• Title/Summary/Keyword: replicas

Search Result 155, Processing Time 0.027 seconds

An Efficient Replication Scheme in Unstructured Peer-to-Peer Networks (비구조적인 피어-투-피어 네트워크상에서 효율적인 복제기법)

  • Choi Wu-Rak;Han Sae-Young;Park Sung-Yong
    • The KIPS Transactions:PartA
    • /
    • v.13A no.1 s.98
    • /
    • pp.1-10
    • /
    • 2006
  • For efficient searching in unstructured peer-to-peer systems, random walk was proposed and several replication methods have been studied to compensate for the random walk's low query success rate. This paper proposes an efficient replication scheme that improves the accuracy and speed of queries and reduces the cost by minimizing the number of replicas and by utilizing caches. In this scheme, hub nodes store only content's caches, and one of their neighbors stores the replica. By determining hubs with only limited and local information, we can adaptively generate caches and replicas in dynamic peer-to-peer networks.

Analysis of Upper Torsos Replicas of Elderly Women for Bodice Pattern

  • Shin, Hae-Kyung
    • International Journal of Costume and Fashion
    • /
    • v.3
    • /
    • pp.13-24
    • /
    • 2003
  • The purpose of this study was to examine the changes brought by the upper body form using a three-dimensional human body measurement the gypsum method. The developed plane figure was constructed using paper replica to analyze the dimensional shape of the upper torso and to be able to design clothes suitable for elderly women's physical characteristics. The characteristics are analyzed and compared with existing patterns in order to extract the components for the pattern design. The examination was carried out based on the developed plane figures of upper body surface replicas. Type 1, the bent-forward body form, has a wide gap on the shoulder. In Type 2, the gap of waist line was wide at angulus scapulae point. Type 3 was the thin body form, and the girth of the chest, front interscye breadth and back interscye breadth were more level with one another, compared to the other types. In Type 4, the bent-backward body form, there was a wide gap on front shoulder. Comparison with the developed plane figure and existed pattern, items revealed differences in significance included the front and back interscye width between the measured values of the existed patterns and the developed plane figure. Therefore, the basic components of basic bodice pattern for old women were determined in the up-bust circumference and length of the back.

A Study on Making Skirt from the standpoints of Human Engineering (Skirt 제작에 관한 인간공학적 연구 -앉는 동작을 중심으로-)

  • 이년순
    • Journal of the Korean Home Economics Association
    • /
    • v.18 no.4
    • /
    • pp.31-39
    • /
    • 1980
  • The basic pattern of skirt should be functional in addition to be fit the body. The author paid special attention to the expansion and contraction of the shell which were made the lower trunk and thigh caused by sitting motions. The replicas of the shell were taken by using a gypsum method on 1 female under 4 standardized motions; standing motion, (basic motion), sitting on the chair with flextion 90' at the hip and the knee joints sitting with dropping knees, and sitting with benting legs side wards. Those replicas obtained were developed to the patterns and changes in shape and area of those were measured. Typical displacement and transformation of the shell surface patterns were showed geographycally fig 5-1 to 5-4. mean values of expansion and constriction were obtained by measuring the shell surface on 60 female under the 4 motions. the mean values of it were showed numerically in Table 1-1 to 1-3. The following results were obtained; 1. Vertical constriction of front of the shell were observed near sulcus in guinalis, and vertical extension were near the knees. Horizontal extension were observed near the thighs and the knees. 2. Vertical constrictions of the back of the shell were observed near the knees. It seemed to be influnced the flexion angles of knee points. vertical extension were near gluteus and thighs. Horizontal constriction were small, and horizonlal extension were near gluteus. 3. The high rates of constriction and extension were found near sulcus in guinalis, glutes, and knees. 4. The rates of constriction and extension on the waist line were very low. 5. The highest values of constriction and extension were found in hip and knees.

