• 제목/요약/키워드: repetitive over-current pulse

검색결과 2건 처리시간 0.016초

초전도한류기에 적용하는 YBCO 박막형 선재의 반복적 과전류 특성 (Repetitive Over-current Characteristics of YBCO Coated Conductor for Applying to SFCL)

  • 안민철;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.26-31
    • /
    • 2007
  • In recent years. YBCO coated conductor (CC) called as second generation HTS (high temperature superconducting) wire has been developed as a suitable material for resistive superconducting fault current limiter (SFCL). For designing the SFCL. the required length of superconducting wire is inverse proportional to the maximum temperature reached when a fault occurs. Since the required length strongly affects a manufacturing cost, it is the most important parameter to determine the maximum temperature reached. It is necessary to observe the repetitive over-current characteristics of HTS wire. This paper attempts to measure the variation of critical current of YBCO CC after repetitive over-current pulse. No degradation of the critical current of CC sample was observed by applying 100 times over-current pulse which makes temperature above 400 K after 100ms. This study can be useful in designing optimally resistive SFCL employing YBCO CC. The maximum permissible temperature can be set to 400K. so wire length could be reduced by 30% compared in case of 300K-criterion.

Study of Pulse Generation Technique for Serial dual Electrode Detection of Amino Acids and Proteins in Flow Injection Analysis

  • Fung, Ying-Sing;Mo, Song-Ying
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.575-582
    • /
    • 1995
  • A new analytical procedure using a serial dual electrode detector was developed for the analysis of amino acids and proteins. Bromine was generated at the upstream electrode and detected by the downstream electrode. The presence of amino acids and proteins was shown to lower the downstream current but with no apparent effect on the upstream current. This indirect mode of detection can be applied to the determination of amino acids and proteins which are electrochemically inactive or too large to be accessible to the electrode surface for electron exchange. The method is shown capable to determine various amino acids (cystine, tyrosine, lysine, tryptophan, glycine, methionine and arginine) and proteins (cytochrome c, hemoglobin, HAS, a-Amylase, Conalbumin I, Catalase and Myglobin) with linear working range for amino acids between $10^{-6}$ to $10^{-3}M$ and total proteins between $10^{-7}$ to $10^{-3}M$. The method has been applied for the analysis of amino acids and total protein in food using Flow Injection Analysis with results obtained comparable to those using the traditional analytical procedure. Use of pulse generation technique was shown to produce a more stable flow injection analysis peaks for repetitive determination than the use of conventional constant current method which showed increase of the background current after determination over 200 minutes. The pulse method was found to give stable baseline even after 400 minutes. Thus, the method is shown able to provide a suitable analytical procedure for automatic analysis of amino acids and proteins in food by flow injection analysis.

  • PDF