• Title/Summary/Keyword: residual concentration

Search Result 1,001, Processing Time 0.025 seconds

The Effect of Turbidity and Alkalinity on the Regidual Aluminum Concentration (탁도(濁度) 및 알카리도(度)가 잔류(殘留)알루미늄 농도(濃度)에 미치는 영향(影響))

  • Choi, Suingil;Lee, Changsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.88-98
    • /
    • 1995
  • Several kinds of coagulants such as aluminum sulfate, PAC, PASS are being used to treat drinking water resulting in residual aluminum ions in the water. Recently, it has been reported that high intake of aluminum ion may cause neurological dieseases such as Alzheimer's diesease and presenile dementia. Because of the possible adverse effect, WHO and EEC recommand to regulate residual aluminum. The autorities in Korea also has plan of regulating residual alunimum from 1995. But there is not enough information about the range of residual aluminum ion concentration when the aluminum sulfate, PAC or PASS has been used as a coagulant. Therefore the study has been conducted to find out the range of residual aluminum ion concentration after using aluminum sulfate, PAC, and PASS. Furthermore the effect of turbidity and alkalinity have been investigated. The experimental results are summarized as; 1. Most of the residual aluminum ion concentrations were within $10^{-6}$ and $10^{-5}mole/l$. Three coagulants have not showed any considerable difference in the residual aluminum concentration up to 50 NTU. However PAC has showed the least residual aluminum in high turbidity water over 100 NTU. 2. The low alkalinity water having 25mg/l as $CaCO_3$ has showed less residual aluminum than the water having 50mg/l alkalinity. However, the difference was not significcant. 3. Even the lowest residual aluminum concentration was over 0.05mg/l. Therefore the process to reduce residual aluminum would be necessary in water treatment plants.

  • PDF

A Study on the Factors to Minimize the Residual Aluminum in Filtered Water (정수처리시 잔류알루미늄 농도를 최소화하기 위한 영향인자 고찰)

  • 고영송;우달식;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.2
    • /
    • pp.1-9
    • /
    • 1993
  • In public water supply systems, Alum and/or PAC being used as a coagulant. It is well known that their use increased frequently the concentration of residual aluminum in filtered water upon operating conditions. This study was conducted to find the optimum conditions that both the concentration of residual aluminum and turbidity are minimized by changing such factors as pH, temperature, alum dosage, mixing rate, alkalinity and hardness. The results can be summarized as follows: The pH values for the minimum concentration of residual aluminum and turbidity as a given experimental condition were found at pH 6 and pH 7 respectively, the apparent clarity was best at pH 8. The floc settling rate was the greatest at pH 6.5, but the turbidity was high at the same condition. The more alum dosage, the higher the concentration of residual aluminum. However the alum dosage less than 15 mg/l tend to decrease in turbidity. Restabilization and enmeshment occurred near 15 mg/l and 20 mg/l of alum dose respectively. With the increase of mixing rate (rapid and slow), the concentration of residual aluminum and turbidity are increased and the same trend was found in increment of mixing time. At low water temperature, the concentration of residual aluminum was decreased, but turbidity was increased. It was confirmed that alkalinity had an effect on the coagulation efficiency, but hardness did not.

  • PDF

Effects of Ni Concentration on Residual Stress in Electrodeposited Ni Thin Film for 63Ni Sealed Source (63Ni 밀봉선원용 Ni 전기도금 박막에서 Ni 농도가 잔류응력에 미치는 영향)

  • Yoon, Pilgeun;Park, Deok-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • Chloride plating solution was fabricated by dissolving metal Ni powders in a mixed solution with HCl and de-ionized water. Effects of $Ni^{2+}$ and saccharin concentrations in the plating baths on current efficiency, residual stress, surface morphology and microstructure of Ni films were studied. In the case of $0.2M\;Ni^{2+}$ concentration, current efficiency was decreased to about 65 % with increasing saccharin concentration, but, in the case of $0.7M\;Ni^{2+}$ concentration, it was shown more than 90 % with the increase of saccharin concentration. Residual stress of Ni thin film was appeared to be about 400 MPa up to 0.0244 M saccharin concentration at the $0.2M\;Ni^{2+}$ concentration and surface morphology with severe cracks was observed in the range of 0.0487~0.0975 M saccharin concentration. Residual stress of Ni thin films was measured to be about 750 MPa without saccharin addition and 114~148 MPa at the range of 0.0097~0.0975 M saccharin concentration for the $0.7M\;Ni^{2+}$ concentration. Relatively low residual stress values (114~148 MPa) of the Ni films at the range of 0.0097~0.0975 M saccharin concentration may be resulted from codeposition of S from saccharin. Ni films at $0.7M\;Ni^{2+}$ concentration showed smooth surface morphology and were independent of saccharin concentration. Ni films at $0.7M\;Ni^{2+}$ concentration consist of FCC(111), FCC(200), FCC(220) and FCC(311) peaks and the intensities of FCC(111) and FCC(200) peaks increased with increasing saccharin concentration. Also, the average grain size decreased with increasing saccharin concentration from about 30 nm to about 15 nm.

