• 제목/요약/키워드: repeated dose

검색결과 494건 처리시간 0.028초

Assessment of Chronic Toxicity of an Ayurvedic Herbo-Metallic Formulation Rasaraj Rasa in Wistar Rats

  • Chaitali S. Waghmare;Shivcharan R. Bidve;Ramacharya V. Gudi;Megha L. Nalawade;Mukesh B. Chawda
    • 대한약침학회지
    • /
    • 제25권4호
    • /
    • pp.354-363
    • /
    • 2022
  • Objectives: This study aimed to assess the adverse effects of Rasaraj Rasa tablets after repeated oral administration for 180 days in Wistar rats. Methods: Wistar rats were divided into five groups, of which three were treated with 54, 162, and 270 mg/kg body weight of Rasaraj Rasa, respectively, which correspond to one, three, and five times the proposed human therapeutic dose, for 180 days consecutively. The fifth group (satellite) also received 270 mg/kg body weight of Rasaraj Rasa for 180 days. Body weight and food intake were measured weekly. At the end of the study, all rats were sacrificed, and their blood, serum, and organs were collected and examined using hematology, serum biochemistry, gross pathology, and histopathology tests. In contrast, the satellite group was kept for 4 weeks after treatment. Results: No significant treatment-related toxicological findings were observed in the clinical features, body weight, laboratory findings, and pathological findings of the high-dose treated groups, when compared to those of the control group. Conclusion: The no-observed-adverse-effect-level for Rasaraj Rasa in Wistar rats is set at 270 mg/kg body weight.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Whole Spine Scanography의 검사방향에 따른 환자 선량 평가 (Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction)

  • 김정수;서덕남;권순무;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography(WSS)는 전신에 X선을 조사하는 검사로 치료기간 동안 빈번한 X선 조사가 이루어지는 검사이다. 일반촬영 분야에서는 많은 X선이 전신에 조사되는 검사이다. 따라서 논문에서는 Auto image pasta기법의 디지털 WSS 검사에서 환자의 검사방향에 따른 유효선량과 장기선량을 전산모사를 통하여 평가하였고, 영상에서 척추의 확대도와 각도의 변화를 평가하였다. 전후면 자세에서의 평균 유효선량은 0.069 mSv였고, 후전면 자세에서 평균 유효선량은 0.0361 mSv로 약 2배의 차이를 보였다. 전후면 자세에서 남성의 평균 유효선량은 0.089 mSv, 여성에 대한 평균 유효선량은 0.431 mSv로 나타났고, 후전면 자세에서 남성의 평균 유효선량은 0.050 mSv, 여성에서는 0.026 mSv로 나타났다. 확대율에서는 후전면 자세에서 전후면 자세에 비해 5%정도 확대 되었으나 각도에는 큰 변화를 보이지 않았다. 따라서 임상 환경에서 동일한 검사조건에서 환자의 자세를 변화시키는 것만으로도 환자의 피폭선량을 감소시킬 수 있음을 확인하였다. 특히 WSS와 같이 치료기간 동안 반복되는 검사에서 환자의 피폭선량 최적화를 위하여 검사 프로토콜의 재정립이 필요함을 확인하였다.

2-Bromopropane의 수컷 랫트를 이용한 고환 독성시험 (Testicular Toxicity of 2-Bromopropane in Male Sprague-Dawley Rats)

