is to propose rational methods in order to maintain vegetation condition and soil environment based on the analysis of tree growth in relation to the soil environment, which is one of the most significant environmental factors on vegetation condition in urban parks and open spaces. The result of the study can be described as below;The soil on every study site had strong acidity. In particular, study sites around industrial district and central business district showed extreme soil acidity. Therefore, soil management system is needed in urban parks and green spaces around those areas. Among Cambium Electric Resistance classified by locations of urban parks and open spaces, one in the costal area was the lowest. The Cambium Electric Resistance in the industrial area was the highest. Therefore, soil condition and locational environment in the industrial area are highly related to the Cambium Electric Resistance. Among the factors, which affect Cambium Electric Resistance in different locations, inorganic content was found to be the main factor in all of the study sites. Inorganic content was an important factor to the Cambium Electric Resistance in study sites located in industrial and central business districts. In the study sites located in costal area, Soil acidity was found to be other important factors that affect Cambium Electric Resistance. To improve the soil acidity, soil buffering ability should be improved from activating microorganisms in the soil by using lime and organic material, Since it takes a long time to make a change in the soil structure, well planed maintenance system is required by mid-term or long-term plans.