An Experimental Study on the Fire Resistance Performance of Intumescent Coating System with Time Elapse

경년변화에 따른 내화도료의 내화성능에 관한 실험적 연구

  • Published : 2008.04.24

Abstract

Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system.

Keywords