• Title/Summary/Keyword: replacment

Search Result 9, Processing Time 0.019 seconds

Strength properties of matrix according replacment ratio by polysilicon sludge and active loess cement (활성황토 시멘트와 폴리실리콘 슬러지 치환율에 따른 경화체의 강도 특성)

  • Kang, Jeon-Wook;Lee, Won-Gyu;Kim, Dea-Yeon;Sin, Jin-Hyun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.265-266
    • /
    • 2018
  • In recent years, active loess cement has been used instead of cement in order to reduce the amount of cement and industrial byproducts that are the main cause of environmental pollution. We also used polysilicon sludge as a by-product to reduce the amount of cement used and to improve the environmental pollution due to the reduction of carbon dioxide. Polysilicon is a raw material used in the production of panels for solar power generation. When producing 1 ton of polysilicon, 2 tons of sludge is generated. It is an experiment to reduce sludge treatment and cement usage. This study analyzed basic characteristics of polysilicon sludge and active loess cement according to replacment ratio.

  • PDF

The Effects of Fly-ash Replacement on the Properties of Undispersed Underwater Concrete (플라이애시 치환율 변화에 따른 수중불분리 콘크리트의 특성에 관한 연구)

  • 원종필;최응규;이대주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.387-393
    • /
    • 1996
  • The purpose of this study is analyze the properties of undispersed concrete according to replacement of the ratio of fly-ash. The test results show that as the ratio of flyash replacement which increasing fluidity but the amounts of air content, suspended solid and pH values dicreased and setting time is delayed. The ten persent replacment of fly-ash has less water pollution and high compressive strength value than other ratio of fly-ash replacement.

  • PDF

Treatment of Temporomandibular Joint Disorder by Alloplastic Total Temporomandibular Joint Replacement

  • Roh, Young-Chea;Lee, Sung-Tak;Geum, Dong-Ho;Chung, In-Kyo;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.412-420
    • /
    • 2013
  • The literature on alloplastic total temporomandibular joint (TMJ) replacement is encouraging, with acceptable improvement of treatment outcomes in terms of both pain level and jaw function. This is a case report on patients who suffered from degenerative joint disease and ankylosis after mandibular condyle fracture or prior TMJ surgery and were treated by TMJ replacement with condyle prosthesis. We obtained good results from the procedures, including total TMJ replacement.

Quantitative Interchangeability Evaluation Method Considering Part Replacement Decision Algorithm of Small Equipment (소형장비의 부품 교체단위결정 알고리즘을 고려한 정량적인 교체성 평가방법)

  • Kim, Jong-Do;Son, Woo-Hyun;Park, Sang-Jin;Mok, Hak-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.537-544
    • /
    • 2019
  • In currently electronic systems, the speed of information integration has increased due to the development of electronic technology. However, due to the increase in the number of parts and groups, the product structure has become complicated. In this paper, a study was conducted to evaluate quantitatively the replacement of a small equipment. First, the level of the replacement was determined through the algorithm for the replacement level of parts. Next, we defined the ease of detail replacment, and the factors for each detail replacement. In order to calculate the weighting of the detail ease, we performed the analysis of the replacement process of subcomponents of communication exchanger and defined the evaluation criteria. Finally, the completion of the evaluation check sheet and the evaluation score table.

Evaulation of Adiabatic Temperature Rise for Concrete with Blast-Furnace Slag replacement (고로슬래그 미분말 치환율에 따른 콘크리트의 단열온도상승 평가)

  • Kim, Joo Hyung;Lee, Do Heun;Jung, Sang Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Recently, the interest is increasing about the eco-friendly concrete. Accordingly, the blast furnace slag(BFS), a by-product of industry is known for improving the durability through compaction in concrete and is expanding the use. The research about BFS in concrete be accomplished frequently. In this study, we should know the hydration characteristic of BFS concrete the through the adiabatic temperature rise test due to the replacement of a variety of BFS. In addition, we produced the regression analysis factors through the test result and analyzied the effect for the replacement of BFS. According to test results, the compressive strength showed a slight degradation or equal and the the adiabatic temperature rise figure and rising factors are went down for rising replacment of BFS. In the future, the study about the adiabatic temperature rise equation for the various replacement of BFS and binder is considered necessary.

  • PDF

Clinical Analysis of Bileaflet Mechanical Valve Replacement (Bileaflet Mechanical Valve의 임상적 고찰)

