• 제목/요약/키워드: repaired beam

검색결과 74건 처리시간 0.022초

Improved analytical method for adhesive stresses in plated beam: Effect of shear deformation

  • Guenaneche, B.;Benyoucef, S.;Tounsi, A.;Adda Bedia, E.A.
    • Advances in concrete construction
    • /
    • 제7권3호
    • /
    • pp.151-166
    • /
    • 2019
  • This paper introduces a new efficient analytical method, based on shear deformations obtained with 2D elasticity theory approach, to perform an explicit closed-form solution for calculation the interfacial shear and normal stresses in plated RC beam. The materials of plate, necessary for the reinforcement of the beam, are in general made with fiber reinforced polymers (Carbon or Glass) or steel. The experimental tests showed that at the ends of the plate, high shear and normal stresses are developed, consequently a debonding phenomenon at this position produce a sudden failure of the soffit plate. The interfacial stresses play a significant role in understanding this premature debonding failure of such repaired structures. In order to efficiently model the calculation of the interfacial stresses we have integrated the effect of shear deformations using the equilibrium equations of the elasticity. The approach of this method includes stress-strain and strain-displacement relationships for the adhesive and adherends. The use of the stresses continuity conditions at interfaces between the adhesive and adherents, results pair of second-order and fourth-order coupled ordinary differential equations. The analytical solution for this coupled differential equations give new explicit closed-form solution including shear deformations effects. This new solution is indented for applications of all plated beam. Finally, numerical results obtained with this method are in agreement of the existing solutions and the experimental results.

Effect of tapered-end shape of FRP sheets on stress concentration in strengthened beams

  • Belakhdar, Khalil;Tounsi, Abdelouahed;Adda Bedia, El Abbes;Redha, Yeghnem
    • Steel and Composite Structures
    • /
    • 제11권6호
    • /
    • pp.435-454
    • /
    • 2011
  • Bonding composite materials to structural members for strengthening purpose has received a considerable attention in recent years. The major problem when using bonded FRP or steel plates to strengthen existing structures is the high interfacial stresses that may be built up near the plate ends which lead to premature failure of the structure. As a result, many researchers have developed several analytical methods to predict the interface performance of bonded repairs. In this paper, a numerical solution using finite - difference method is used to calculate the interfacial stress distribution in beams strengthened with FRP plate having a tapered ends with different thinning profiles. These latter, can significantly reduce the stress concentration. In the present theoretical analysis, the adherend shear deformations are taken into account by assuming a parabolic shear stress through the thickness of both beam and bonded plate. Numerical results from the present analysis are presented to demonstrate the advantages of use the tapers in design of strengthened beams.

광섬유 센서를 이용한 패치형 복합재료 보강 구조물에서의 진단기법에 관한 연구 (Study on the Self Diagnosis of Reinforced Concrete Beam Repaired by Patch Type Composite with Optical Fiber Sensors)

  • 이정근;한성도;엄진성;이정규;정철;김기수
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.1-4
    • /
    • 2003
  • 사회기반기설을 구축하는 다양한 토목·건축 분야의 주요 콘크리트 구조부재에 탄소섬유시트를 비롯한 섬유복합재료를 이용하여 보수·보강하는 공법은 최근에 세계적으로 많이 활용되고 있는 신공법 중에 하나이다. 기존의 보수·보강재료에 비해 섬유 복합재료에 의한 시공방법의 장점은 구조부재의 내하력을 증가시킬 수 있고 기존에 발생한 균열을 구속하는 효과를 얻을 수 있다. (중략)

  • PDF

균열이 발생된 콘크리트의 특성 및 보수.보강(구조 및 재료 \circled2) (Properties and Repair-Reinforcement of Concrete Introduced Crack)

