• Title/Summary/Keyword: required supply rate

Search Result 237, Processing Time 0.043 seconds

Design and Implementation of a RFID Transponder Chip using CMOS Process (CMOS 공정을 이용한 무선인식 송수신 집적회로의 설계 및 제작)

  • 신봉조;박근형
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.881-886
    • /
    • 2003
  • This paper describes the design and implementation of a passive transponder chip for RFID applications. Passive transponders do not have their own power supply, and therefore all power required for the operation of a passive transponder must be drawn from the field of the reader. The designed transponder consists of a full wave rectifier to generate a dc supply voltage, a 128-bit mask ROM to store the information, and Manchester coding and load modulation circuits to be used for transmitting the information from the transponder to the reader. The transponder with a size 410 x 900 ${\mu}$m$^2$ has been fabricated using 0.65 ${\mu}$m 2-poly, 2-metal CMOS process. The measurement results show the data transmission rate of 3.9 kbps at RF frequency 125 kHz.

A Configuration of DLC(Direct Load Control) Using Internet Communication and Load Control Method (인터넷을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법)

  • Lee, Jae-Kyung;Kim, In-Soo;Kim, Hyeong-Jung;Lee, Seoung-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.60-64
    • /
    • 2001
  • Recent recovery of the Korean economy drives a rapid increase in utility consumption and requires more stable utility supply and maintenance. However, power location security hardship, reinforcement of international environmental regulation and a huge cost of power plant construction have increased the burden laid on the stable supply. In addition, an efficient and flexible load management is required more than any era since an increment of the rate of increase in cooling load is expected. Therefore, according as the necessity of direct load control for cooling load during the summer in Korea was on the rise, direct load control systems by Internet communication method are constructed at five commercial buildings. Based on practical load control, this study proposes various application modes and communication methods prior to extension diffusion of direct load control hereafter.

  • PDF

A Study of Design factors for Increasing Energy Production in Small Hydro power with Using Long Pipe (장대관로를 이용한 소수력 발전량 향상을 위한 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1134-1139
    • /
    • 2014
  • Recently the need for renewable energy development is expanding due to the global climate change, the environmental issues and the limited fossil energy resources. Dependence of energy on overseas is high in Korea. To resolve the environmental problems and to improve the energy independence rate, the development of renewable energy is more required. The small hydro power, one of the renewable energy resources, has been developing and operating from a long time ago. If we are new developing a small hydro power with the use existing dams and reservoirs, we will design the length of inlet pipe and the diameter suitable for it. However, in case of using the existing water supply pipe which had been designed suitable for water service, the designer has to review and check that the pipe is suitable for operating a generator. In this paper, the design of small hydro power using the existing long pipe of water supply, we suggest the optimum way to reduce the water hammer in pipe which causes the unsteady flow during the load-shutdown of generator, the generator operation plan for the stable supply of water and the design factor of determining the generator capacity through the analysis between discharge and head-loss.

Managing Within-Field Spatial Yield Variation of Rice by Site-Specific Prescription of Panicle Nitrogen Fertilizer

  • Ahn Nguyen Tuan;Shin Jin Chul;Lee Byun-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.4
    • /
    • pp.238-246
    • /
    • 2005
  • Rice yield and protein content have been shown to be highly variable across paddy fields. In order to characterize this spatial variability of rice within a field, two-year experiments were conducted in 2002 and 2003 in a large-scale rice field of $6,600m^2$ In year 2004, an experiment was conducted to know if variable rate treatment (VRT) of N fertilizer, that was prescribed for site-specific management at panicle initiation stage, could reduce spatial variation in yield and protein content of rice while increasing yield compared to conventional uniform N topdressing (UN, 33kg N/ha at PIS) method. VRT nitrogen prescription for each grid was calculated based on the nitrogen (N) uptake (from panicle initiation to harvest) required for target rice protein content of $6.8\%$, natural soil N supply, and recovery of top-dressed N fertilizer. The required N uptake for target rice protein content was calculated from the equations to predict rice yield and protein content from plant growth parameters at panicle initiation stage (PIS) and N uptake from PIS to harvest. This model· equations were developed from the data obtained from the previous two-year experiments. The plant growth parameters for the calculation of the required N were predicted non-destructively by canopy reflectance measurement. Soil N supply for each grid was obtained from the experiment of year 2003, and N recovery was assumed to be $60\%$ according to the previous reports. The prescribed VRT N ranged from 0 to 110kg N/ha with an average of 57kg/ha that was higher than 33 kg/ha of UN. The results showed that VRT application successfully worked not only to reduce spatial variability of rice yield and protein content but also to increase rough rice yield by 960kg/ha. The coefficient of variation (CV) for rice yield and protein content was reduced significantly to $8.1\%$ and $7.1\%$ in VRT from $14.6\%$ and $13.0\%$ in UN, respectively. And also the average protein content of milled rice in VRT showed very similar value of target protein content of $6.8\%$. In conclusion the procedure used in this paper was believed to be reliable and promising method for reducing within-field spatial variability of rice yield and protein content. However, inexpensive, reliable, and fast estimation methods of natural N supply and plant growth and nutrition status should be prepared before this method could be practically used for site-specific crop management in large-scale rice field.

