• Title/Summary/Keyword: resistance changes

Search Result 1,846, Processing Time 0.029 seconds

Evaluation of Thermal Durability of Thermal Barrier Coating and Change in Mechanical Behavior

  • Lee, Dong Heon;Kang, Nam Kyu;Lee, Kee Sung;Moon, Heung Soo;Kim, Hyung Tae;Kim, Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.4
    • /
    • pp.314-322
    • /
    • 2017
  • This study investigates changes in the mechanical behavior, such as changes in indentation load-displacement curve, wear resistance and contact fatigue resistance of thermal barrier coatings (TBCs) by thermal cycling test and thermal shock test. Relatively dense and porous TBCs on nickel-based bondcoat/superalloy are prepared; the highest temperature applied during thermal durability test is $1350^{\circ}C$. The results indicate that the porous TBCs have relatively longer lifetime during thermal cycling and thermal shock tests, while denser TBCs have relatively higher wear and contact fatigue resistance. The mechanical behavior is influenced by sintering of the TBCs by exposure to high temperature during tests.

Identification of Electrical Resistance of Fresh State Concrete for Nondestructive Setting Process Monitoring

  • Shin, Sung Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.6
    • /
    • pp.414-420
    • /
    • 2015
  • Concrete undergoes significant phase changes from liquid to solid states as hydration progresses. These phase changes are known as the setting process. A liquid state concrete is electrically conductive because of the presence of water and ions. However, since the conductive elements in the liquid state of concrete are consumed to produce non-conductive hydration products, the electrical conductivity of hydrating concrete decreases during the setting process. Therefore, the electrical properties of hydrating concrete can be used to monitor the setting process of concrete. In this study, a parameter identification method to estimate electrical parameters such as ohmic resistance of concrete is proposed. The effectiveness of the proposed method for monitoring the setting process of concrete is experimentally validated.

Reappearance of the Electrical Poor Contact in Connectors by Fretting Wear (프렛팅 마모에 의한 커넥터 단자의 접촉불량 재현)

  • Kim, Seong-Woo;Jung, Won-Wook;Wei, Shin-Hwan;Kim, Hyung-Min;Park, Sung-Bae;Lee, Dong-Hun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1361-1366
    • /
    • 2008
  • Failure mechanism of the poor contact is analyzed on the basis of used connectors and this poor contact of connectors is reappeared by the new forced fretting wear method. As the result of failure analysis and reappearance, fretting wear and corrosion of the contact interface causes the contact resistance degradation and the poor contact of connectors. The amount of degradation depends on the fretting stroke. Changes in contact resistance of static contacts are likely to be small and gradual, while motions of contact interface may result in larger and discontinuous changes in resistance and voltage. This voltage drop by fretting motions is large enough to cause the distortion of sensor signal and mis-working of electric components.

  • PDF

Cooperative Interaction between Acid and Copper Resistance in Escherichia coli

  • Kim, Yeeun;Lee, Seohyeon;Park, Kyungah;Yoon, Hyunjin
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.5
    • /
    • pp.602-611
    • /
    • 2022
  • The persistence of pathogenic Escherichia coli under acidic conditions poses a serious risk to food safety, especially in acidic foods such as kimchi. To identify the bacterial factors required for acid resistance, transcriptomic analysis was conducted on an acid-resistant enterotoxigenic E. coli strain and the genes with significant changes in their expression under acidic pH were selected as putative resistance factors against acid stress. These genes included those associated with a glutamate-dependent acid resistance (GDAR) system and copper resistance. E. coli strains lacking GadA, GadB, or YbaST, the components of the GDAR system, exhibited significantly attenuated growth and survival under acidic stress conditions. Accordantly, the inhibition of the GDAR system by 3-mercaptopropionic acid and aminooxyacetic acid abolished bacterial adaptation and survival under acidic conditions, indicating the indispensable role of a GDAR system in acid resistance. Intriguingly, the lack of cueR encoding a transcriptional regulator for copper resistance genes markedly impaired bacterial resistance to acid stress as well as copper. Conversely, the absence of YbaST severely compromised bacterial resistance against copper, suggesting an interplay between acid and copper resistance. These results suggest that a GDAR system can be a promising target for developing control measures to prevent E. coli resistance to acid and copper treatments.

Proteomics in Insecticide Toxicology

  • Park, Byeoung-Soo;Lee, Sung-Eun
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.1
    • /
    • pp.11-18
    • /
    • 2007
  • Mechanisms of insecticide resistance found in insects may include three general categories. Modified behavioral mechanisms can let the insects avoid the exposure to toxic compounds. The second category is physiological mechanisms such as altered penetration, rapid excretion, lower rate transportation, or increased storage of insecticides by insects. The third category relies on biochemical mechanisms including the insensitivity of target sites to insecticides and enhanced detoxification rate by several detoxifying mechanisms. Insecticides metabolism usually results in the formation of more water-soluble and therefore more readily eliminated, and generally less toxic products to the host insects rather than the parent compounds. The representative detoxifying enzymes are general esterases and monooxygenases that catalyze the toxic compounds to be more water-soluble forms and then secondary metabolism is followed by conjugation reactions including those catalyzed by glutathione S-transferases (GSTs). However, a change in the resistant species is not easily determined and the levels of mRNAs do not necessarily predict the levels of the corresponding proteins in a cell. As genomics understands the expression of most of the genes in an organism after being stressed by toxic compounds, proteomics can determine the global protein changes in a cell. In this present review, it is suggested that the environmental proteomic application may be a good approach to understand the biochemical mechanisms of insecticide resistance in insects and to predict metabolomic changes leading to physiological changes of the resistant species.

