• Title/Summary/Keyword: resin acid

Search Result 777, Processing Time 0.024 seconds

Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material

  • Erdemir, Ugur;Sancakli, Hande Sar;Sancakli, Erkan;Eren, Meltem Mert;Ozel, Sevda;Yucel, Taner;Yildiz, Esra
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.434-443
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. MATERIALS AND METHODS. A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of $6mm{\times}4mm$ and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with $30{\mu}m$ silica oxide particles ($Cojet^{TM}$ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at ${\alpha}=.05$. RESULTS. Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (P<.05). Hydrofluoric acid etching and silica coating yielded the highest shear bond strength values (P<.001). CONCLUSION. Self-adhering flowable composite resin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used.

Synthesis of $\textrm{N}_{G}$-Mon $o^{14}\textrm{C}$-methyl]-L-arginine ($\textrm{N}_{G}$-Mon $o^{14}\textrm{C}$-methyl]-L-arginine의 합성)

  • 조영봉
    • Environmental Analysis Health and Toxicology
    • /
    • v.1 no.1
    • /
    • pp.77-80
    • /
    • 1986
  • Radiochemical synthesis of $N^{G}$-mono[$^{14}$ C-methyl]-L-arginine is described. The compound was synthesized from radio-active mono[$^{14}$ C]-methylamine as easily and purified by strong cation-exchange resin (NH form) liquid chromatography using a gradient of ammonium hydroxide, and crystallized as flavianate. The free amino acid was successfully prepared by strirring its flavianate and strong anion-exchange resin (OH- form), which could remove the flavianic acid from its salt in water below room temperature. Purity of the compound was tested by thin-layer chromatography, thin-layer electro-phoresis, and scintillation spectrometry.y.

  • PDF

Technology Trends for Photoresist and Research on Photo Acid Generator for Chemical Amplified Photoresist (포토 레지스트의 기술 동향과 화학 증폭형 포토레지스트에서의 광산 발생제의 연구)

  • Kim, Sung-Hoon;Kim, Sang-Tae
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.252-264
    • /
    • 2009
  • Lithographic data obtained from PHS(polyhydroxy styrene) having various functionalities were investigated by using a photoacid generator based on diazo and onium type. Chemically amplified photoresist based on the KrF type photoresist was developed by using a photoacid generator and multi-functional resin. Thermal stability for the photoacid generator showed that the increase of loading amount of photoacid generator resulted in the decrease of glass transintion temperature (Tg). The photoacid generators having methyl, ethyl, or propyl group in their cationic structure produced T-top structure in pattern profile due to the effect of acid diffusion during the generation of acid in the resist. The increase of carbon chain length in the anionic structure of photoacid generators resulted in lower pattern resolution due to the interruption of acid diffusion.

  • PDF

The Methanogenic Toxicity of Wood Resin Constituents (메탄생성균에 대한 Wood resin 구성성분의 독성에 관한 연구)

  • 장봉기;허준무;손부순;박종안
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.139-147
    • /
    • 1997
  • 펄프폐수 내에 존재하는 대표적인 수지 구성성분의 일종인 wood resin 화합물이 메탄생성균에 미치는 독성을 평가하기 위한 회분식 독성실험을 수행하였다. 수지는 극성용매로 추출가능한 몇몇 wood 구성성분의 혼합물로서 수지의 주요 구성성분은 긴 사슬 휘발성유기산, terpenes, resin acids, 리그난과 극성 페놀류들이다. 메탄생성균의 독성실험은 $30^{\circ}C$에서 표준회분식 실험방법을 채택하였고 식종물질로서는 입상슬러지를 사용하였다. 극성페놀의 한 종류인 4-hydroxystilbene가 가장 높은 독성을 나타내었으며, 50% 저해를 일으키는 농도는 $20mg/\ell$이었다. Resin acid와 휘발성 terpene 역시 메탄생성균에 독성을 나타내었으며, 50% 독성을 일으키는 농도는 $43{\;}~{\;}330mg/\ell$이었다. 반면에 triterpenes은 1,000 to $1,300{\;}mg/\ell$의 상대적으로 높은 농도에서도 메탄생성균에 독성을 일으키지 않았다. 따라서 wood resin의 구성성분이 몇몇 펄프폐수의 혐기성 처리에 있어서 독성을 일으키는 주요물질이었다.