  • PDF

Development of a Food Replica Information System and Its Applications to Community (음식모형시스템 개발 및 활용화 방안에 관한 연구)

  • 권순호;민영희;이경희;홍주영;배상수
    • Health Policy and Management
    • /
    • v.11 no.1
    • /
    • pp.37-61
    • /
    • 2001
  • In the course of this research, we developed FRIS(Food Replica Information System), which calculates calories and nutrient values of foods in a very simple and interesting manner, and experienced of application to some communities. We expect that individuals will have opportunities to raise their consciousness of food, nutrients, and healthy living by participating in FRIS. 154 kinds of commonly consumed Korean foods were selected and one serving sized food replicas, having the same shapes, size, and color as the real foods, were constructed with attached bar code labels. An application program with food replicas and bar code was also developed in order to provide information on calories and nutrient values for people's meals or selected foods based on survey results of housewives' requirements related to foods and nutrients. FRIS should be a basic tool in nutrition education and consultation. Its applicability would vary according to the nutritionist's flexibility and contents of developed application programs. Technical stability should be strengthened and more useful contents of application prograln be added to spread the use of the system. Additionally, in future research, more delicate models should be developed and an analytical method should be applied to examine the effects of FRIS to individual behavioral changes in their eating habits.

  • PDF

Evaluation of marginal fit of monolithic zirconia restoration by digital impression (디지털 방식을 이용하여 제작한 전부 지르코니아 수복물의 변연 적합도 평가)

  • Yun, Mi-Jung;Kim, So-Yeun;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.366-374
    • /
    • 2018
  • Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the conventional impression technique. Before definitive insertion, silicone replicas were produced from all twenty crowns. The silicone replicas were cut in three sections; each section was evaluated at two points. The measurement was carried out by using a measuring microscope (Olympus BX 51) and I-Solution. Data from the silicone replica scores were analyzed by Shapiro-Wilk test for normal distribution and the t-test for equality of two population's mean. All tests were performed with ${\alpha}-level$ of 0.05. Results : The average marginal gaps of monolithic zirconia restorations were $133.81{\pm}36.46{\mu}m$ for the conventional impression technique, $90.07{\pm}9.47{\mu}m$ for the digital impression technique. No statistical differences were found between the two impression techniques Conclusion : Both prostheses presented clinically acceptable results with comparing the marginal fit.

  • PDF

The effect of electrolytes on the preparation of an extraction replica in 3 wt. % Si steel (3% Si 강의 추출복제시료제조에 미치는 전해액의 영향)

  • Park, Shin-Hwa;Kim, Jae-Kwan;Kim, Jae-Nam;An, Byung-Ryang;Lee, Do-Hyung
    • Applied Microscopy
    • /
    • v.23 no.2
    • /
    • pp.1-10
    • /
    • 1993
  • The effect of electrolyte on the extraction replicas of the precipiates in 3% Si steel was investigated. Three Kinds of electrolyte, 2% Nital solution (2% nitric acid+methanol; acid solution),, Sodium Citrate solution (5% sodiumcitrate+1% KBr+0.5KI+$H_{2}O$; aqueous neutral solution) and 10% AA solution (10% acetylacetone+ 1% tetramethylammoniumchloride+methanol; non-aqueous neutral solution), were compared. The preciptiates in 3% Si steel were dissolved in 2% Nital, but they were not dissolved in the Sodium Citrate and 10% AA solution. In Sodium Citrate solution, however, large second artifacts were introduced during sample preparation. Therefore 10% AA solution was found to be most useful for the preparation of extraction replica. The electrolysis condition of a matrix and precipitates were also checked by the measurement of potential-current curve in 10% AA solution. The matrix was electrolyzed at -400mV with respect to SCE(Saturated Calomel Electrode). In contrats precipitates were electrolyzed above 300mV. Precipitates were respected to be stable in 10% AA solution in the range of $-380mV{\sim}-300mV$ usually used to prepare extraction replicas.

  • PDF

Development of the Fundamental Methodology of Lower Cup Pattern depending on 3D Shape Analysis of Breast (3차원 형상 분석을 통한 브래지어 하컵 패턴의 원리 분석)

  • Lee, Okkyung;Hong, Kyunghi;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.1
    • /
    • pp.94-105
    • /
    • 2021
  • This study analyzes the shape change of the breast according to the replica combination method of the lower cup and suggest a pattern construction for the end use purpose. To provide appropriate brassiere patterns to each individual who has various 3D shape characteristics, the ways of layout of 3D replicas were investigated as well as evaluated subjectively and objectively. As for experimental brassieres, basic replicas from the mold cup of long-run brassiere were combined into five different ways to find the appropriate lower brassiere cup pattern. Eighteen women wore experimental brassieres and their breasts were analyzed using the Geomagic Design X program (3D System, Inc., Korea). As result, the pattern that matched the vertexes of the four pieces of the replica and naturally spread the bottom part was best for raising and pushing toward the inside breasts. The fit was good in the case of a pattern in which the convex portions overlapped both sides of the four replica pieces where the vertexes and the bottom part naturally spread apart. The subjects were able to differentiate comfortably fitted brassieres and highly functional brassieres.