  • 김영익;윤준노;민정기;김경태;박필우;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.284-289
    • /
    • 2000
  • This study is performed to evaluate an the crack properties and repair-reinforcement of concrete introduced crack. Materials used are portland cement, coarse aggregate, fine aggregate, unsaturated polyester resin and fly ash. Specimen is used beam of 76${\times}$76${\times}$412mm for measurement of pulse velocity, dynamic modulus of elasticity and bending strength and is introduced crack artificially. The following conclusions are drawn; Pulse velocity, dynamic modulus of elasticity and bending strength of concrete introduced crack is shown the lower 1.24∼11.91%, 3.42∼17.21% and 38.17∼61.0% than that of the control concrete, respectively. Pulse velocity, dynamic modulus of elasticity and bending strength of concrete repaired and reinforced crack is shown the higher 0.5∼2.60%, 1.57∼3.07% and 28.17∼47.25% than that of the concrete introduced crack and the lower than that of the control concrete, respectively.

  • PDF

펄스형 Nd:YAG 레이저빔을 이용한 인코넬 판재의 용접 특성 (Welding Characteristics of Inconel Plate Using Pulsed Nd : YAG Laser Beam)

  • 변진귀;박광수;한원진;심상한
    • 한국레이저가공학회지
    • /
    • 제3권1호
    • /
    • pp.12-20
    • /
    • 2000
  • The nuclear steam generators are subjected to corrosion environmental condition during operation that can result in stress corrosion in the tube wall. If any tube wall degradation is recognized, the tube must be repaired by plugging or sleeving. For the sleeving repair, Nd : YAG laser welded sleeving technology is one of the most promising when considering radioactive working conditions in the nuclear power plant. In this paper, the laser welding characteristics of steam generator tube and sleeve materials are investigated. The effects of average laser power, laser energy, welding speed, pulse duration and frequency are evaluated. Based on these results, Nd : YAG laser welded sleeving repair was applied to the degraded steam generator tubes in real environment.

  • PDF

헌치로 보강된 철골모멘트골조의 지진응답 사례연구 (A Case Study on Seismic Response of Haunch Repaired Steel MRFs)

  • 이철호
    • 한국지진공학회논문집
    • /
    • 제1권2호
    • /
    • pp.69-78
    • /
    • 1997
  • 철골 모멘트 접합부의 보 하부를 헌치로 보강하여 내진성을 크게 향상 시킬 수 있음이 최근의 실물대 보-기둥 "부분골조" 실험을 토하여 확인된 바 있다. 그러나 헌치보강에서 기인할 수 있는 부작용 (side effecs) 또는 보강구조체의 "시스템 레벨"의 거동에 관해서는 현재 잘알려진 것이 없다. 본 연구에서는 헌치보강시 생성되는 이중패널존의 거동을 해석과정에 반영하여 보강구조체의 시스템 레벨의 거동변화를 고찰하였다. 이중패널존의 모델링은 최근에 필자가 제시한 기법을 사용하였으며 1994년 노스리지 지진 당시 접합부 손상을 입은 13층 철골모멘트골조를 대상으로 연구를 수행하였다. 정적/동적 비선형해석에 의해 얻어진 원구조물과 부강구조물의 전체적 응답(global responses)은 큰 차이를 보이지 않았으며 취약층(weak story)의 촉진과 같은 유해한 부작용도 수반되지 않았다.은 유해한 부작용도 수반되지 않았다.

