• 제목/요약/키워드: residual chlorine

검색결과 192건 처리시간 0.023초

합성세제의 오염과 상수정수처리에 의한 그 제거효과에 관한 조사연구 (Studies on Pollution and Reduction of Synthetic Detergents by Tap Water Treatment)

  • 권숙표;정용;심길순
    • 약학회지
    • /
    • 제21권4호
    • /
    • pp.200-210
    • /
    • 1977
  • This investigation was undertaken from February 1976 to September 1976. The detergents in municipal sewages from the Chung Kae Stream, Ahn Yang Stream, and Bong Won Stream were determined at 1.5ppm, 0.93ppm, and 3.36ppm in average respectively. The concentrations of detergents determined in the Han river were 0.013ppm of Kwang Na Ru, 0.11ppm of Duk Do, 0.370ppm of Bo Kwang Dong, and 0.285ppm of Ka Yang Dong basin respectively. And the potable waters of Sung Book Ku and Sung Dong Ku from Ku Eu water pumping station located up-stream of the Han river were less polluted at 0.045ppm and 0.037ppm in average. Young Deung Po Ku and Su Dae Moon Ku had been relatively polluted at 0.181ppm and 0.133ppm. The coagulant, alum [$Al_{2}(SO_{4})_{3}$] could eliminated the small amount of detergent by coagulation. The eliminated rates were about 13% by 5ppm and 22.7% by 20ppm of aluminum sulfate in sewage contained 10ppm of turbidity. The sand and the charcoal adsorbed some detergent as the following Langmuir's equations: For the charcoal, m/x=0.029.$\times$1/Ce-11.43 For the charcoal, m/x=2.705log1/Ce-5.46 Where m: amount of snad and active carbon used(g) x: amount of detergent adsorbed from liquid(g) Ce:concentration in the liquid at equilibrium(miles) The adsorption effect of sand would be neglected. In the low concentration of detergent solution, one gram of active carbon adsorbed 0.263g of detergent. It was determined that one gram of chlorine reduced 5.5g pf DBS om keeping up 0.2ppm of residual chlorine by disinfection process with chlorine compound.

  • PDF

도계처리 단계별 도체와 처리수의 세균오염 및 염소처리 효과 (Efficacy of Chlorine for Reducing Bacterial Populations and Bacteriological Contamination on Carcass and Treatment Water at Different Stage of Poultry Processing)

  • 이철현;변유성;황보원;조광제;강호조
    • 한국동물위생학회지
    • /
    • 제20권2호
    • /
    • pp.169-175
    • /
    • 1997
  • This study was carried out to assess the effect of the chlorine treatment into water for processing chicken products in each stage of slaughtering, with a special viewpoint related with reducing the viable number of microorganisms by which the water and the chicken body were contaminated. The mean bacterial number on chicken samples after picking process was log5.37$\pm$0.20~5.84$\pm$0.160CFU/$\textrm{cm}^2$. When assessed by standard plate count method, it was the higher one than any other processing stage in which eviscerating, pinning, packaging, and chilling was followed in order of the mean bacterial number. The coliform bacterial numbers on carcasses after sampling from different processing stages were log2.11$\pm$0.63~2.88$\pm$0.25MPN/$\textrm{cm}^2, which show almost similar numbers in each processing stage. But, after chilling process the number was decreased slightly. The bacterial counts in the water for scalding and chilling showed log3.43 $\pm$ 0.59~5.06$\pm$0.21 and log4.30$\pm$0.21~6.62$\pm$0.33CFU/$m\ell$, respectively. In the coliform counts for the water taken out from the 2nd chilling tank, the number was log1.97$\pm$0.35~2.91$\pm$0.22MPN/$m\ell$ which showed higher than those of the 1st and the 3rd chilling tank water. The effect of chlorination in reducing the bacterial numbers was accepted at the residual chlorine concentration of 1$m\ell$/$\ell$by showing the reduction from $10^8$ to $10^4$CFU level and the numbers were decreased less than 10CFU at the concentration of 5mg/$\ell$, when assessed by viable cell counts. In conclusion, these results suggested that chlorination In chilling water with final concentration of 5mg/$\ell$was strongly recommended to reduce the bacterial numbers on final chicken products.