Non-destructive Detection of Creep Damage Based on Electric Resistance Technique (전기저항법에 의한 크리프 손상의 비파괴적 검출)

  • Lee, H.M.;Yoon, K.B.;Nahm, S.H.;Soh, C.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.7 no.3
    • /
    • pp.155-159
    • /
    • 1994
  • As Cr-Mo-V steels have excellent mechanical and creep properties at elevated temperatures, they are extensively used in power plants. However, the steam turbine components are supposed to have suffered material degradation during long-term service at elevated tenperatures. Many efforts have been made to assess the safety and residual life of these components by means of non-destructive methods such as plastic replication, hardness and electric resistance techniques. Recently, a parameter correlating hardness changes during long-term heating to those during creep was introduced and it was named 'G parameter'. The electric resistivity as well as hardness are affected by damage accumulation, but there have been no efforts to correlate G parameter to resistivity changes. In this study, relationship between G parameter and changes in electric resistivity was investigated using artificially aged Cr-Mo-V steel. It is well understood that G parameter can be applied to electric: resistance techmique.

  • PDF

A STUDY ON THE STAIN RESISTANCE OF DENIAL CERAMICS FOR ALL CERAMIC CROWN (전부도재관용 도재의 염색 저항성에 관한 연구)

  • Son, Oe-Soo;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.416-424
    • /
    • 1999
  • Simulation of naturally appearing enamel in fixed prosthodontics could be achieved with all ceramics. The purpose of this study was to investigate the stain resistance of 4 different all ceramics materials (In-ceram, IPS Empress, Celay, Vintage). Forty specimens were prepared using manifacture's instruction and the samples were divided into two groups. The specimens for one group were glazing and those for other group were ground to remove the glazing layer. All specimens were immersed in methylene-blue for 24hours. The color values for each specimen was measured with colorimeter (Mode Tc-6Fx, Tokyo Denshoku Co.) prior to and after immersion in methylene-blue. The following conclusions were drawn from this study. 1 The stain resistance of glazing ceramics was higher than that of unglazing ceramics. 2. The changes of ${\Delta}E^*$\;and\;L^*$ values were revealed in Vintage and unglazing Celay. 3. The changes of $a^*$ values were revealed in unglazing vintage, Celay, In-ceram. 4. The changes of $b^*$ value were revealed in Vintage, IPS Empress and unglazing Celay.

  • PDF

Evaluation of DC Resistive Humidity Sensors Based on Conductive Carbon Ink (전도성 카본 잉크를 이용한 직류 저항형 습도센서 제작 및 평가)

  • An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.397-401
    • /
    • 2017
  • A DC resistance type humidity sensor using conductive carbon ink was fabricated and its performance was evaluated. The humidity sensor was fabricated using a screen printing technique and have a structure that does not require additional metal electrodes to measure resistance change. To evaluate the performance of the humidity sensor, we measured the DC resistance change under various relative humidity levels. The fabricated humidity sensor showed a resistance change of about $2.5{\sim}50k{\Omega}$ in 11 ~ 95% RH environment. It also shows a linear relationship in the relative humidity versus log DC resistance graph. In comparison with commercial humidity sensor under real environment, it can be confirmed that the resistance of the humidity sensor changes to almost the same level as the measured humidity. These results show that the resistance type humidity sensor can be operated stably in actual environment.

An Experimental Study on the Fire Resistance Performance of Intumescent Coating System with Time Elapse (경년변화에 따른 내화도료의 내화성능에 관한 실험적 연구)

  • Kim, Dae-Hoi;Sung, Si-Chang;Choi, Dong-Ho;Park, Soo-Young;Lee, Sea-Hyun;Lee, Jong-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.61-64
    • /
    • 2008
  • Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system.

  • PDF

STAINING RESISTANCE OF THE SOFT DENTURE LINERS (연성 의치상 이장재의 염색 저항성에 관한 연구)

  • Kim, Kwang-Jun;Cho, Hye-Won;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.492-499
    • /
    • 2000
  • This study was investigated to compare the staining resistance of soft denture liners. Specimens were made of Coe-soft, Coe-comfort, Soft-liner, Visco-gel, and were stored in 1% methyleneblue solution for 24 hours. The amounts of color change before and after treatment with mono-poly and thermocycling were measured by colorimeter(TC-6FX, Tokyo Denshoku Co. Ltd, Japan) for evaluation of staining resistance. The following conclusions were drawn from this study. 1. The staining resistance of Visco-gel was increased, but there was no changes of staining resistance in Coe-soft, Coe-comfort, and Soft-liner after treatment with monopoly. 2. The staining resistance of the Coe-comfort was the least in all soft denture liners. 3. The staining resistance of Visco-gel and Soft-liner were decreased after thermocycling.

  • PDF