• 제목/요약/키워드: residual chlorine

검색결과 192건 처리시간 0.02초

과일류의 염소 소독 방법에 따른 이화학적 및 관능적 품질 특성 변화 (Changes in Physicochemical and Sensory Properties of Fruits as Affected by Chlorine Sterilization)

  • 박종숙;남은숙;박신인
    • 한국식품영양학회지
    • /
    • 제21권4호
    • /
    • pp.499-509
    • /
    • 2008
  • The purpose of this study was to investigate the changes in physicochemical and sensory properties of raw fruits during washing and chlorine treatments. Strawberry and banana were pre-prepared at different concentration of chlorinated water(0 ppm, 50 ppm and 100 ppm), immersion time(3 min and 5 min), and number of post-rinsing(1 time, 2 times and 3 times). The physicochemical properties such as pH, sugar contents, residual chlorine contents, color values and hardness of the fruits were analyzed, and the sensory quality were evaluated throughout the sterilization treatment process. After washing strawberry with 100 ppm chlorinated water and 3 times of post-rinsing, pH and residual chlorine contents were showed a little difference, while sugar contents, hardness, and color values(L, a and b) were reduced. In case of banana, pH, sugar contents and residual chlorine contents were not affected, and hardness and L color value were reduced. However, a and b color values of banana were gradually increased as the development of brown discoloration. Sensory properties of the samples were affected by the chlorine sterilization treatment. In overall acceptance, strawberry and banana treated with 100 ppm chlorinated water showed the lowest scores among treatments. Therefore it could be suggested that the application of 50 ppm chlorinated water for $3{\sim}5$ minutes with over 3 times of post-rinsing was the effective pre-preparation method without affecting the quality of the fruits.

급배수시스템에서 잔류염소 농도 균등화를 위한 재염소 처리 (Rechlorination for residual chlorine concentration equalization in distribution system)

  • 김진근;한지안
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.91-101
    • /
    • 2014
  • Three water treatment plants(WTPs) in Jeju island whose source water have different characteristics from those of the mainland of Korea were investigated. Coefficients of bulk water decay($k_b$) of free chlorine at $5^{\circ}C$ for ES, GJ, NW WTPs were $-0.003hr^{-1}$, $-0.002hr^{-1}$ and $-0.001hr^{-1}$ respectively based on bottle tests. To simulate the free chlorine variations in the distribution system using EPANET, ES WTP was chosen. Free chlorine concentrations of several sites were less than the drinking water quality standards(i.e., 0.1 mg/L); E5(0.03 mg/L), E6(0.02 mg/L), W21(0.02 mg/L) and W25(0.03 mg/L). To maintain more than 0.1 mg/L of free chlorine in the distribution system, at least 1.9 mg/L of chlorine was needed at the WTP, which suggested rechlorination was needed to supply palatable tap water to customers. Two sites, one that diverged into E5 and E6 in the east-line and another located before E21 in the west-line were selected for the appropriate rechlorination locations. The recommended rechlorination dosages were 0.42 mg/L for the east and 0.27 mg/L for the west. The simulated results indicated that the free chlorine could be reduced to 0.4 mg/L at the WTP with rechlorination, and taps with excessive free chlorine could be more stabilized(i.e., 0.1~0.4 mg/L).

Pilot 규모의 모의 관망에서의 염소 농도 예측 (Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System)

  • 김현준;김상현
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

수질기준 법제화에 따른 물놀이형 수경시설의 수질관리방안 연구 (A Study on Water Quality Management Methods of Waterscape Facilities in Accordance Legislation of Water Quality Criteria)

  • 나경호;정주용;김지수;변주형
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.487-493
    • /
    • 2017
  • This study was conducted to propose measures of water quality management as the water criteria for waterscape facilities which have been highlighted as alternatives to wading pools in summer season was legislated. The number of public waterscape facilities has reached 290 sites in Gyeounggi province and 971 sites in South Korea in 2017. The water tank capacity of 80.3 % public waterscape facilities was less than $100m^3$. Facilities with disinfection system were only 6.5 % and facilities with filtration function were also very low at 6.9 %. Most of the waterscape facilities, about 93%, are expected to be vulnerable to complying with revised water quality criteria because they have to be disinfected by handling. Chlorine disinfectants, which are more persistent than ozone or ultraviolet sterilization methods, are more preferred. However, care should be taken when adding disinfectans because hypochlorous acid, which is an effective component of chlorine disinfectant, remains after the disinfection, but it is easily decomposed with time. For this study, ${\bigcirc}{\bigcirc}$ park floor fountain with a capacity of $63m^3$ was selected and the amount of free residual chlorine concentration was measured by injecting a certain amount of chlorine bleach. As a result, it took 5 hours to decrease from the water quality standard of 4 mg/L to 0.04 mg/L. If the waterscape facility is operated for 7 to 8 hours, the chlorine bleach should be re-injected after 5 hours. In addition, the problem of pH increase due to the input of chlorine disinfectant is expected, and the neutralization method using vinegar was proposed.