  • PDF

기존 정수장 이산화염소 시범도입 사례연구 (A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant)

  • 이송희;이병두;김진근;석관수;이정택
    • 대한환경공학회지
    • /
    • 제27권1호
    • /
    • pp.115-119
    • /
    • 2005
  • 소독부산물에 대한 수질기준이 강화됨에 따라 외국은 물론 국내 정수장에서도 강화응집(Enhanced Coagulation), 대체소독제 사용과 오존/활성탄 등의 고도정수처리공정 등을 도입하여 운영중이거나 도입을 계획하고 있다. 국내에서는 1991년도 낙동강페놀오염사고 전후로 26개 정수장에 이산화염소 발생기가 설치되었으나 실공정에서 축적된 운영자료는 거의 없는 실정이다. 본 연구는 홍수기 특정시기에만 소독부산물이 높게 검출되는 A정수장에 이산화염소 발생기를 설치하여 1년간 운영자료를 토대로 수질개선효과 운영관리상의 문제점과 향후 기존 정수장에서 이산화염소 공정도입시 고려하여야 할 내용을 정리하였다. 이산화염소에 의하 소독부산물 저감효과는 전체공정에서 $30{\sim}40%$ 정도였으나, 2-MIB, Geosmin의 제거율은 10% 이내였다. 이산화염소 부산물이 클로라이트 클로레이트 발생량은 이산화염소 투입량의 $70{\sim}100%$ 정도였으며, 접촉시간이 경과되면서 클로레이트로 전환되는 양이 많아졌다. 또한 이산화염소와 염소를 병행사용할 경우 급배수관망에서 클로라이트와 유리잔류염소가 반응하여 이산화염소가 재생성되어 강한염소냄새(락스성) 민원이 발생될 수 있다.

목질탄화물을 이용한 미네랄수 제조에 관한 연구 (Studies on Manufacture of Mineral Water with Wood Charcoals)

  • 신수정;김병로
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권4호
    • /
    • pp.460-466
    • /
    • 2014
  • 목탄을 이용한 미네랄수의 제조가능성을 알아보기 위해, 목탄의 무기성분 용출 및 수소이온농도 및 잔류염소흡착 성능을 조사하였다. 무기성분 용출은 탄화온도가 높아짐에 따라 칼륨의 경우 용출량이 높아지나, 나머지 무기성분들의 경우 차이가 적었다. 무기성분 용출량은 각 수종에서 칼륨이 가장 높은 값을 나타냈고 다음으로는 나트륨, 칼슘 순으로 나타났고, 수종 간에는 칼륨의 경우 활엽수인 굴참남무와 버즘나무가 침엽수인 소나무, 낙엽송 및 잣나무에 비하여 현저히 높게 나타났고, 나머지 무기성분은 수종간 칼륨만큼 큰 차이는 없었으나 칼륨과 같은 경향을 나타냈다. 수소이온농도는 활엽수인 버즘나무($600^{\circ}C$의 경우 pH 8.5)와 굴참남무(pH 8.4)가 높게 나타났고, 낙엽송(pH 7.8), 소나무(pH 7.2), 잣나무(pH 7.0)가 앞의 두 수종보다 낮은 값을 나타냈다. 염소제거량은 모든 수종에서 대조구보다 높은 제거량을 나타냈고, 침엽수인 잣나무와 소나무가 활엽수인 낙엽송, 버즘나무, 굴참나무보다 높은 제거율을 나타냈다. 분말목탄과 각형목탄 간 무기성분 용출량 및 수소이온농도에서 차이가 없으므로, 목탄을 이용한 미네랄수 제조에는 분말목탄보다 제조도 용이하고, 용출 후 처리도 용이한 각형목탄이 좋을 것으로 생각된다.

Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation

  • 장영철;정권
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1114-1119
    • /
    • 2004
  • The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg $Cl_2/l$. An additional aspect of the current study was that the potential of the exoproteolytic activity (PEPA) technique was used along with a traditional so-called destructive technique in which the biofilm was scrapped off the coupon surface, resuspended, and cultivated on an R2A agar. Both techniques indicated similar trends and relative comparisons among the PDSs, yet the culturable biofilm values for the traditional method were several orders of magnitude lower than the PEPA values.