A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System (정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구)

  • Kim, Young Hoon;Kim, Kwan Yeop;Kim, Ji Hoon;Lee, Yong Soo;Lee, Eui Jong;Eom, Jung Yeol;Kim, Hyung Soo;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

Variations of Surface Ozone Concentration by Vertical Downward Mixing of Ozone in the Residual Layer of the Atmospheric Boundary Layer at the Busan Coastal Area (부산연안역의 대기경계층내 잔류 오존의 연직하향혼합에 의한 지표 오존농도의 변화 특성)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.417-422
    • /
    • 2001
  • The vertical structure of atmosphere was observed In investigate the variation of surface ozone concentration by vertical downward mixing of residual ozone in the atmospheric boundary layer at the Busan coastal area. Airsonde and pilot balloon measurements were made at Gamcheondong and the Kimhae airport for April 26~27, 1996. The vertical potential of potential temperature showed a residual layer between 510m and 1800m from 2100LST April 26 to 0900LST April 27. The downward mixing of ozone in the residual layer of the atmospheric boundary layer was confirmed from vertical profile of mixing ratio near 600m in the morning. The thickness of the sea breeze layer was 900m at 1500LST April 26. Thereafter, it become to be lowered with time A low level jet was measured near 900m at 0300LST on April 27 from a pibal measurement. Early morning sharp increase of surface ozone concentration at the Busan coastal area was caused by vertical downward mixing of ozone concentration rather than by photochemical reaction In the atmospheric boundary layer.

  • PDF

Effect of Cu2+ Concentration and Additives on Properties of Electrodeposited Cu Thin Films for FCCL from Sulfate Baths (황산염용액으로부터 전기도금 된 FCCL용 Cu 필름의 특성에 미치는 Cu 이온농도 및 첨가제의 영향)

  • Shin, Dong-Yul;Park, Doek-Yong;Koo, Bon-Keup
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.191-196
    • /
    • 2009
  • Nanocrystalline Cu thin films were electrodeposited from sulfate baths and investigated systematically the influences of $Cu^{2+}$ concentration and additives on current efficiency, residual stress, surface morphology, and XRD patterns of electrodeposited Cu film. Current efficiency was nearly 100% at from 0.2M to 1.0 M $Cu^{2+}$ concentration. but it was linearly increased with $Cu^{2+}$ concentration at less than 0.2M. The residual stress was observed in range of 7.9 to 18.4 MPa and tensile stress mode. Dendritic and powdered form was obtained at below 0.1 M. As increased with $Cu^{2+}$ concentration in solution, the main peak in the XRD pattern shifted (111) and (220) from (200). In the other hand, all about 100% current efficiency observed in all additive concentration systems, and residual stress observed in range of 20.4 to 26.3 MPa tensile stress. The condition 5(Ultra make-up - 10 ml/l, Ulta A - 0.5ml/l, Ultr B - 0.5 ml/l) was good surface morphology, and fcc(111) peak in XRD patterns increased with increasing additive concentration.

Some heavy metal concentration of surface sediments from the southwestern coast of Korea (서남해안 연근해저 퇴적물의 중금속 함량 및 분포)

  • 전수경;조영길
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1299-1305
    • /
    • 2002
  • Thirty sediment samples of the <63${\mu}{\textrm}{m}$ fraction collected from the southwestern coast of Korea were analysed for their heavy metal (Fe, Mn, Cr, Co, Cu, Ni, Zn and Pb) concentration. The results show that sediment texture plays a controlling role on the total metal concentrations and their spatial distribution. A single lM HCl extraction procedure was used in order to assess the environmental risk of heavy metals in bottom sediments. The non-residual fraction was the most abundant pool for Mn and Pb in most samples, which means that this metals are highly avaliable in these sediments. Cr, Ni, Fe, Co, Zn and Cu were mainly associated with the residual fraction, suggesting that their concentrations are controlled significantly by transport processes with the fine particles as carriers from diffuse pollution source. Concentration enrichment ratios(CER) were calculated from the non-residual contents and their values allowed us to classify the sediments according to their environmental risk.

