• 제목/요약/키워드: repeated confidence intervals

검색결과 8건 처리시간 0.019초

Balanced Simultaneous Confidence Intervals in Logistic Regression Models

  • Lee, Kee-Won
    • Journal of the Korean Statistical Society
    • /
    • 제21권2호
    • /
    • pp.139-151
    • /
    • 1992
  • Simultaneous confidence intervals for the parameters in the logistic regression models with random regressors are considered. A method based on the bootstrap and its stochastic approximation will be developed. A key idea in using the bootstrap method to construct simultaneous confidence intervals is the concept of prepivoting which uses the transformation of a root by its estimated cumulative distribution function. Repeated use of prepivoting makes the overall coverage probability asymptotically correct and the coverage probabilities of the individual confidence statement asymptotically equal. This method is compared with ordinary asymptotic methods based on Scheffe's and Bonferroni's through Monte Carlo simulation.

  • PDF

Effects of an Infant Care Education Program for Mothers of Late-preterm Infants on Parenting Confidence, Breastfeeding Rates, and Infants' Growth and Readmission Rates

  • Jang, Eun Hye;Ju, Hyeon Ok
    • Child Health Nursing Research
    • /
    • 제26권1호
    • /
    • pp.11-22
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effects of an education program for mothers of late-preterm infants on parenting confidence, breastfeeding rate, and infants' growth and readmission rate. Methods: The participants were 53 mothers of late-preterm infants (26 in the experimental group and 27 in the control group). The experimental group was administered the late-preterm care education program while the control group received standard care. The program consisted of two sessions during hospitalization after birth, one session at the time of discharge, and telephone and social networking service consultations at weekly intervals for the month following discharge. The collected data were analyzed using the t-test, x2 test, and repeated-measures analysis of variance. Results: Parenting confidence and the breastfeeding rate were significantly higher in the experimental group than in the control group. However, there was no significant difference in the late-preterm infants' growth and readmission rates between the experimental and control groups. Conclusion: A care education program for mothers of late-preterm infants can be a useful nursing intervention in clinical practice.

Comparison of Parametric and Bootstrap Method in Bioequivalence Test

  • Ahn, Byung-Jin;Yim, Dong-Seok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제13권5호
    • /
    • pp.367-371
    • /
    • 2009
  • The estimation of 90% parametric confidence intervals (CIs) of mean AUC and Cmax ratios in bioequivalence (BE) tests are based upon the assumption that formulation effects in log-transformed data are normally distributed. To compare the parametric CIs with those obtained from nonparametric methods we performed repeated estimation of bootstrap-resampled datasets. The AUC and Cmax values from 3 archived datasets were used. BE tests on 1,000 resampled data sets from each archived dataset were performed using SAS (Enterprise Guide Ver.3). Bootstrap nonparametric 90% CIs of formulation effects were then compared with the parametric 90% CIs of the original datasets. The 90% CIs of formulation effects estimated from the 3 archived datasets were slightly different from nonparametric 90% CIs obtained from BE tests on resampled datasets. Histograms and density curves of formulation effects obtained from resampled datasets were similar to those of normal distribution. However, in 2 of 3 resampled log (AUC) datasets, the estimates of formulation effects did not follow the Gaussian distribution. Bias-corrected and accelerated (BCa) CIs, one of the nonparametric CIs of formulation effects, shifted outside the parametric 90% CIs of the archived datasets in these 2 non-normally distributed resampled log (AUC) datasets. Currently, the 80~125% rule based upon the parametric 90% CIs is widely accepted under the assumption of normally distributed formulation effects in log-transformed data. However, nonparametric CIs may be a better choice when data do not follow this assumption.

Monitoring of Clinical Trials: Issues and Recammendations

  • Fleming Thomas R.;Demets David L.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.270-284
    • /
    • 1994
  • Interim analyses of randomized trials enable investigators to make more efficient use of limited research resources and to satisfy ethical requirements that a regimen be discontinued as soon as it has been established to have an inferior efficacy/toxicity profile. Unfortunately. the integrity and credibility of these trials can be compromised if inappropriate procedures are used in monitoring interim data. 'In this paper we discuss how group sequential designs provide useful guidelines that enable one to satisfy the valid objectives of interim monitoring while avoiding undesirable consequences, and we consider how flexible one can be in the way such designs are implemented. We also provide motivation for the role of data-monitoring committees in preserving study integrity and credibility in either government- or industry-sponsored trials. In our view. these committees should have multidisciplinary representation and membership limited to individuals free of apparent significant conflict of interest, and ideally should be the only individuals to whom the data analysis center provides interim results on relative efficacy of treatment regimens. Finally. we discuss some important practical issues such as estimation following group sequential testing, anal ysis of secondary outcomes after using a group sequential design applied to a primary outcome, early stopping of negative trials. and the role of administrative analyses.