  • Kim, Mun-Hwan;Jin, Seong-Hun
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.677-685
    • /
    • 1993
  • Experience with bileaflet mechanical valve replacement at the Inha Hospital in 192 patients, operated on from June 1986 until April 1993. Two hundred fourty-one prostheses [51 Duromedics, 79 St.Jude Medical, and 111 CafboMedics]were implanted during the total 195 operations. Mitral valve replacment[MVR]was done in 113 cases, aortic valve replacement[AVR]in 34, tricuspid valve replacement[TVR]in 2, and double valve replacement[DVR]in 46 cases.Of the total patients, 63.0% were women and 37.0% were men. The mean age of the patients was 40.8 years, ranged from 14 to 67years. Overall early mortality was 9.2\ulcorner%[18 out of 195]; 9.7%[11 out of 113]for MVR, 14,7% [5 out of 34]for AVR, and 4.3%[2 out of 46]for DVR. All of the operative survors were followed over a period of one to 83 months with a mean of 37 months, for total 543 patient-years. So far, eleven patients[6.7% of the long-term survivors]were lost to follov-up after a mean postoperative follow-up of 22.8 months. There were nine late deaths; three deaths due to prostetic valve endocarditis, two due to persistent heart failure, one due to cerebral hemorrhage, one due to aortic dissection after Bentall oreration, and two sudden deaths. Actuarial survival rate at 6.9 years was 94.8%, There were seventeen valve-related complications; three prosthetic valve thromboses, three thrombembolisms, three instances of prosthetic valve endocarditis, two paravalvular leakages, and six hemorrhagic complications related to anticoagulation. The actuarial rate of freedom from all valve-related complications at 6.9years was 91.3%. There were significant decreases in the heart size postoperatively that can be demonstrated by comparison of cardio-thoracic ratios on simple chest X-ray and left ventricle dimensions on echocardiography. We conclude that this midterm follow-up shows good results in terms of hemodynamics and durability although further long-term evaluations are mandatory.

  • PDF

Use of the Native Aortic Valve as the Pulmonary Valve in the Ross Procedure (Ross 술식에서 자가대동맥판막을 이용한 우심실유출로 재건술)

  • 나찬영;이영탁;김수철;오삼세;김욱성;정철현;정도현;김웅한;이창하
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1222-1225
    • /
    • 1998
  • Aortic valve replacement in young patients has its problems. Biologic prosthetic valves degenerate and need replacement. Metalic prosthetic valves are more durable, however, anticoagulation which has its inherent problems is inevitable. The use of Ross procedure in young patients is gaining wider acceptance. The need of foreign pulmonary valve in right ventricular outflow tract(RVOT) will require reoperation due to RVOT obstruction, later. To overcome this problem, we reimplanted the native aortic valve in the pulmonary position in 21 year old female patient operated on utilizing the Ross procedure for aortic insufficiency. We experienced that the diseased aortic valve worked well in the pulmoanry position because of low pulmonary artery pressure and resistance.

  • PDF

transprosthetic Pressure Gradient after aortic Valve Replacement with Small Sized Prostheses (작은 기계 판막을 이용한 대도액 판막 치환술 후 판막 전후 압력차)

  • Hwang, Kyung-Hwan;Park, Kay-Hyun;Cha, Dae-Won;Jun, Tae-Gook;Park, Pyo-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.146-150
    • /
    • 2000
  • background: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. Material and method: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. result: The mean pressure gradient and body surface area in each group were 21.7$\pm$10.2 mmHg and 1.52$\pm$0.14m2 in ATS 19mm 11.4$\pm$6.5 mmHg and 1,57$\pm$0.20m2 in M-H 20mm 15.2$\pm$6.3 mmHg and 1.54$\pm$0.13m2 in ATS 21mm 9.3$\pm$2.5 mmHg and 1.63 $\pm$0.14m2 in M-H 22 mm and 12.9$\pm$5.3 mmHg and 1.69$\pm$0.13m2 in ATS 23mm. Conclusion: The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.

  • PDF

Preservation of Subvalvular Apparatus During Mitral Valve Replacement (판막하부 구조물을 보존하는 인공 승모판막 치환술)

  • 임창영;임정철
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1329-1336
    • /
    • 1996
  • From January, 1994 to January. 1996, mitral valve replacement was performed in 27 patients. Among these, 17 patients underwent mitral valve replacement(MVR) with preservation of the annulo-papillary continuity(PAPCMVR) (-Group I), and 10 patients underwent conventional methods of excision of all the chordae(Group II). The operative technique for PAPCM VR consists of the division of the anterior leaflet into anterior and posterior segments, shifting and reattachment of the divided segments to the mitral ring of the respective commissural areas. This retrospective study has been designed to evalute the postoperative left ventricular function in the two groups. In the group 1, LVEF(Left Vnetricular Ejection Fraction : %) was 52 $\pm$ 3 preoperatively And 50$\pm$3 postoperatively, LVESI Vent icular End Systolic Volume Index/mL/m2) wIns 59 :6 and 51 $\pm$ 7, LVEDI Ventricular End Diastolic Volume Index/mL/m2) was 124$\pm$ 11 and 91 :8. In the group II, LVEF was 56$\pm$1 and 47:), LVESVI 62$\pm$12 and 61$\pm$15, LVEDVI 133$\pm$27 and 104$\pm$17. : the variation of the LVEF in these two group was statistically different(p(0.05). A comparison of left ventricular function data between Group I(n: 17) and Group II(n: 10) revealed better results in echocardiographic LVEF(p<0.05), LVEDVI(p<0.01) in the former group. The mean functional class(UYHA) was 2.6 preoperative and improved to 1.0 postoperatively In group 1, and 2.8 and to 1.0 in group II. We conclude that maintenance of continuity between the mitral annulus and papillary muscles is expected to have a beneficial effect on postoperative left ventricular performance.

  • PDF