The Effect of Sulfur/Limestone Ratio on the Efficiency of Sulfur-Utilizing Denitrification (황/석회석 충전비가 황-이용 탈질효율에 미치는 영향)

  • Shin, Hyung-Soon;Lee, Il-Su;Hwang, Yong-Yoo;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.271-280
    • /
    • 2000
  • This study was conducted to determine the applicable loading rate and to evaluate the possibility of using limestones as an alkalinity source for the removal of ${NO_3}^{-}-N$ remaining after denitrification/nitrification process with the down-flow sulfur packed bed reactor(SPBR). The pretreated sewage was fed to SPBR. Three SPBRs were filled with elemental sulfur particles and limestones and the volumetric ratios of sulfur to limestone were 0%, 12.5% and 25% for R-0%, R-12.5% and R-25%, respectively. The applicable loading rate was evaluated increasing flow rate with influent ${NO_3}^{-}-N$ concentration of 20 mg/L. For R-0% with external alkalinity supply, denitrification efficiency was greater than 96% up to loading rate of $354.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.4hr. For R-12.5% and R-25%, where alkalinity was supplied by the limestone filled in the reactor, denitrification efficiency was greater than 94% up to loading rate of $283.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.7hr. The slightly better performance of R-12.5 compared to R-25 suggests that the volumetric sulfur to limestone ratio of 12.5% was enough for the supply of alkalinity required for sulfur-utilizing denitrification. DO was appeared not showing inhibitory effect on sulfur-utilizing denitrification. The clogging of SPBR caused by the produced gas can effectively be eliminated by regular introduction of treated water in up-flow mode.

  • PDF

An Experimental Study on the Design Factors of Raw-water Supply System in Floodplain Filtration (홍수터여과에서 원수공급체계의 설계요소에 대한 실험연구)

  • Kim, Hoh-Seok;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.957-964
    • /
    • 2009
  • Sand tank experiments were performed along with on-site supplier experiments in order to obtain design factors for the raw-water supply system in floodplain filtration. Results of the sand tank experiment elucidated that the infiltration rate was approximately proportional to the soil permeability and was not significantly influenced by short periods of rest. The average daily infiltration rate calculated by taking both flood and rest periods into account increased with increasing flood period, and was observed to reach an asymptote. Under the conditions of this study, the maximum infiltration rates obtained for both Daegu and Mulgeum soils with 15 min/ 30 min of rest/flood periods were 6.3 m/day and 1.4 m/day respectively, which were 42% and 70% of their hydraulic conductivities, respectively. The process of soil filtration resulted in a gradual decrease of hydraulic conductivity; a decrease of 27% was observed for the soil of Mulgeum over a period of 8 days. From the data obtained from the supplier experiment, it was evident that the radius of the flooded area increased as the supply rate increased for soils of Gumi and Sangju, however, there was an inverse correlation between hydraulic conductivity and the rate of increase in the radius. Results also showed that the time required to cover the entire soil surface with water, in other words, the time to reach the maximum flood radius from the commencement of the water emission was as short as 3 to 4 minutes for all the soils. Also, the average infiltration rate for the entire flood period did not change significantly when the rest period was shorter than an hour.

Review of Propellant Vibration and Control of Liquid Rocket Fuselage Feeding System (액체로켓 기체공급계의 추진제 진동특성 및 제어기술 동향)

  • Cho, Nam-Kyung;Kho, Hyun-Seok;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.89-94
    • /
    • 2010
  • Fuselage propellant feeding system should supply propellants to engine with required flow rate, temperature and pressure. Propellant vibration in engine and feeding line changes feeding characteristics, and frequently inhibits to satisfy the required feeding requirements. Sloshing and POGO vibration are known to be the major vibration phenomena. Concerning sloshing and POGO, vehicle control and structural dynamics aspects are extensively studied, whereas, its effect on propellant feeding performance is not clearly understood. This paper focuses on the deviation of required feeding performance due to propellant vibration. Overall characteristics of propellant vibration and its effect on propellant supply to engine are reviewed and control mechanism for suppressing vibration is introduced.

  • PDF

Design of Optimal Water Treatment Processes based on Required Water Quality for Utilization of the Saemanguem Lake Water (새만금 담수 활용을 위한 요구수질별 최적의 수처리 방안 연구)

  • Choi, Kyung-Sook;Lee, Kwang-Ya
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.169-178
    • /
    • 2012
  • This study was aimed at providing optimal water treatment processes based on various required water quality for utilization of the Saemangeum lake water as water supply alternatives to this area. Various water treatment methods were considered for investigation there characteristics, pollution removal rate, pros and cons in order to select appropriate water treatment processes satisfying the required water quality for different purposes. As results, the FDA system for SS, turbidity, BOD removals, UV treatment for coliform, BOD removals, FNR process for T-N, T-P removals, and ECRS process for desalination purpose were found to be better methods in senses of removal efficiency, operation and maintenance. Case studies were provided with cost analysis for field applications in the Saemangeum area.

The Performance Evaluation of Plate Type STR Reactor with Variation of S/C Ratio and Fuel Supply (연료 공급 및 S/C비에 따른 평판형 STR 반응기 성능 평가)

  • Kim, Hun-Ju;Heo, Su-Bin;Park, Jae-Min;Yoon, Bong-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • According to the propagation of fuel cell system, the importance of that system efficiency is being magnified. Thus, the efficiency improvement of reformer which is the important factor of fuel cell system will be required. This study has been experimentally performed to evaluated the performance of plate type STR reactor. At first, we changed fuel flow rate (2, 3 and 4 l/min) in burner, and then we measured a proportion of hydrogen in produced gas through the STR reactor by G.C for evaluating the performance of plate type STR reactor in various fuel supply conditions. And we changed S/C ratio (2 and 4) and measured a proportion of hydrogen in produced gas through the STR reactor. As a results, condition at fuel flow rate 2 and 3 l/min could not be supplied amount of heat for STR sufficiently. Condition at fuel flow rate 4 l/min could supplied a heat excessively. And condition at S/C ratio 2, reaction occurred insufficiency. But condition at S/C ratio 4 was excess. From above, we found the optimum conditions that were fuel rate 3.5 l/min and S/C ratio 3.

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.