• Title/Summary/Keyword: replacement rate

Search Result 1,131, Processing Time 0.03 seconds

A Random Replacement Model with Minimal Repair

  • Lee, Ji-Yeon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.8 no.1
    • /
    • pp.85-89
    • /
    • 1997
  • In this paper, we consider a random replacement model with minimal repair, which is a generalization of the random replacement model introduced Lee and Lee(1994). It is assumed that a system is minimally repaired when it fails and replaced only when the accumulated operating time of the system exceeds a threshold time by a supervisor who arrives at the system for inspection according to Poisson process. Assigning the corresponding cost to the system, we obtain the expected long-run average cost per unit time and find the optimum values of the threshold time and the supervisor's inspection rate which minimize the average cost.

  • PDF

Optimal replacement policy after extended warranty for a system with minimal repair warranty (최소수리 보증을 갖는 시스템에 대한 연장된 보증 이후의 최적의 교체정책)

  • Jung, Ki Mun
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.77-86
    • /
    • 2013
  • Recently, an extended warranty of a system following the expiration of the basic warranty is becoming increasingly popular to the user. In this respect, we suggest a replacement model following the expiration of extended warranty with minimal repair warranty from the user's point of view in this paper. Under extended warranty, the failed system is minimally repaired by the manufacturer at no cost to the user during the original extended warranty period. As a criterion of the optimality, we utilize the expected cost rate per unit time during the life cycle from the user's perspective and suggest the optimal replacement period after extended warranty. Finally, a few numerical examples are given for illustrative purpose.

Evaluation on the Properties of Mortar using Waste Shells for Partical Replacement of Fine Aggregate (패각류를 잔골재 대체재로 사용한 모르터의 기초물성 평가)

  • Kim, Ji-Hyun;Cho, Kwang-Hyun;Lee, Jae-Yong;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.148-149
    • /
    • 2013
  • Recently, the construction industry in South Korea, has experienced many difficulties in lack of supply with construction materials. Since waste shells can be possibly used as replacement materials of fine aggregate, the successful application can resolve, to some extent at least, the economic problems and environmental problems. In this research, the basic physical properties of the mortar which was used as fine aggregate substitute (clam, cockle, manila clam, oyster) were evaluated. According to the experimental results, the absorption rate and compressive strength of samples with various shells were equivalent to that of plain mortar. The mortar which replaced 25% of oyster shell with sand showed approximately 30% lower compressive strength and twice as much absorption as plain mortar. It was found that waste shells can be used as replacement materials of fine aggregate, but the oyster shell requires further experimental works in order for its successful application.

  • PDF

A Study on Evaluation of Optimal Replacement Period by Reliability Prediction for the Door Control Relay of EMU (전동차 출입문제어 계전기의 신뢰도예측을 통한 적정 교체주기 연구)

  • Han, Jaehyun;Kim, JongWoon;Koo, JeongSeo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.34-40
    • /
    • 2014
  • In this paper, we want to know the optimal replacement cycle(time) for this study was performed. The optimal preventive replacement age can be fond by finding the value of time that minimizes the cost function(model of Barlow and Jardine). In addition, The reliability of the relay according to the service environment were studied. The use of the exchange relay period is longer, and maintenance cost rate(per hour) may increase, and also the reliability may cause a decline. In addition, considering the preventive maintenance and purchase order, a representative relay(RAX-L440-A type) life was calculated.

On Optimal Replacement Policies for a Deteriorating System (기능저하 시스템에서의 최적 교체 정책)

  • Ji Hwan Chan
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.4
    • /
    • pp.94-105
    • /
    • 2002
  • In this paper, replacement problems for a deteriorating system are considered. In the system under consideration, the successive lifetimes after repair become shorter and shorter, while the consecutive repair times become longer and longer. More specifically, the lifetimes of the system form a nonhomogeneous Poisson process, whereas the consecutive repair times constitute a stochastically increasing geometric process. Optimal replacement policies for the long-run average cost rate and the steady state availability are considered. Also taking the cost and the availability into consideration at the same time, the properties of optimal policies under the Cost Priority Policy and the Availability Priority Policy are obtained.

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF

Clinical Experience of Abdominal Aortic Aneurysm (복부 대동맥류의 임상적 경험)