DISEASE FORECAST USING MACHINE LEARNING ALGORITHMS

  • HUSSAIN, MOHAMMED MUZAFFAR;DEVI, S. KALPANA
    • Journal of applied mathematics & informatics
    • /
    • v.40 no.5_6
    • /
    • pp.1151-1165
    • /
    • 2022
  • Key drive of information quarrying is to digest liked information starting possible information. With the colossal amount of realities kept in documents, information bases, and stores, in the medical care area, it's inexorably significant, assuming excessive, arising compelling resources aimed at examination besides comprehension like information on behalf of the withdrawal of gen that might assistance in independent direction. Classification is method in information mining; it's characterized as per private, passing on item toward a specific course established happening it is likeness toward past instances of different substances trendy the data collection. In pre-owned recycled four Classification algorithm that incorporate Multi-Layer perception, KSTAR, Bayesian Network and PART to fabricate the grouping replicas arranged the malaria data collection and analyze the replicas, degree their exhibition through Waikato Environment for Knowledge Analysis introduced to Java Development Kit 8, then utilizations outfit's technique trendy promoting presentation of the arrangement methodology. The outcome perceived that Bayesian Network return most elevated exactness of 50.05% when working on followed by Multi-Layer perception, with 49.9% when helping is half, then, at that point, Kstar with precision of 49.44%, 49.5% when supporting individually and PART have lesser precision of 48.1% when helping, The exploration recommended that Bayesian Network is awesome toward remain utilized on Malaria data collection in our sanatoriums.

A Freeze-fracture Study on the Odontoblast of Dental Pulp in the Rat Incisor (흰쥐 절치치수의 Odontoblast에 관한 Freeze-Fracture 연구)

  • Kim, Myung-Kook
    • Applied Microscopy
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study was to investigate the morphology and intercellular junctions of the odontoblast of dental pulp in the rat incisor by means of the freeze fracture electron microscopy. Twenty male Sprague-Dawley rats weighing $150{\sim}200g$ were used. After being anesthetized by an intraperitoneal injection of 0.5 ml sodium pentobarbital per kg in body weight(60 mg/ml) the animals were perfused with 2.5% glutaraldehyde-2% paraformaldehyde fixative in 0.1 M cacodylate buffer, pH 7.2 through the ascending aorta for one hour. The incisors were carefully extracted from the jaws and demineralized by suspending them in 0.1 M EDTA in 3% glutaraldehyde (pH 7.2) for two weeks. After demineralization, the specimens were obtained from the portion divided into five equal parts. For freeze-fracture replication, demineralized tissues were infiltrated for several hours with 10%, 25% glycerol in 0.1M cacodylate buffer as a cryoprotectant and then frozen in liquid Freon 22 and stored in liquid nitrogen. Fracturing and replication were done in Balzers BAF 400D high-vacuum freeze-fracture apparatus at $-120^{\circ}C$ under routine $5X10^{-7}$ Torr vacuum. The tissue was immediately replicated with platinum unidirectionally at $45^{\circ}$ angle and reinforced with carbon at $90^{\circ}$ angle unidirectionally or by using a rotary stage. The replication process was monitored by a quartz-crystal device. The replicas were immersed in 100% methanol overnight. The tissue was then digested from the replica by clorox (laundry bleach), placed into 5% EDTA, and washed repeatedly with distilled water. The replicas were picked up on 0.3% formvar-coated 75 mesh grids and examined in the JEOL 100B electron microscope. The results were as follows; 1. Both in thin sections and freeze-fracture replicas, three types of intercellular junctions were recognizable in the plasma membrane of odontoblast: gap junction, tight junction and desmosome-like junction. 2. The nuclear pores were evenly distributed over the nuclear envelope. The pore complex formed a ring about 70 nm in diameter. 3. Gap junctions were found between odontoblasts as well as odontoblasts and neighbouring pulp cells (fibroblast, subodontoblastic cell process, nerve-like fibre). Gap junctions, which were round, ellipsoid and pear-shaped and 600 nm in diameter, were observed in the odontoblast. 4. Numerous round and ellipsoid gap junctions could be frequently seen on the plasma membranes in cell body and apical part of the odontoblasts. On the P face, the junctions were recognized as a cluster of closely packed particles, measuring about 9 nm in diameter, and on the E face, the junctions were recognized as a shallow grooves.

  • PDF