마그네슘 열환원에 의한 저응집 초미립 TiCN 분말합성 (Synthesis of Ultrafine and Less Agglomerated TiCN Powders by Magnesiothermic Reduction)

  • 이동원
    • 한국분말재료학회지
    • /
    • 제19권5호
    • /
    • pp.356-361
    • /
    • 2012
  • The ultra-fine and less agglomerated titanium carbonitride particles were successfully synthesized by magnesiothermic reduction with low feeding rate of $TiCl_4+1/4C_2Cl_4$ solution. The sub-stoichiometric titanium carbide ($TiC_{0.5{\sim}0.6}$) particles were produced by reduction of chlorine component by liquid magnesium at $800^{\circ}C$ of gaseous $TiCl_4+1/4C_2Cl_4$ and the heat treatments in vacuum were performed for 5 hours to remove the residual magnesium and magnesium chloride mixed with produced $TiC_{{\sim}0.5}$. The final $TiC_{{\sim}0.5}N_{0{\sim}0.5}$ particle with near 100 nm in mean size and high specific surface area of $65m^2/g$ was obtained by nitrification under nitrogen gas at $1,150^{\circ}C$ for 2 hrs.

수돗물속 생물막 형성의 초기 세균 (Initial Bacterial Groups in the Development of Biofilm in Drinking Water)

  • 이동근
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.428-433
    • /
    • 2007
  • To clarify the pioneer group in the development of biofilms in high chlorine residual water, a semi-pilot model system was operated and 16S rDNA V3 targeted PCR-DGGE was submitted. Biofilm formation occurred rapidly in the model of a drinking water distribution system. It reached $10^3\;CFU/cm^2$ or more on the surface of stainless steel, PVC, and galvanized iron in chlorinated (1.0 mg/l) water within a week. Within a week, uncultured Proteobacteria- and Bacillales group-like sequences were detected and Sphingomonas-like sequences were identified from all season and all pipe materials tested. Hence Sphingomonas species were regarded as the potential pioneer group in the development of biofilm in drinking water and this results would be useful for the prevention of biofilm formation and safety of drinking tap water.

Al(Cu 1%)막의 플라즈마 식각후 부식 억제를 위한 $SF_6$ 처리시 fluorine passivation 효과 (The Effects of Fluorine Passivation on $SF_6$ Treatment for Anti-corrosion after Al(Cu 1%) Plasma Etching)

  • 김창일;권광호;백규하;윤용선;김상기;남기수
    • 한국전기전자재료학회논문지
    • /
    • 제11권3호
    • /
    • pp.203-207
    • /
    • 1998
  • After etching Al-Cu alloy films using $SiCl_4/Cl_2/He/CHF_3$ plasma, a corrosion phenomenon on the metal surface has been studied with XPS (X-ray photoelectron spectroscopy) and SEM (Scanning electron microscopy). In Al-Cu alloy system, the corrosion occurs rapidly on the etched surface by residual chlorine atoms. To prevent the corrosion, the $SF_6$ plasma treatment subsequent to the etch has been carried out. A passivation layer is formed by fluorine-related compounds on etched Al-Cu alloy surface after $SF_6$ treatment, and the layer suppresses effectively the corrosion on the surface as the RF power of $SF_6$ treatment increases. The corrosion could be suppressed successfully with $SF_6$ treatment in the RF power of 150watts.

  • PDF

수돗물 신뢰도 향상을 위한 품질 인증 제도 도입 (Introduction of Water Quality Certification System for Confidence Improvement of Tap Water)

  • 김진근
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.

국내 상수관로에 대한 THM 발생 예측모델의 적용 (Application of THM Predictive Model in Water Distribution System)

  • 이두진;김영일;손진식
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.3-11
    • /
    • 2007
  • THM models have been developed in several researchers in order to better understand and manage the presence of THM in water distribution system. Several developed models were demonstrated in this study for estimating THM concentrations in target water distribution system. In order to investigate the performance of developed THM models, lab and field test were investigated. Predicted THM concentrations by all kind of models were showed good correlation with observed values. When the developed models were compared with lab and field test, the Rodriguez model during tested models was most predictive than the other models.