수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과 (Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems)

  • 고경훈;권지향;김인자;임우혁
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

가상의 물 수요곡선에 따른 수충격에 의한 염소농도변동 모의연구 (Simulation of chlorine decay by waterhammer in water distribution system based on hypothetical water demand curve)

  • 백다원;김현준;김상현
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.107-113
    • /
    • 2018
  • Maintaining adequate residual chlorine concentration is an important criteria to provide secure drinking water. The chlorine decay can be influenced by unstable flow due to the transient event caused by operation of hydraulic devices in the pipeline system. In order to understand the relationship between the transient event and the chlorine decay, the probability density function based on the water demand curve of a hypothetical water distribution system was used. The irregular transient events and the same number of events with regular interval were assumed and the fate of chlorine decay was compared. The chlorine decay was modeled using a generic chlorine decay model with optimized parameters to minimize the root mean square error between the experimental chlorine concentration and the simulated chlorine concentration using genetic algorithm. As a result, the chlorine decay can be determined through the number of transients regardless of the occurrence intervals.

AlCu 플라즈마 식각후 Al 결정입계에서 Al 부식현상 (Al corrosion phenomena on the Al grain boundary after AlCu plasma etching)

  • 김창일;권광호;윤선진;김상기;백규하;남기수
    • 전자공학회논문지A
    • /
    • 제33A권12호
    • /
    • pp.47-52
    • /
    • 1996
  • Cl-based gas chemistry is generally used to etching for al alloy metallization. After the etching of Al alloy with Cl-based gas plasma, residual chlorine on Al alloy reacts with H$_{2}$O due to air exposure and results in Al corrosion. In this study, the corrosion phenomena of Al wer examined with XPS(X-ray photoelectron spectroscopy) and SEM (scanning electorn microscopy). It was confirmed that chlorine mainly existed at the grian boundary of Al alloy after plasma etching of Al alloy with cl-based gas chemistry and Al corrosion was largely generated at the grain boundary of Al alloy. And residual chlorine was passivated by sulfur and fluorine which were generated by SF$_{6}$ plasma. These effects of passivation reduced the Al corrosion due to air exposure.

  • PDF

반응성 이온 식각후 AlCu막의 부식현상 (The corrosion phenomena of AlCu films after reactive ion etching)

  • 김창일;권광호;김상기;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.252-255
    • /
    • 1996
  • Cl-based gas chemistry is generally used to etching for Al alloy metallization. After the etching of Al alloy with Cl-based gas plasma, residual chlorine on Al alloy reacts with $H_2O$ due to air exposure and results in Al corrosion. In this study, the corrosion Phenomena of Al were examined with XPS(X-ray photoelectron spectroscopy) and SEF(Scanning electron microscopy). It was confirmed that chlorine mainly existed at the grain boundary of Al alloy after plasma etching of Al alloy with Cl-based gas chemistry and Al corrosion was largely generated at the grain boundary of Al a1loy. And residual chlorine was passivated by sulfur and fluorine which were generated by SF$_{6}$ plasma. These effects of passivation reduced the Al corrosion due to air exposure.e.

  • PDF

모형 수도관에서 염소와 모노클로라민에 의한 생물막 제거 특성 비교 (Comparison of Biofilm Removal Characteristics by Chlorine and Monochloramine in Simulated Drinking Water Distribution Pipe)

  • 박세근;최성찬;김영관
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.26-33
    • /
    • 2006
  • 본 연구에서는 염소와 모노클로라민을 이용하여 생물막이 제거되는 특성을 알아보았다. 염소와 모노클로라민을 0.5, 1.0, 2.0 mg/L의 농도로 잔류시킨 수돗물을 생물막이 형성되어 있는 모형 수도관에 연속적으로 공급하고, 관 표면으로부터 부착성 HPC와 biomass를 측정하였다. 염소는 생물막을 구성하는 미생물의 비활성화와 표면으로부터 생물막 matrix를 제거하는데 높은 효과를 나타낸 반면에 모노클로라민은 생물막 matrix를 제거하는데 염소보다 상대적으로 낮은 효율을 나타냈다. 특히 모노클로라민을 이용한 소독 처리에서는 세균과 EPS가 결합된 생물막 matrix가 관 표면으로부터 대부분 제거되지 않은 상태로 존재하였다. 비록 2.0 mg/L의 잔류염소가 생물막 제거에 높은 효과를 보였지만, 관 표면에는 여전히 낮은 수준(<10 $CFU/cm^2$ as 부착성 HPC, <5 ${\mu}g/cm^2$ as biomass)의 생물막이 잔류하고 있었다. 생물막의 제거 특성을 평가하는데 있어서 biomass의 측정이 효과적인 수단인 것으로 판단되었다.

유리염소 측정을 위한 일회용 스트립 센서 (Disposable Strip-type Sensors for Detection of Free Chlorine)

  • 김승기;강태영;차근식;남학현;신재호
    • 전기화학회지
    • /
    • 제15권4호
    • /
    • pp.242-248
    • /
    • 2012
  • 수질 분석에서 염소 소독제 잔류량 측정은 세균학적 안전성 확보와 염소의 과다 주입을 억제하기 위한 수단으로 매우 중요한 의미를 갖는다. 이러한 휴대용 잔류염소 측정기 개발을 위한 일회용 유리염소 스트립 센서를 스크린 프린팅 기술을 이용한 탄소 전극으로 제작하였다. 탄소 전극은 금과 백금 전극에 비해 결합염소(특히 $NH_2Cl$) 방해종에 대한 영향이 적었으며, -0.3 V(vs. Ag/AgCl) 인가전위에서 유리염소에 대해 안정한 감응성을 나타냈다. 이렇게 제작된 탄소 전극에 모세관현상으로 일정량의 시료를 재현성 있게 도입할 수 있는 유로구조를 갖는 일회용 스트립센서로 제작하였고, 잔류 유리염소의 분석에 적용하였다.