수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안 (Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan)

  • 한금석;박주현;박영복;김성재;김현돈;최영준;최인철;홍성호
    • Corrosion Science and Technology
    • /
    • 제17권1호
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발 (Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network)

  • 정보배;김기범;서지원;구자용
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구 (A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks)

  • 노유래;김상효;최성욱;박준홍
    • 한국방재안전학회논문집
    • /
    • 제9권2호
    • /
    • pp.63-75
    • /
    • 2016
  • 안전한 수돗물 공급을 위해 정수처리장부터 최종 단계인 수도꼭지까지 일정 수준 이상의 잔류염소농도가 유지되어야 한다. 하지만 국내 문헌에 따르면 상수공급의 전체 과정 중에 30-60%의 잔류염소가 소실되고, 이에 대한 주요 원인으로 정수처리 과정에서 염소 사용량 감소 추세, 급수배관 내에서 염소분해 손실, 여름철의 높은 온도에 의한 잔류염소 분해 속도 증가, 급수배관의 노후화에 따른 잔류염소 손실, 저수조 내 저장 시 잔류염소 감소 발생 등이 파악되었다. 이러한 이유로 저수조를 거치는 급수 방식의 경우 최종 수도꼭지의 잔류염소 농도가 기준치보다 낮아질 개연성이 높고, 용량과 체류시간을 단순히 고려하는 기존의 저수조 설계 방식으로 인해서 수돗물 공급의 안전성에 대한 우려가 존재한다. 이의 개선 방안 도출을 위해서 본 연구에서는 저수조 내 잔류염소 감소에 관여하는 주요 기작들인 수체 내 잔류염소 분해, 벽체 표면 흡착, 그리고 증발에 의한 물질전달을 수학적으로 묘사하는 공식들과 계수 값들을 문헌을 통해서 획득하고, 일반적 저수조 조건에서 모델 시뮬레이션을 수행하였다. 그 결과 저수조에 유입되는 수돗물 내 유기물 농도, 수돗물이 저수조에 유입되는 수리학적조건(난류 정도), 그리고 저수조 벽체 표면 재질의 흡착능 등이 저수조 내 잔류염소 감소에 주요 영향 인자들임을 알 수 있었다. 본 연구에서 획득된 결과들은 잔류염소 감소를 최소화하여 안전한 수돗물 공급을 가능하게 하는 새로운 저수조 설계기법이나 기술 개발에 유용하게 활용될 것이다.

서울시 수도수 중의 위생물학적 조사연구 (A Microbiological Study on the Tap Water in Seoul)

  • 조영채
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.33-41
    • /
    • 1981
  • This study was carried out to investigate Water Temperature, Residual Chlorine, Coliform Groups, and the Standard Plate Counts of Water Supply Areas provided by 7 Water Purification Plant (W.P.P) in Seoul from September 20, 1979 through October 20, 1979. The results were summarized below: 1) The mean water temperature of the 63 Water Samples was 19.8$\circ$C, the mean pH 7.18, and the mean residual chlorine concentration 0.52 ppm by each Water Supply Areas. There is no statistically significant differences between the WPP Areas, but there is significant differences between water supply areas. 2) 30(47.6%) out of the 63 Water Samples were Standard Plate Counts free and 33 Samples (52.4%) were contaminated by Standard Plate Counts. 30 (47.6%) out of 33 samples showed the existence of Standard Plate Counts less than 15 and the other 3 samples 15-30. 3) 2 (3.2%) out of the 63 Samples had the coliform. Those 2 Samples had 2 and 6 coliform group counts per 50ml respectively both of them were 0.1ppm in residual chlorine. 4) There is correlation among Water Temperature, pH, Residual Chlorine, Standard Plate Counts, and Coliform Groups. The Coefficient of Correlation(r) between Water Temperature & Residual Chlorine was 0.147, 0.240 between Water Temperature & Standard plate Counts and 0.215 between pH & Standard Plate Counts. These correlations are statistically no significant, But the correlation of coefficient between pH & Residual Chlorine was -0.291 which is showed significant correlation at p<0.05. The coefficient of correlation between Residual Chlorine & Standard Plate Counts was -0.441 which is showed Negative Correlation Statistically Significant difference at p<0.01.

  • PDF

잔류염소 측정용 전기화학센서의 유효성 (Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement)

  • 김홍원;정남용
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

배수관망의 잔류염소 평활화를 위한 최적 재염소 처리 (Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems)

  • 윤재흥;오정우;최영송
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측 (Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City)

  • 김경록;이병희;유효식
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

관로 내 적정소독능 확보를 위한 재염소 기법의 적용 (Application of Rechlorination for Adequate Disinfection Ability in Water Distribution System)

  • 이두진;김영일;이종민;정남정;김용운
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.701-707
    • /
    • 2006
  • Disinfectant residual should be maintained to achieve biological stability during distribution of treated water. The wide distribution of retention times associated with storage and transport of water in a network and the reactivity of disinfectants make it difficult to maintain adequate residuals at critical locations. Rechlorination at some intermediate locations may reduce the total disinfectant dose while keeping residuals within specified limits throughout the water distribution system. In order to select the adequate location of rechlorination for achieving to maintain of residual chlorine throughout the distribution system, EPANET was used in this study. EPANET was well predicted chlorine transport and residual loss in the distribution system. Location of rechlorination was selected to maintain 0.4mg/L of residual chlorine throughout a water distribution system by field investigation and model simulation. The quantity of chlorine may reduced 36.7% and provided smooth residual between 0.42 and 0.60mg/L, when rechlorination would be used continuously at strategic location within the distribution system.

대구 지역의 계절 변화에 따른 급수관내 잔류염소 농도 거동 (The Seasonal Variation of Free Chlorine Residuals by Water Supply Distance in Daegu)

  • 이태관
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.363-369
    • /
    • 2005
  • This paper presents the integrated technique of water quality analysis and Geographic Information System(GIS) for assessing the variation of free chlorine residuals by water temperature and supply distance in Sangri water supply system in Daegu. GIS was utilized for mapping projectmap, extraction of a pipeline route, and supply distance. Free chlorine residual is analyzed every month for appraising the seasonal variation. As a result, free chlorine residuals are affected both water temperature and water supply distance, and it becomes worse as water temperature and water supply distance is increased. To maintain 0.4mg/l of free chlorine residual, initial dose concentration should be over 1.85mg/l in summer.

활성점에 흡착된 잔존 chlorine이 $Pt/HxMoO_3$ 생성에 미치는 영향 (Effect of an Adsorbed Residual Chlorine at Adlineation Sites over Formation of $Pt/HxMoO_3$)

  • Jin Gul, Kim;Seong-Soo, Kim
    • 한국산학기술학회논문지
    • /
    • 제5권4호
    • /
    • pp.282-285
    • /
    • 2004
  • Pt/MoO₃로의 수소 이동 속도론은 소성 온도에 따라 변하는 잔존 Cl량에 의하여 영향을 받았다. 선택적 CO화학흡착 법을 사용하여 소성 온도의 증가에 다른 Pt표면적의 감소를 측정하였다. 50℃등온 실험에서 소성 후에 Cl 량의 빠른 감소 현상을 규명하기 위하여 여러 특성화 분석을 실시하였다. Pt결정 표면에서 잔존 Cl 량의 감소는 MoO₃로의 수소 공급을 증가시켰고, 수소 흡착 속도론을 조절하였다.

  • PDF