• Title/Summary/Keyword: repeated measurements data

Search Result 147, Processing Time 0.022 seconds

Repeated Records Animal Model to Estimate Genetic Parameters of Ultrasound Measurement Traits in Hanwoo Cows (반복모형을 이용한 한우 초음파 측정형질의 유전모수추정)

  • Park, Cheol-Hyeon;Koo, Yang-Mo;Kim, Byung-Woo;Sun, Du-Won;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Lee, Jae-Youn;Jeoung, Yeoung-Ho;Lee, Jung-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.71-75
    • /
    • 2012
  • The present study data were obtained from 36,894 cows in Korea Animal Improvement Association from 2001 to 2009 which was subjected for ultrasound measurements (eye muscle area, back-fat thickness, marbling score) and descent. Repeated record models were carried out using 7,913 of 36,894 of total animal traits. The ultrasound measured traits and performance test data were used to study the chest girth, body condition score, eye muscle area, back-fat thickness and marbling score with genetic correlation and parameters for the ultrasound measured traits using REMLF90 program. Genetic correlation of eye muscle area with back-fat thickness, marbling score and back-fat thickness with marbling score were noticed in repeated records animal model as 0.69, 0.54, and 0.59, whereas in multiple trait animal model method were 0.07, 0.66, and 0.39, respectively. Repeated records of animal models were used as positive correlation of traits. Multiple trait animal models were used as negative correlation of eye muscle area with marbling score. The analysis on repeat records of animal models using ultrasound measurements about Korean cattle showed positive effects for each traits. In comparison differences between the repeat records of animal models and multiple trait animal models was found with higher traits of her, the heritability and repeatability was found higher in repeat records animal models. In light of these assessments, carcass traits by ultrasound measurements are expected to help and improve an accurate analysis of each trait and if the research analysis using repeat records of animal models continue when we estimate genetic ability of these traits.

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Bayesian Conway-Maxwell-Poisson (CMP) regression for longitudinal count data

  • Morshed Alam ;Yeongjin Gwon ;Jane Meza
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.3
    • /
    • pp.291-309
    • /
    • 2023
  • Longitudinal count data has been widely collected in biomedical research, public health, and clinical trials. These repeated measurements over time on the same subjects need to account for an appropriate dependency. The Poisson regression model is the first choice to model the expected count of interest, however, this may not be an appropriate when data exhibit over-dispersion or under-dispersion. Recently, Conway-Maxwell-Poisson (CMP) distribution is popularly used as the distribution offers a flexibility to capture a wide range of dispersion in the data. In this article, we propose a Bayesian CMP regression model to accommodate over and under-dispersion in modeling longitudinal count data. Specifically, we develop a regression model with random intercept and slope to capture subject heterogeneity and estimate covariate effects to be different across subjects. We implement a Bayesian computation via Hamiltonian MCMC (HMCMC) algorithm for posterior sampling. We then compute Bayesian model assessment measures for model comparison. Simulation studies are conducted to assess the accuracy and effectiveness of our methodology. The usefulness of the proposed methodology is demonstrated by a well-known example of epilepsy data.

Three-dimensional morphological evaluation of the hard palate in Korean adults with mild-to-moderate obstructive sleep apnea

  • Yu, Chen;Ahn, Hyo-Won;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.48 no.3
    • /
    • pp.133-142
    • /
    • 2018
  • Objective: The purpose of this study was to evaluate differences in three-dimensional (3D) morphology of the hard palate between Korean adults with and without mild-to-moderate obstructive sleep apnea (OSA) using cone-beam computed tomographic (CBCT) data. Methods: The protocol for the two-dimensional (2D) and 3D mathematical modeling was established by analyzing CBCT images of 30 adults with OSA and 30 matched controls without OSA, using MIMICS software. The linear and angular measurements were also determined using this software. The measurements were repeated for 30 palates, by the same operator, to assess reliability. Results: The palates of OSA patients were higher in the posterior part and narrower in the anterior-superior part than those of the control group (p < 0.05). The nasal cavities of patients with OSA were narrower (p < 0.05) than those of controls. The increasing angle of the first molar palatal root is a compensation of the upper dental arch to improve occlusion. However, for most palatal measurements, there were no significant differences between the OSA and control groups (p > 0.05). The results of 2D and 3D mathematical models were consistent for linear and angular measurements, indicating that 2D and 3D mathematical modeling of the palate is a reliable methodology. Conclusions: OSA is a multifactorial disease; the palates of adults with mild-to-moderate OSA do not have specific morphological features distinct from those of healthy controls.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Effects of Premixed Flame on Turbulence Properties in a Pilot Flame Stabilized Jet Burner (파일럿 안정화 제트버너의 예혼합 화염이 미연가스 영역 난류특성에 미치는 영향)