A Study on Elimination of Captan Residues Sticked on Spinach (시금치에 부착시킨 Captan의 제거에 관한 연구)

  • 정인철;차경숙;임채원;김성준;문윤희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.214-218
    • /
    • 1995
  • Elimination of residual captan during the storage and cooking process was investigated. The concentration of residual captan after sticking and drying fo captan on spinach was 2.938ppm. During storage of 5, 10, 15 and 20 days at 15$^{\circ}C$, the amount of residual captan decreased to 73.18, 80.80, 89.99 and 98.40% of the initial amount, respectively. When spinach was stored at 3$^{\circ}C$, the concentration of residual captan decreased to 58.20, 61.37, 72.84 and 76.31% and the storage was carried out at -17$^{\circ}C$, residual captan amount decreased to 7.18, 22.67, 34.58 and 40.91% of the initial amout, respectively according to the storage period. In the case of the residual captan of seasoned spinach, the storage of 2, 24 and 48 hours at 15$^{\circ}C$, the amout of residual captan decreased to 0.772(39.69%), 0.661(77.50%) and 0.063ppm(97.86%) of the initial amount, respectively. When spinach was stored at 3$^{\circ}C$, the amount of residual captan decreased to 2.344 (20.22%), 1.021(65.25%) and 0.329ppm(88.80%) and the storage was carried out at -17$^{\circ}C$, residual captan amount decreased to 2.428(17.36%), 1.520(48.26%) and 0.726ppm(75.29%) of the initial amount, respectively according to the storage period. In the case of the residual captan of spinach cooked with edible oil for 2, 4 and 6 minutes and then cooking oil was discarded, each decreasing rate of the captan sticked to thespinach was 96.29, 97.86 and 99.18%, respectively. The rate of removed the captan sticked to the spinach with oil was 73.32, 86.32 and 87.13%, respectively. From these results, the storage in room temperature and the addition of seasoning to the spinach could lead to decrease in the concentration of the residual captan, furthemore the cooking could inhance decreasing of residual captan.

  • PDF

A Numerical Study of the Residual Hydrogen Concentration in the Weld Metal (용접금속 잔류수소농도의 수치해석 연구)

  • Yoo, Jinsun;Ha, Yunsok;S.R., Rajesh
    • Journal of Welding and Joining
    • /
    • v.34 no.6
    • /
    • pp.42-46
    • /
    • 2016
  • Hydrogen assisted cracking (HAC) is one of the most complicated problem in welding. Huge amount of studies have been done for decades. Based on them, various standards have been established to avoid HAC. But it is still a chronic problem in industrial field. It is well known that the main causes of the hydrogen crack are residual stress, crack susceptible micro structures and a certain critical level of hydrogen concentration. Even though the exact generating mechanism is unclear till today, it has been reported that the hydrogen level in the weld metal should be managed less than a certain amount to prevent it. Matsuda studied that the residual hydrogen level in the weld metal can be varied even if the initial hydrogen content is same. It is also insisted in this report that the residual hydrogen concentration is in stronger correlation with hydrogen crack than the initial hydrogen content. But, in practical point of view, the residual hydrogen is still hard to consider because measuring hydrogen level is time and cost consuming process. In this regard, numerical analysis is the only solution for considering the residual hydrogen content. Meanwhile, Takahashi showed the possibility of predicting the residual hydrogen by a rigorous FE analysis. But, few commercial software suitable for solving the weld metal hydrogen has been reported yet. In this study, two dimensional thermal - hydrogen coupled analysis was developed by using the commercial FE software MARC. Since the governing equation of the hydrogen diffusion is similar to the heat transfer, it is shown that the heat transfer FE analysis in association with hydrogen diffusion property can be used for hydrogen diffusion analysis. A series of simulation was performed to verify the accuracy of the model. For BOP (Bead-On-Plate) and the multi-pass butt welding simulations, remaining hydrogen contents in the weld metal is well matched with measurements which are referred from Kim and Masamitsu.

Development of optimization model for booster chlorination in water supply system using multi-objective optimization method (다목적 최적화기법을 활용한 상수도 공급계통 잔류염소농도 최적운영 모델 개발)

  • Kim, Kibum;Seo, Jeewon;Hyung, Jinseok;Kim, Taehyeon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.