  • PDF

분말형 프로바이오틱스 섭취방법에 따른 구강 내 pH 변화 (Changes in pH values in the oral cavity according to the intake method of powdered probiotics)

  • 황영선;이민경;김명희
    • 한국치위생학회지
    • /
    • 제19권6호
    • /
    • pp.1099-1107
    • /
    • 2019
  • Objectives: The purpose of this study was to investigate the changes in pH in the oral cavity using the probiotic intake method. Methods: A total of 109 participants were enrolled and randomly assigned to three groups. Participants in the control group did not ingest powdered probiotics, those in experimental group 1 ingested powdered probiotics by dissolving them on the tongue, and those in experimental group 2 dissolved powdered probiotics on the tongue and rinsed with water. pH values were measured 5 times in all. The significance of each group was examined by the Kruskal-Wallis test. The trend over time was expressed as a graph with groupwise means and confidence intervals, considering repeated measurement data. Results: A significant difference was found between the control group and experimental group 1 at two time-points, i.e., immediately after intake and 3 min after ingestion. As a result of the time trend, the pH value of experimental group 2 was smaller than that of experimental group 1, compared to the control group. Conclusions: Studies have shown that taking probiotics with water may help reduce changes in oral pH. Probiotics should be aware of live bacteria and provide consumers with more detailed information on proper dosage and precautions.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Effects of Pre- and Post-workout Energy Bar Supplementation on Blood Lactate and Fitness in Young Adults with CrossFit Training: A randomized crossover study

  • Byung-Gul Lim;Xinxing Li;Wook Song
    • 대한통합의학회지
    • /
    • 제11권4호
    • /
    • pp.61-71
    • /
    • 2023
  • Purpose : Energy bars are increasingly popular among active individuals, yet their timing and nutrient combinations' impact on exercise adaptation remains unclear. This study aims to address this knowledge gap by investigating whether the combination of pre- and post-workout supplementation can synergistically enhance fitness and alleviate fatigue in trained CrossFit participants. Investigate if combining pre- and post-workout supplements can enhance fitness and blood lactate management in trained CrossFit participants, potentially improving exercise performance for this group. Methods : In a randomized crossover study, 20 trained CrossFit individuals (11 males, 9 females) completed thrice-weekly 60-minute CrossFit sessions for 3 weeks, with a one-week washout period. Participants were randomly assigned to either a chocolate bar group (CH, 45 g, 225 kcal) or an energy bar group (ES, 48 g, 238 kcal, with protein, caffeine, taurine, and BCAAs). For one week, participants consumed two bars of their assigned supplement five minutes before and after workouts. After a washout period, they switched supplements. Blood lactate levels and a visual analog scale (VAS) were assessed before, immediately after, and 30 minutes post-workout. Fitness tests (hand grip, broad jump, sit-ups) were conducted at baseline and 30 minutes post-final workout. Data were analyzed using two-way repeated measures ANOVA (p<.05), 95 % confidence intervals, and magnitude inferences. Results : Hand grip strength (t=-5.60, p=.000), broad jump (t=-3.43, p=.003) and sit up (t=-3.94, p=.001) were significantly increased in the ES group. Compared to CH group, there was a significant time and group interactions for blood lactate level (F=5.51, p=.008) and VAS(F=31.67, p=.000) in the ES group. Conclusion : Pre- and post-workout energy bar supplementation may have a beneficial effect on blood lactate clearance and fitness in trained CrossFit individual. The combination of proprietary supplements taken may provide benefits for removing the blood lactate during high-intensity functional exercise.

전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구 (The Accuracy of the Table Movement During a Whole Body Scan)

  • 이주영;정우영;정은미;동경래
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.86-91
    • /
    • 2009
  • 전신 영상 검사는 일반적인 핵의학 검사에 적용되고 있는 가장 기본적인 촬영 방법 중 하나이다. 이 때 각 검사마다 규정화된 테이블 이동 속도는 다양하다. 본 연구에서는 감마카메라의 사용 기간에 따른 노후 상태와 감마카메라 테이블 위의 무게 변화에 따른 테이블 이동 속도를 측정하여 그 정확성을 분석하는데 그 목적이 있다. 2008년 12월부터 2009년 2월까지 서울아산병원 핵의학과내에서 전신 영상 검사를 주로 시행하는 SIEMENS 장비 중 가장 사용기간이 긴 ECAM plus와 가장 최근에 설치된 SYMBIA T2를 대상으로 연구를 실시하였다. 각 장비별로 테이블 이동속도를 10, 15, 30 cm/min으로 나누어 매 10 cm씩 마다 총 100 cm의 구간을 타이머를 이용해 테이블 이동 시간을 측정하였다. 또한 표준 체중을 60~70 kg으로 감안하여 0, 66, 110 kg으로 나누어 체중에 따른 테이블의 이동 속도를 동일한 방법으로 측정하여 비교 분석하였다. 본 연구에서는 10 cm/min, 15 cm/min, 30 cm/min의 변동계수가 ECAM plus에서 1.23, 1.42, 2.02이었고, SYMBIA T2에서 1.23, 1.83, 2.28이었으며 테이블 이동속도가 증가될수록 변동은 많았다. 또한 무게 변화에 따른 각각의 변동계수는 0 kg에서 0.96, 1.45, 2.08이었고, 66 kg에서 1.32, 1.72, 2.27이며, 110 kg에서 1.37, 1.73, 2.14로 무게에 따른 큰 차이는 없었다. 95% 신뢰수준에서 통계적으로 유의한 차이는 있지 않아(p>0.05) 두 장비 모두 허용할 수 있는 범위안에 있었지만, ECAM plus에 비해 SYMBIA T2의 변동계수가 비교적 크게 측정되었다. 이러한 결과를 미루어 볼 때 Onco. Flash와 같은 Half-time 검사법을 실시하기 전에는 테이블의 이동과 테이블 이동 속도, 감마카메라의 상태를 점검하고, 좀 더 관심을 기울여야 하며 정기적인 점검을 일반화시키는 것이 유용할 것이라고 생각된다.

  • PDF