  • Lee, Dae Hoon;Kwon, Sejin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1172-1177
    • /
    • 1999
  • Comparisons of measured turbulence properties in the unburned gas region of turbulent premixed flame stabilized by pilot flame, in cases of combusting and non-combusting flow conditions, are presented. Methane-air premixed jet at fuel equivalence ratio of 0.6 and 1.0 and Reynolds number of 7,000 was diagnosed using two-color laser velocimeter to obtain turbulence statistics. Same set of measurements was repeated at 21 locations within the unburned gas region of both combusting and non-combusting conditions. Velocity data were analyzed to evaluate the spatial distribution of turbulence properties including Reynolds stress, probability densities, joint probability densities and auto correlations. Contrary to assumptions of current theoretical models, significant influence of flame was observed in every property that was studied in the present investigation. The effective viscosity increased ten-fold when flame was on from cold flow values. The effect of mixing on joint probability as well as in turbulence intensity was suppressed by the flame. The measurements suggest that common assumptions of premixed flame model may result in sizable error in prediction of flame length and temperature distribution in near-field.

X-RAY FLUORESCENCE IN RESEARCH ON THE CULTURAL HERITAGE

  • Cechak, Tomas;Kopecka, Ivana;Musilek, Ladislav
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.321-326
    • /
    • 2001
  • Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging to the Czech cultural heritage. The results are promising. Thus it is expected that our laboratory will expand its work into more fields of the fine and applied arts.

  • PDF

Basic Measurements and Dosage Compensation for Total Body Irradiation (전신조사를 위한 선량 측정과 보상)

  • 김진기;권형철;김정수;김부길;추성실
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.25-34
    • /
    • 1992
  • For the TBI with medical linear accelerator(6.10MV), we measured basic data for dosage calculation and designed compensation filters to improve dose uniformity. At the distance of 3.4cm from the source, using the specially designed compensation filters reduced with in ${\pm}$5% for mid-depth dose in the phantom seated with flexion of the legs in the field sige up to 120${\times}$120cm$^2$ for the whole body. In repeated measurements for the dose distribution with humanoid phantom contained paraflin compound, measurement error using the TLD chips were less than ${\pm}$5%.

  • PDF

Study on Effect of Warmth Therapy Nursing Intervention Program after Laparoscopic Cholecystectomy (복강경담낭절제술 후 가온요법 간호중재 프로그램 적용 효과)

  • Lee, Jung-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.350-356
    • /
    • 2020
  • Purpose: This study is a non-equilibrium control-like experimental study that attempts to develop a nursing intervention plan and to present basic data by grasping the effect of the heating therapy nursing intervention program on patients entering the recovery room after surgery. Method: The subjects of the study were 31 in an experimental group and 31 in a control group who applied one heating therapy program located in D city. The warming therapy was conducted in a recovery room in the range of 38 to 43℃ through a heater. The general characteristics of the subjects were determined by real number and percentage, and a homogeneity test between the experimental group and the control group was determined by 𝑥2-test and independent t-test. The difference in body temperature, pain, and tremor over time between the two groups was determined by repeated measure ANOVA. Results: First, the results of repeated measurements immediately after surgery showed significant differences in body temperature, pain, and tremor between the two groups. Second, temperature comfort showed a significant difference. Conclusion: The results confirmed that there was a positive effect on the patient in the intervention of warming therapy after surgery.

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.