  • Gu, Bon-Il;O, Sang-Jun
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.263-267
    • /
    • 1995
  • A total and consecutive 87 patients underwent aortic valve replacement[AVR with the St. Jude Medical prosthesis between 1984 and 1993. Age ranged from 14 to 66 years[mean:38.6$\pm$ 14.0 years .Twenty-one patients [24.1% had undergone previous valve replacement. There were 8 early deaths with an operative mortality rate of 9.2% [7.6% for primary AVR and 14.3 % for re-replacement AVR . Seventy-nine early survivors were,followed for a total of 309.1 patient-years[mean:3.9$\pm$ 2.5 years . A late mortality rate was 5.1% [4 patients or a linearized incidence of 1.294 %/patient-year. All were anticoagulated with coumadin to maintain the international normal ized ratio[INR between 1.5 and 2.5. One patient experienced thromboembolism[0.324%/patient-year , and none did bleeding. Endocarditis occurred in one[0.324%/patient-year . Paravalvular leak was the most frequent complication and was experienced by 8 patients[2.588%/patient-year , and 5 of them required re-replacement AVR[1.618 %/patient year of reoperation rate . There was no structural failure of the prosthesis. Actuarial survival including operative death was 83.9%$\pm$ 4.6% at 10 years.The actuarial estimates of freedom from thromboembolism and of freedom from late death and all complications were 95.1% $\pm$ 4.8 % and 81.4% $\pm$ 6.1%, respectively, at 10 years. These clinical results suggest that less intensive anticoagulation may be allowed for patients of AVR with the St. Jude Medical valve with low incidences of both thromboembolic and bleeding complications.

  • PDF

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

The Clinical Results of Heart Valve Replacements (심장 판막 치환술의 임상 성적)

  • Park Sung Min;Son Hosung;Shin Jaesung;Sohn Young-sang;Sun Kyung;Choi Young Ho;Kim Kwan Taik;Lee In Sung;Kim Hackje;Kim Hyung Mook
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.204-213
    • /
    • 2005
  • In spite of the improvement in the quality of artificial heart valves and surgical techniques, the incidence of the complications following valve replacement is still high. We reviewed the clinical results of the valve replacements peformed in Korean University Anam Hospital during the last 26 years. Material and Method: The data of 571 patients who received valve replacement between December 1976 and December 2003 were reviewed. Result: There were 304 cases of MVR which was the most common procedure performed. There were 122 cases of AVR, and 111 cases of AVR with MVR. Among the 47 patients who received redo operation 38 cases were redo cases including 31 cases of MVR. $32.5\%$ of the patients who had tissue valve replacement had second valve replacement with 10.2 $\pm$ 3.9 years interval. $24.3\%$ (139/571) of the patients developed valve related complications and cerebral infarction was the highest in frequency. Atrial fibrillation was related with increased complication rates and the mechanical valve replaced group had higher hemorrhagic complication rate than tissue valve replaced group. The operative mortality was $3.68\%$ and the most common cause of the failure was low output syndrome. The operative mortality was higher in the patient group who had valve replacement before the year 1990. The patient group who had mechanical valve replacement had higher operative mortality rate th;3n the tissue valve group. The 5-year survival rate was $92.2\%$ and 10 year survival rate was $85.7\%$. Conclusion: The operative mortality of valve replacement has been improved. The mechnical valve replaced patients had higher hemorrhagic complication rate than the tissue valve replaced patients and more tissue valve replaced patients received redo valve replacement.

Clinical Analysis of Bileaflet Mechanical Valve Replacement (Bileaflet Mechanical Valve의 임상적 고찰)

  • Kim, Mun-Hwan;Jin, Seong-Hun
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.677-685
    • /
    • 1993
  • Experience with bileaflet mechanical valve replacement at the Inha Hospital in 192 patients, operated on from June 1986 until April 1993. Two hundred fourty-one prostheses [51 Duromedics, 79 St.Jude Medical, and 111 CafboMedics]were implanted during the total 195 operations. Mitral valve replacment[MVR]was done in 113 cases, aortic valve replacement[AVR]in 34, tricuspid valve replacement[TVR]in 2, and double valve replacement[DVR]in 46 cases.Of the total patients, 63.0% were women and 37.0% were men. The mean age of the patients was 40.8 years, ranged from 14 to 67years. Overall early mortality was 9.2\ulcorner%[18 out of 195]; 9.7%[11 out of 113]for MVR, 14,7% [5 out of 34]for AVR, and 4.3%[2 out of 46]for DVR. All of the operative survors were followed over a period of one to 83 months with a mean of 37 months, for total 543 patient-years. So far, eleven patients[6.7% of the long-term survivors]were lost to follov-up after a mean postoperative follow-up of 22.8 months. There were nine late deaths; three deaths due to prostetic valve endocarditis, two due to persistent heart failure, one due to cerebral hemorrhage, one due to aortic dissection after Bentall oreration, and two sudden deaths. Actuarial survival rate at 6.9 years was 94.8%, There were seventeen valve-related complications; three prosthetic valve thromboses, three thrombembolisms, three instances of prosthetic valve endocarditis, two paravalvular leakages, and six hemorrhagic complications related to anticoagulation. The actuarial rate of freedom from all valve-related complications at 6.9years was 91.3%. There were significant decreases in the heart size postoperatively that can be demonstrated by comparison of cardio-thoracic ratios on simple chest X-ray and left ventricle dimensions on echocardiography. We conclude that this midterm follow-up shows good results in terms of hemodynamics and durability although further long-term evaluations are mandatory.

  • PDF