• Title/Summary/Keyword: representative pulse wave

Search Result 8, Processing Time 0.025 seconds

Study on the Selection of Representative Pulse Wave

  • Kim, Jong-Yeol;Shin, Sang-Hoon
    • The Journal of Korean Medicine
    • /
    • v.29 no.5
    • /
    • pp.104-110
    • /
    • 2008
  • Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

  • PDF

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.

Method for Determining the Deficient and Solid Pulse with a New Pulse Wave Parameter (새로운 맥상 파라메터를 이용한 허실맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • The pulse diagnosis is an important method in Oriental Medicine. Recently, there have been continuous attempts to replace the finger palpation by Oriental medical doctors (OMDs) by more objective tools based on machines, e.g., pulse analyzers. To improve the performance of the pulse analyzers, both the machine-appropriate interpretations for the pulse images appeared in the literature and the improvement in the repeatability and reproducibility of the measurement sensors are to be developed. As an attempt towards the transformation of the pulse images in terms of machine-appropriate language, in this work, we suggest an upgraded algorithm for the solid/deficient pulses, which are the two representative pulse images informing us how strong the pulse pressure is. It has been argued that one could determine the solid/deficient pulses by the maximum pulse pressure from pulse analyzers. However, by a clinical test, we found that the maximum pulse pressure alone is not sufficient to determine the solid/deficient pulses. In addition to the maximum pulse pressure, the mean pulse pressure averaged over for five different hold-down pressures(3-D MAC) is needed to improve the agreement with the OMD's decision for the solid/deficient pulse. We found that, among the data diagnosed with having either the solid pulse or deficient pulse by OMDs, the novel algorithm showed 86.0% diagnosis rate and 81.6% concordance rate.

Pulse wave Measurement System by analyzing a Moving Pulse Image in the Capillary Tube (모세관 맥동파 영상을 이용한 맥파 측정 시스템)

  • Lee, Woo-Beom;Choi, Chang-Yur;Hong, You-Sik;Lee, Sang-Suk;Nam, Dong-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.145-151
    • /
    • 2012
  • The pulsimeter is a representative device in the oriental medicine, which can analysis a risk factor in a cardiovascular diseases. However, most of the previous methods have the limit by the contacted sate of the brachial pulse and sensor in the measuring time, the inaccuracy of detected pulse, and the difficulty of pulse analysis. Accordingly, we propose the moving pulse image analysis based pulsimeter that can acquire a pulse of patient in real time by analyzing a moving image. then this video is shot the state change of the T.S. occurred by a pulse in capillary. In order to evaluate the performance of the our pulsimeter, we measured a respective detecting-rate about the essential 5 feature-points in the pulse analysis from the detected original pulse. As a result, the proposed method is very successful.

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

A Study on the Waveform Analysis of Left KWAN Pulse Dignosis by the Pressure (단계별(段階別) 가압(加壓)에 따른 좌관부위(左關部位) 맥파(脈波) 변화(變化))

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Kyeong-Ho;Kim, Jong-Hwan;Park, Ju-Yeon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.1
    • /
    • pp.19-35
    • /
    • 2009
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundamentals of contemporary pulse diagnosis research. To achieve certain experimental basis on traditional pulse diagnosis, we have to research the differences of pulse waveform according to pressure (in 5 level) and position (Chon, Gwan, Cheok in radial artery). As a first step, in present thesis, we tried to find the differences of pulse waveform according to pressure. Methods and Results : In this research, we analyzed seven parameters of the waveform at five levels of pressure. The parameters are E(so called 'energy', a representative of pulse strength), h1(height of percussion wave) and h2(height of subincisura). The results were as follows. 1. When we analyzed the change of the waveform according to pressure in the left Gwan, E, hl, h2 and A differed between 1st and 2nd grade, between 1st and 3rd grade, between 1st and 4th grade, between 1st and 5th grade, between 2nd and 3rd grade, between 2nd and 5th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 2. And t2, t4 differed between 1st and 2nd grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 3. W differed between 1st and 3rd grade, between 1st and 4th grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade, and between 4th and 5th grade in 95% confidence interval. 4. And h2/h1 differed between 1st and 4th grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade & between 3rd and 5th grade in 95% confidence interval. 5. There were differences between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% confidence interval. And there were differences between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% confidence interval. And were differences between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% confidence interval. Conclusions : As mentioned above, we conclude that the waveform analysis according to five grade pressure in the left Gwan shows the difference of waveform in each grade pressure.

  • PDF

Implementation of VGPO/VGPI Velocity Deception Jamming Technique using Phase Sampled DRFM (위상 샘플방식 DRFM을 이용한 VGPO/VGPI 속도기만 재밍기법 구현)

  • Kim, Yo-Han;Moon, Byung-Jin;Hong, Sang-Guen;Sung, Ki-Min;Jeon, Young-Il;Na, In-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.955-961
    • /
    • 2021
  • In modern warfare, the importance of electronic warfare, which carries out a mission that using radio wave to find out enemy information or to protect ally information, has increased. Radar jamming technique is one of the most representative techniques of EA(Electronic Attack), it disturbs and deceives enemy radar system in order to secure ally location information. Velocity deception jamming technique, which is one of the radar jamming techniques, generally operate against pulse-doppler radar which use doppler effect in order to track target's velocity and location. Velocity Deception Jamming Technique can be implemented using DRFM(Digital Radio Frequency Memory) that performs Frequency Modulation. In this paper, I describe implementation method of VGPO/VGPI(Velocity Gate Pull-Off/Pull-In) velocity deception jamming technique using phase-sampled DRFM, and verify the operation of VGPO/VGPI velocity deception jamming technique with board test under signal injection condition.