  • Cha, Sang-Eun;Park, Sang-Rae;Kim, Kgu-Hwan;Choi, Jeung-Suk;Kim, Sung-Kuk;Jeon, Tae-Won
    • Environmental Analysis Health and Toxicology
    • /
    • 제15권4호
    • /
    • pp.123-130
    • /
    • 2000
  • 택트 스위치 제조공정 침지액의 주성분인 2-bromopropane독성에 대한 연구로 최단기의 폭로로 농도를 달리하여 3주간 반복 투여 시험을 시행하여, 흰쥐의 혈액 및 세정관의 변화를 관찰하기 위해 투여기간 동안의 체중의 변화, 고환, 간, 신장 등의 장기무게, 혈액화학과 혈액학적 분석 및 고환의 병리조직의 변화 등을 관찰하여 2-bromopropane의 급성투여 조건에서의 중독현상을 비교.분석하였다. 농도를 달리하여 투여에 따른 체중변동은 통계적으로 유의한(P<0.05)체중의 감소를 나타내었다. 1.000 mg/kg 투여군에서 백혈구수, 적혈구수, 혈구용적과 혈색소 농도에서 유의한 변화(p<0.05)를 보였다. 조직병리학적 소견으로 정 소에서는 세정관의 정조세포와 정모세포의 괴사를 볼 수 있었고, 기저막의 비후, 세정관의 Sertoli세포는 광범위하게 세포질성 공포현상을 보여주고 있다. 또한 간질조직에서는 Leydig 세포의 증식을 볼 수 있었다. 2-bromopropane의 손상부위는 조혈과 생식계가 표적으로 생각되며, 고농도 투여가 저농도 투여에 비해 독성이 심하며 독성물질의 양-반응 관계를 보여주고 있다.

  • PDF

폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교 (Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT)

  • 이원정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.329-336
    • /
    • 2016
  • 본 연구에서는 폐기종에 대해 고해상도 CT와 비교한 저선량 CT 의 유용성에 대해 평가하였다. 고해상도 CT와 저선량 CT 노출조건에서 선량과 영상 잡음을 3회 반복 측정하였다. 비슷한 노출조건에서 획득한 146명의 고해상도 CT와 저선량 CT 영상에 대해 2명의 흉부영상의학과전문의 합의 판독결과에서 폐기종 소견 만을 본 연구에 사용하였다. SPSS ver. 19.0 프로그램 사용하여 고해상도 CT와 저선량 CT 간에 폐기종에 대한 진단 차이는 McNemar's tests, 일치도는 unweighted kappa tests, 선량과 잡음 차이는 Mann-Whitney U-test 로 분석하였다. 선량은 고해상도 CT가 저선량 CT 보다 높았지만(1.95 mGy vs. 0.35 mGy, p=0.008), 잡음은 낮았다(40.1 HU vs. 99.6 HU, p=0.021). 폐기종 진단에 대해서는 두 영상 간에 높은 일치도를 보였다(k-value=0.88). 폐기종 점수는 두 영상 간에 통계적인 유의한 차이를 보이지 않았고, 높은 상관성을 보였다(r=0.599, p < 0.001). 선량과 잡음을 고려했을 때, 저선량 CT는 폐기종 진단에 표준 진단 방법 인 고해상도 CT를 대신하여 사용할 수 있을 것으로 사료된다.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

수용성 님추출물이 랫드의 간 독성에 미치는 영향 (Effects of Aqueous Azadirachta indica Extract on Hepatotoxicity in Rats)

  • 박경훈;윤현주;한범석;이제봉;정미혜;조남준;엄애선;백민경
    • 한국환경농학회지
    • /
    • 제33권4호
    • /
    • pp.395-402
    • /
    • 2014
  • 님추출물은 유효성분(active ingredient)으로 azadirachtin을 함유하여 전세계적으로 충해방제용 유기농업자재로 널리 사용되고 있다. 그러나, 님추출물은 님 원료부위 및 추출용매에 따라 종류가 매우 다양하고 안전성에 크게 차이가 난다고 보고되고 있다. 본 연구에서는 우리나라에서 유기농업자재 제품의 원제로 사용되는 수용성 님추출물이 주요 독성기관인간에 미치는 영향에 대해서 살펴보고자 SD 랫드를 이용하여 4주 반복경구독성시험을 수행하였다. 시험결과, 님추출물 시험물질의 투여 농도가 증가함에 따라 간의 상대중량이 증가하였다(p <0.05). 혈액 생화학분석 결과, 수컷에서 대조군에 비해 시험물질 처리시 혈중 LDH는 감소하였으나 GOT와 GPT가 증가하였으며(p <0.05), 특히 GPT가 시험물질에 농도 의존적으로 증가함에 따라 수컷에서 간 손상의 가능성을 나타내었다. 또한, 고농도로 님추출물 시료를 처리한 경우 수컷의 혈중 GGT가 급격히 증가하였으며 혈중 GLU도 유의적으로 증가하였으나(p <0.05), 뇨 중 GLU는 님추출물의 처리농도증가에 따른 변화가 나타나지 않았다. 간의 조직병리학적 변화를 살펴본 결과 님추출물 시료 처리에 따른 간의 병변도 확인되지 않았다. 따라서 본 시험에 사용된 수용성 님추출물 시료는 혈액 생화학적 분석 결과 수컷에서 간손상의 가능성은 있었으나 조직병리학적 변화는 관찰되지 않았다. 따라서, 수용성 님추출물 2.0 g/Kg 을 4주간 랫드에 경구투여한 결과 간에 독성을 미치지 않고 안전한 것으로 판단된다.

