• 제목/요약/키워드: residual RMs

검색결과 40건 처리시간 0.025초

Self-blast형 $SF_6$ 가스 차단기의 노즐용삭 분석 (Analysis on the Mass Loss in Self-blast type $SF_6$ Gas Circuit Breaker)

  • 정영우;배채윤;안희섭;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1422-1423
    • /
    • 2006
  • In our study, the PTFE nozzle ablation in the high-voltage self-blast type $SF_6$ gas circuit breaker was investigated. The test circuit breaker has the structure that the pin electrode is moving and the pressure reservoir volume and the dimension is almost same as commercial 145kv 40kA circuit breaker for similar result in real circuit breaker. The variation of current and arcing time was the range of $36kA_{rms}$(symmetry) - $40kA_{rms}$(asymmetry) and 10-16 ms. From the measured data the tendecy of the mass loss of the nozzle to current load and arc energy was estimated. In this process, the distance from the arc to nozzle(PTFE) surface, area which was exposed to arc and stroke contour was considered. These results will be used to enhance the accuracy of the computational fluid dynamics analysis in circuit breaker and estimate the residual life time of a circuit breaker.

  • PDF

탄성파 응용기술에 의한 CFRP 복합재료의 저속충격 손상역의 미시적 거동 특성 탐지 (DETECTION OF MICROSCOPIC BEHAVIOR OF LOW VELOCITY IMPACT DAMAGED CFRP LAMINATE UNDER TENSILE LOADING BY ELASTIC WAVES)

  • 이준현;권오양;이승석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.650-655
    • /
    • 1993
  • Carbon/epoxy composite(CFRP) coupons previously damaged by low velocity impact were tested under static tensile loading and microscope progress of damage was characterized by ultrasonic C-scan, Scanning Acoustic Microscopy (SAM) and Acoustic Emission(AE) techniques which were based on the application of elastic waves. The degress of impact damage has been correlated with the AE activity during monotonic or loading/unloading tensile testing as well as the result of ultrasonic test. The coupons were subjected to impact velocities ranged from 0.71 to 2.17 m/sec, which introduced the amount of damage rated as 0%, 10%, 30%, and 50% with reference to the total absorbed energy at fracture. Special attention was paid to determine optimal AE parameters to characterize the microscopic fracture process and to predict the residual strength of composite laminates. AE RMS voltage during the early stage of tensile loading was found an effective parameter to quantify the degree of impact damage. It was also found that the Felicity ratio is closely related to the stacking sequence and the residual strength of the CFRP laminates.

  • PDF

가스 하이드레이트 부존층의 하부 경계면을 규명하기 위한 심도영역 탄성파 구간속도 분석 (Seismic interval velocity analysis on prestack depth domain for detecting the bottom simulating reflector of gas-hydrate)

  • 고승원;정부흥
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.638-642
    • /
    • 2005
  • For gas hydrate exploration, long offset multichannel seismic data acquired using by the 4km streamer length in Ulleung basin of the East Sea. The dataset was processed to define the BSRs (Bottom Simulating Reflectors) and to estimate the amount of gas hydrates. Confirmation of the presence of Bottom Simulating reflectors (BSR) and investigation of its physical properties from seismic section are important for gas hydrate detection. Specially, faster interval velocity overlying slower interval velocity indicates the likely presences of gas hydrate above BSR and free gas underneath BSR. In consequence, estimation of correct interval velocities and analysis of their spatial variations are critical processes for gas hydrate detection using seismic reflection data. Using Dix's equation, Root Mean Square (RMS) velocities can be converted into interval velocities. However, it is not a proper way to investigate interval velocities above and below BSR considering the fact that RMS velocities have poor resolution and correctness and the assumption that interval velocities increase along the depth. Therefore, we incorporated Migration Velocity Analysis (MVA) software produced by Landmark CO. to estimate correct interval velocities in detail. MVA is a process to yield velocities of sediments between layers using Common Mid Point (CMP) gathered seismic data. The CMP gathered data for MVA should be produced after basic processing steps to enhance the signal to noise ratio of the first reflections. Prestack depth migrated section is produced using interval velocities and interval velocities are key parameters governing qualities of prestack depth migration section. Correctness of interval velocities can be examined by the presence of Residual Move Out (RMO) on CMP gathered data. If there is no RMO, peaks of primary reflection events are flat in horizontal direction for all offsets of Common Reflection Point (CRP) gathers and it proves that prestack depth migration is done with correct velocity field. Used method in this study, Tomographic inversion needs two initial input data. One is the dataset obtained from the results of preprocessing by removing multiples and noise and stacked partially. The other is the depth domain velocity model build by smoothing and editing the interval velocity converted from RMS velocity. After the three times iteration of tomography inversion, Optimum interval velocity field can be fixed. The conclusion of this study as follow, the final Interval velocity around the BSR decreased to 1400 m/s from 2500 m/s abruptly. BSR is showed about 200m depth under the seabottom