  • PDF

Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

  • Koodaryan, Roodabeh;Hafezeqoran, Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.504-510
    • /
    • 2016
  • PURPOSE. Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. MATERIALS AND METHODS. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (${\alpha}=.05$). RESULTS. The bond strength values of A and S were significantly higher than those of N (P<.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG (P<.001). CONCLUSION. The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

The effects of different surface treatments on the shear bond strengths of two dual-cure resin cements to CAD/CAM restorative materials

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem;Basar, Ebru Kaya;Ozarslan, Mehmet Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.189-196
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS. In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 ㎛ Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen's treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strength using TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bonding performance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.

Effect of ascorbic acid, ethanol and acetone on adhesion between the treated fiber posts and composite resin cores

  • Zahra, Khamverdi;Reza, Talebian
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.187-191
    • /
    • 2012
  • PURPOSE. The aim of the present study was to assess the effect of ascorbic acid, ethanol and acetone on microtensile bond strength between fiber posts pre-treated with hydrogen peroxide and composite resin cores. MATERIALS AND METHODS. Twenty four fiber posts were pre-treated with 24% hydrogen peroxide and divided into 4 groups as follows: G1: no treatment, as control group; G2: treatment with10% ascorbic acid solution for 5 minutes; G3: treatment with 70% ethanol solution for 5 minutes; and G4: treatment with 70% acetone solution for 5 minutes. Each fiber post was surrounded by a cylinder-shaped polyglass matrix which was subsequently filled with composite resin. Two sections from each sample were selected for microtensile test at a crosshead with speed of 0.5 mm/min. Statistical analyses were performed using one-way ANOVA and a post hoc Tukey HSD test. Fractured surfaces were observed under a stereomicroscope at ${\times}20$ magnification. The fractured surfaces of the specimens were observed and evaluated under a SEM. RESULTS. Means of microtensile bond strength values (MPa) and standard deviations in the groups were as follows: G1: $9.70{\pm}0.81$; G2: $12.62{\pm}1.80$; G3: $16.60{\pm}1.93$; and G4: $21.24{\pm}1.95$. G4 and G1 had the highest and the lowest bond strength values, respectively. A greater bond strength value was seen in G3 compared to G2. There were significant differences between all the groups (P<.001). All the failures were of the adhesive mode. CONCLUSION. Application of antioxidant agents may increase microtensile bond strength between fiber posts treated with hydrogen peroxide and composite cores. Acetone increased bond strength more than ascorbic acid and ethanol.

Purification of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) Esters from Squid Oil by Silver Ion Chromatography (은 이온 크로마토그래피에 의한 오징어유로부터 eicosapentaenoic acid(EPA) 및 docosahexaenoic acid(DHA)의 분리농축)

  • Gyoung, Young-Soo;Yu, Ying-Lian;Yoon, Jung-Ro
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.361-364
    • /
    • 2004
  • EPA and DHA extracted from methyl esterified squid oil were purified by silver exchanged resin, silver nitrate-impregnated silica gel, silver exchanged zeolite, and silica gel column chromatography, among which column chromatography using mixture of silver exchanged resin and silica gel (10% by weight) showed the best result. By this simple purification method, EPA and DHA were concentrated from 12.5 to 27.9% (yield, 86,0%) and from 21.7 to 49.5% (yield, 87.3%), respectively. Silver exchanged resin had additional advantages of outstanding reusability and simple recovery of silver.

Study on chemical properties of Pinus koraiensis Sieb. et Zucc. resin (잣나무 송지(松脂)의 화학적(化學的) 성상(性狀)에 관(關)한 연구(硏究))

  • Kang, Ha-Young;Hwang, Byung-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.3-7
    • /
    • 1976
  • This is to reveal the chemical properties of resin of Pinus koraiensis Sieb. et Zvcc, and to give the basic data to resin chemistry and resin processing field. Its results are given; 1) Acid value was shown as 134.12 2) Saponification value was shown as 172.72 3) Iodine value was shown as 109.93 and therefore, it is considered as semi-boiled oil. 4) Ester value was shown as 41.60 5) Moisture content was shown as 11.28% 6) The impurities of resin was shown as 0.09% 7) The amount of turpentine oil was shown as 23.29% 8) Rosin content was shown as 76.74% 9) The amount of resin acid was shown as 72.33% 10) Unsaponification matter was shown as 4.41% 11) The refractive index of resin was shown as 1.5045 at $N^{20}_D$.

  • PDF

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

  • Kim, Su-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 2009
  • STATEMENT OF PROBLEM. The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE. This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND MATHODS. Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS. The primers significantly(P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy $primer^{(R)}$(MDP monomer) showed higher bond strength than those primed with the MR $bond^{(R)}$(MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS. The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy $primer^{(R)}$, which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR $bond^{(R)}$, which contains the carboxylic acid monomer, MAC-10.