생강나무(Lindera obtusiloba Blume) 잎 70% 에탄올 추출물의 단회와 14일 반복투여 독성시험의 안전성 평가 (Single and 14-Day Repeated Oral Toxicity Studies of 70% Ethanol Extract of Lindera Obtusiloba Blume Leaves)

  • 홍충의;서문영;구윤창;남미현;이현아;김지훈;왕증;양성용;이성희;노수환;이광원
    • 한국식품영양과학회지
    • /
    • 제38권10호
    • /
    • pp.1324-1330
    • /
    • 2009
  • 생강나무는 한국, 일본, 중국 등지에서 자생하며 열, 복통, 타박상, 출혈 등에 민간요법으로 사용되어온 식물이다. 이 논문의 목적은 오래전부터 민간요법으로 사용되어온 생강나무 잎의 안전성을 평가하고자 생강나무 잎 70% 에탄올 추출물을 암수 각 군당 5마리씩 5000(단회투여 독성시험), 0, 500, 1000, 2000(14일 반복투여 독성시험) mg/kg의 용량으로 단회경구투여와 14일 반복경구투여를 실시하여 15일간의 사망률, 일반증상, 체중변화, 조직병리, 혈액학적 및 혈액 생화학적 검사를 실시하였다. 시험기간 중 사망동물은 암수 모든 시험군에서 관찰되지 않았으며, 일반증상, 체중변화, 조직병리, 혈액학적 및 혈액생화학적 검사에서 투여와 관련된 변화는 관찰되지 않았다. 이상의 결과로 보아 생강나무의 단회투여 독성은 5000 mg/kg 용량을 상회하며, 14일 반복투여의 최고용량인 2000 mg/kg 용량에서도 아무런 독성이 나타나지 않는 것으로 보아 최대무독성량은 이 농도를 상회하는 것으로 판단된다. 이로써 생강나무는 안전한 소재로서 식재료 또는 건강기능식품의 원료로서도 사용이 가능하다고 볼 수 있다.

Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - I. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말(7%)의 랫드를 이용한 90일 반복경구투여 독성시험 평가 연구 - (Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - I. Repeated 90-day Oral Administration Toxicity Test using Rats Administered Hydrolyzed Whey Protein Powder containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method -)