  • PDF

적응광학계용 37채널 SiC 변형거울을 이용한 파면 보상 (Wavefront Compensation Using a Silicon Carbide Deformable Mirror with 37 Actuators for Adaptive Optics)

  • 안교훈;이혁교;이호재;이준호;양호순;김학용
    • 한국광학회지
    • /
    • 제27권3호
    • /
    • pp.106-113
    • /
    • 2016
  • 본 논문에서는 37채널을 갖는 적응광학계용 SiC(Silicon Carbide) 변형거울의 파면 보상 성능 검증에 관한 내용을 다룬다. 컴퓨터 시뮬레이션을 통해 SiC 변형거울의 파면 보상 성능을 예측하였고, 실제 closed-loop 적응광학계를 구성하여 파면 보상 성능을 확인 하였다. Closed-loop 적응광학계는 광원, 위상판, SiC 변형거울, 고속 샥-하트만 센서 그리고 제어용 컴퓨터로 구성되어있다. 회전하는 위상판에 의해 왜곡된 파면을 샥-하트만 센서로 측정하고, SiC 변형거울을 이용하여 왜곡된 파면을 보상해주는 시스템이다. 결과적으로 closed-loop 적응광학계에서 500 Hz의 속도로 PV(Peak-to-Valley) $0.3{\mu}m{\sim}0.9{\mu}m$, RMS(Root-Mean-Square) $0.06{\mu}m{\sim}0.25{\mu}m$의 왜곡된 파면을 PV $0.1{\mu}m$, RMS $0.03{\mu}m$이하로 보상시킬 수 있었다.

Influence of Carbonization Conditions in Hydrogen Poor Ambient Conditions on the Growth of 3C-SiC Thin Films by Chemical Vapor Deposition with a Single-Source Precursor of Hexamethyldisilane

  • Kim, Kang-San;Chung, Gwiy-Sang
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.175-180
    • /
    • 2013
  • This paper describes the characteristics of cubic silicon carbide (3C-SiC) films grown on a carbonized Si(100) substrate, using hexamethyldisilane (HMDS, $Si_2(CH_3)_6$) as a safe organosilane single precursor in a nonflammable $H_2$/Ar ($H_2$ in Ar) mixture carrier gas by atmospheric pressure chemical vapor deposition (APCVD) at $1280^{\circ}C$. The growth process was performed under various conditions to determine the optimized growth and carbonization condition. Under the optimized condition, grown film has a single crystalline 3C-SiC with well crystallinity, small voids, low residual stress, low carrier concentration, and low RMS. Therefore, the 3C-SiC film on the carbonized Si (100) substrate is suitable to power device and MEMS fields.

Deposition of $SiC_xN_y$ Thin Film as a Membrane Application

  • Huh, Sung-Min;Park, Chang-Mo;Jinho Ahn
    • 마이크로전자및패키징학회지
    • /
    • 제8권1호
    • /
    • pp.39-43
    • /
    • 2001
  • $SiC_{x}N$_{y}$ film is deposited by electron cyclotron resonance plasma chemical vapor deposition system using $SiH_4$(5% in Ar), $CH_4$ and $N_2$. Ternary phase $SiC_{x}N$_{y}$ thin film deposited at the microwave power of 600 W and substrate temperature of 700 contains considerable amount of strong C-N bonds. Change in $CH_4$flow rate can effectively control the residual film stress, and typical surface roughness of 34.6 (rms) was obtained. Extreme]y high hardness (3952 Hv) and optical transmittance (95% at 633 nm) was achieved, which is suitable for a LIGA mask membrane application.

  • PDF

웹 기반 CFD s/w용 GUI 프로세서의 구현 (IMPLEMENTATION OF FULL WEB-BASED GRAPHIC USER INTERFACE PROCESSOR FOR CFD SOFTWARE)

  • 막슈다 쥬래바;에브게니 이바너프;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 추계 학술대회논문집
    • /
    • pp.121-125
    • /
    • 2004
  • The preprocessor - solver - postprocessor software for 2D/Axisymmetric CSCM Upwind Flux Difference Splitting Navier-Stokes code has been developed for undergraduate educational purpose. This computational fluid dynamics (CFD) software allows students to setup, solve, visualize and control dynamically server for their own fluid problems via Internet. The preprocessor Is capable of generating geometry and grid, initial solution data and required solver control parameters. The postprocessor shows vector plot and contour plot with different options while residual plot shows root-mean-square (RMS) error history graphically and retrieves the data from solver interactively. Special feature of the preprocessor is grid generation part which is based on MFC/Visual C++ application and FORTRAN single block grid generator process. Many users can access solver via Internet from client computers and solve desired problems using locally installed pre- and postprocessor and remote powerful solver part.