  • 노혜지;조향현;김희경
    • Journal of Dairy Science and Biotechnology
    • /
    • 제34권2호
    • /
    • pp.99-116
    • /
    • 2016
  • 본 시험은 sialic acid가 7%를 함유하도록 제조한 유청가수분해단백분말제제(whey protein of hydrolysis)의 기능성 식품원료로 개발을 위한 동물안전성을 평가함에 연구목표를 두었다. GMP를 원료로 제조한 시험물질은 sialic acid 7%(v/v)와 원료인 GMP 가수분해 단백질이 93%로 구성되어 있었다(시험명: 7%-GNANA). 시험물질의 독성 유무는 한국식품의약안전청(KFDA, 2014)과 OECD(2008)의 의약품 등의 독성시험 기준에 따라 실시하였다. 평가방법으로서, 시험물질의 투여용량을 0, 1,250, 2,500 및 5,000 mg/kg/day로 하여 SPF Sprague-Dawley 계열 암수 랫드에 90일 동안 반복경구투여하였을 때 나타나는 독성 여부를 평가하였다. 평가항목으로서는 사망률, 일반증상관찰, 체중 변화, 사료 섭취량 측정, 안검사, 요검사, 혈액학적 및 혈액생화학적 검사, 부검 시 장기의 중량측정, 부검 시 육안적 검사 및 조직병리학적 검사 등을 평가하였다. 90일 반복경구투여 실험결과로서, 시험물질투여 및 관찰기간 동안 사망동물은 발생하지 않았다. 또한 일반증상, 체중 변화, 사료섭취량, 안과학적 검사, 요검사 그리고 혈액학적 및 혈액이화학적 이상 및 혈액응고검사에서 대조군 대비 특이한 변화는 관찰되지 않았다(p<0.05). 부검 및 병리조직학적 평가 결과, 암수 모두에서 시험물질-유래 중요한 변화 없이 시험물질-유래 경미한 변화(non-adverse effect)만인 5,000 mg/kg/day에서 확인되었다. Weight-based classification(독성 강도에 따른 분류)을 적용한 최종 독성평가 결과, 수컷의 경우 NOEL(No Observed Effect Level)은 5,000 mg/kg/day 그리고 암컷의 경우는 NOAEL(No Observed Adverse Effect Level)은 5,000 mg/kg/day로 최종 확인되었다. 따라서, 암수 모두에서 시험물질의 NOAEL은 투여최대용량인 5,000 mg/kg/day로 확인되었다. 결론적으로, GMP를 원료로 하여 제조한 7%-GNANA(유청가수분해단백분말)는 투여가능 최대용량에서도 독성이 없는 안전한 천연물이라는 것을 확인하였고, 의약품이나 기능성 식품으로서의 개발 가능성을 확인하였다.

kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰 (Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography)

  • 나종억;이도근;김진수;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.67-74
    • /
    • 2009
  • 목 적: 전립선암 환자를 대상으로 kV 콘빔CT를 이용한 영상유도방사선치료 시 촬영조건에 따른 인체의 각 장기들에 미치는 흡수선량(absorbed dose)과 유효선량(effective dose)을 비교 평가해 보고자 한다. 대상 및 방법: 환자를 대상으로 직접 실험할 수 없으므로 인체의 구성과 조직이 흡사한 인체 모형 팬텀(Anderson rando Phantom, Alderson Research Laboratories Inc., USA)과 전산화 단층 모의치료기(Lightspeed RT CT, GE, USA)를 이용하여 국제 방사선 방호 위원회(International Commission on Radiological Protection, ICRP)에서 권고된 신체 내 중요 장기들을 묘사하였다. 팬텀 내부의 묘사된 주요 장기에 선량 측정을 위하여 열형광선량계(TLD 100 Lif rods, Harshaw Chemical Co., USA)를 1~8개 삽입한 후 팬텀의 중심을 전립선에 위치시키고, On board imager (OBI) System이 부착된 의료용 선형 가속기(Clinac iX, Varian, USA)를 이용하여 두 가지 촬영모드인 표준모드(Standard-mode, A-mode)와 저선량모드(Low-dose mode, B-mode)에서 kV 콘빔 CT 촬영을 각 3회씩 반복해서 측정하였다. 결 과: 인체 모형 팬텀을 이용하여 전립선암 환자를 대상으로 한 kV 콘빔 CT 촬영을 시행한 결과 전립선, 방광, 직장에 대한 흡수선량은 A-mode인 경우 각각 5.5 cGy/1회, 6.5 cGy/1회, 5.7 cGy/1회, B-mode인 경우 1.1 cGy/1회, 1.3 cGy/1회, 1.2 cGy/1회 결과를 보였다. 각 장기에 대한 조직가중치를 고려한 유효선량은 A-mode와 B-mode에서 19.1 mSv, 4.4 mSv의 결과로 나타났다. kV 콘빔CT 촬영 시 인체에 미치는 유효선량을 측정한 결과, 전립선암 영상유도방사선치료 시 A-mode 콘빔CT는 B-mode 콘빔CT보다 환자가 받는 선량이 약 4배 이상 증가하는 것을 알 수 있었다. 결 론: 그러므로 전립선암 영상유도방사선치료 시 환자가 받는 치료 이외의 선량을 고려했을 때 가능한 B-mode 또는 낮은 촬영 조건을 설정하여 환자가 받는 치료이외선량을 가능한 한 줄일 필요가 있다고 사료된다.

  • PDF