  • PDF

A NEW REFERENCING METHOD FOR THE ARRAY ON-THE-FLY OBSERVATION

  • CHUNG EUN JUNG;KIM HYORYOUNG;RHEE MYUNG-HYUN
    • 천문학회지
    • /
    • 제38권1호
    • /
    • pp.17-22
    • /
    • 2005
  • In this paper, we suggest a new referencing method for the array On-The-Fly(OTF) observations in radio astronomy. To reduce the baseline residual, we have proposed and evaluated a new referencing method which uses the source free regions in the observed frame as references. These new references have small ${\Delta}$t and ${\Delta}$x, the time and position differences between the source and the references, and the systematic problems w~re improved by using this new referencing method. The curved baseline residuals were straightened and the rms was reduced to 17 mK. This new referencing method is expected not only to make possible to take more stable data for the array OTF observation of external galaxies but also to save the observation and data reduction time.

Comparison of Mathematical Models Applied to F1 Dairy Sheep Lactations in Organic Farm and Environmental Factors Affecting Lactation Curve Parameter

  • Angeles-Hernandez, J.C.;Albarran-Portillo, B.;Gomez Gonzalez, A.V.;Pescador Salas, N.;Gonzalez-Ronquillo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권8호
    • /
    • pp.1119-1126
    • /
    • 2013
  • The objective of this study was to compare the goodness of fit of four lactation curve models: Wood's Gamma model (WD), Wilmink (WL), and Pollott's multiplicative two (POL2) and three parameters (POL3) and to determine the environmental factors affecting the complete lactation curve of F1 dairy sheep under organic management. A total of 5,382 weekly milk yields records from 150 ewes, under organic management were used. Residual mean square (RMS), determination coefficients ($R^2$), and correlation (r) analysis were used as an indicator of goodness of fit for each model. WL model best fitted the lactation curves as indicated by the lower RMS values (0.019), followed by WD (0.023), POL2 (0.025) and POL3 (0.029). The four models provided total milk yield (TMY) estimations that were highly correlated (0.93 to 0.97) with observed TMY (89.9 kg). The four models under estimated peak yield (PY), whereas POL2 and POL3 gave nearer peak time lactation estimations. Ewes lambing in autumn had higher TMY and showed a typical curve shape. Higher TMY were recorded in second and third lambing. Season of lambing, number of lambing and type of lambing had a great influenced over TMY shaping the complete lactation curve of F1 dairy sheep. In general terms WL model showed the best fit to the F1 dairy sheep lactation curve under organic management.

마산만의 해수유동에 관하여 (Variability of Current Velocities in Masan Inlet)

  • 김종화;장선덕;김삼곤
    • 한국수산과학회지
    • /
    • 제19권3호
    • /
    • pp.274-280
    • /
    • 1986
  • 대, 소조기에 마산만에서 연속관측한 자료를 사용하여 만구 단면의 유속 변동특성을 구명하기 위하여 net velocity와 RMS속도의 등양선 및 순 유출입량을 계산하여 검토하였다. 최강유속은 수도 중앙과 서부의 4m 이하의 표층에서 나타나고, 최대 유입속도 24cm/sec 최대 유출속도는 15 cm/sec이다. 최강유속 시간임에도 불구하고 4m 이심에서는 유속이 약하여 $0{\sim}2cm/sec$에 불과하다. 만구 단면의 가장자리의 상층에 역류가 존재한다. net velocity는 비가 오지 않은 대조기의 경우 유출유속은 만구단면 서부에서 나타나며, 유입유속은 단면 동부에서 나타난다. 비온 직후의 소조기에는 이와 정반대로 흐른다. RMS속도의 최대 세기는 대조기에 $11.3{\sim}15.0cm/sec$, 소조기에 $7{\sim}10.3cm/sec$로서 단면 서부의 표층에 있으며, 매 조석주기마다 거의 동일위치에서 계속 존재한다. 순 통과유량은 건기에 $-39.7m^3/sec$, 우기 $-170m^3/sec$로서 유출이 탁월하다. 항유성분은 건기에는 조석잔차류가 우세하지만, 소조기의 강우시에는 밀도류가 우세한 것으로 추리된다.