  • PDF

Repair of seismically damaged RC bridge bent with ductile steel bracing

  • Bazaez, Ramiro;Dusicka, Peter
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.745-757
    • /
    • 2018
  • The inclusion of a ductile steel bracing as means of repairing an earthquake-damaged bridge bent is evaluated and experimentally assessed for the purposes of restoring the damaged bent's strength and stiffness and further improving the energy dissipation capacity. The study is focused on substandard reinforced concrete multi-column bridge bents constructed in the 1950 to mid-1970 in the United States. These types of bents have numerous deficiencies making them susceptible to seismic damage. Large-scale experiments were used on a two-column reinforced concrete bent to impose considerable damage of the bent through increasing amplitude cyclic deformations. The damaged bent was then repaired by installing a ductile fuse steel brace in the form of a buckling-restrained brace in a diagonal configuration between the columns and using post-tensioned rods to strengthen the cap beam. The brace was secured to the bent using steel gusset plate brackets and post-installed adhesive anchors. The repaired bent was then subjected to increasing amplitude cyclic deformations to reassess the bent performance. A subassemblage test of a nominally identical steel brace was also conducted in an effort to quantify and isolate the ductile fuse behavior. The experimental data from these large-scale experiments were analyzed in terms of the hysteretic response, observed damage, internal member loads, as well as the overall stiffness and energy dissipation characteristics. The results of this study demonstrated the effectiveness of utilizing ductile steel bracing for restoring the bent and preventing further damage to the columns and cap beams while also improving the stiffness and energy dissipation characteristics.

Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations

  • Jeong, Ki-Won;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.95-104
    • /
    • 2019
  • PURPOSE. To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS. Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS. The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION. In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.

Numerical study of the seismic behavior of steel frame-tube structures with bolted web-connected replaceable shear links

  • Lian, Ming;Cheng, Qianqian;Zhang, Hao;Su, Mingzhou
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.305-325
    • /
    • 2020
  • Beams of steel frame-tube structures (SFTSs) typically have span-to-depth ratios of less than five. This makes a flexural beam unsuitable for such an application because the plastic hinges at the beam-ends cannot be adequately developed. This leads to lower ductility and energy dissipation capacities of SFTSs. To address this, SFTSs with bolted web-connected replaceable shear links (SFTS-BWSLs) are proposed. In this structural system, a web-connected replaceable shear link with a back-to-back double channel section is placed at the mid-length of the deep beam to act as a ductile fuse. This allows energy from earthquakes to be dissipated through link shear deformation. SFTS and SFTS-BWSL buildings were examined in this study. Several sub-structures were selected from each designed building and finite element models were established to study their respective hysteretic performance. The seismic behavior of each designed building was observed through static and dynamic analyses. The results indicate that the SFTS-BWSL and SFTS have similar initial lateral stiffness and shear leg properties. The SFTS-BWSL had lower strength, but higher ductility and energy dissipation capacities. Compared to the SFTS, the SFTS-BWSL had lower interstory drift, base shear force, and story shear force during earthquakes. This design approach could concentrate plasticity on the shear link while maintaining the residual interstory drift at less than 0.5%. The SFTS-BWSL is a reliable resistant system that can be repaired by replacing shear links damaged due to earthquakes.

일출목 초익공 공포의 기원과 변천 (The Origins and Changes of One Chulmok-One Ikgong Bracket-Sets in the Joseon Dynasty)

  • 전해완;류성룡
    • 건축역사연구
    • /
    • 제29권3호
    • /
    • pp.79-90
    • /
    • 2020
  • In Korean traditional architecture, the Gong-po style is divided into the Jusimpo, Dapo and Ikgong. Jusimpo and Chulmok-Ikong, where only Gong-po is placed on the column, differ in form of Gong-po depending on the viewpoint. Since 'Chulmok-Ikgong' has been generally regarded as 'One Chulmok-Two Ikgong', the precedent researches have been conducted mainly on 'One Chulmok-Two Ikgong' in the Gong-po style classification. However, when it comes to 'One Chulmok', the style of Ikgong can be organized from the one to three steps and this study is particularly for examining the occurrence and transformation of 'One Chulmok-One Ikgong'. One of the case study sites, Bonghwa Cheongamjeong was originally built in the 16th century, and is believed to have been repaired from 'Non Chulmok-One Ikgong' to 'One Chulmok-One Ikgong'. Since the beam linked directly to the upper part of a capital, it does not connect the eave trave(architrave) in between. Also, Soro which supports Jangyeo(the architrave strip) has been placed and linked in comparatively lower position. It is confirmed by the signigicant difference in the hierarchy of Gong-po forms in one architecture. The Jeonju-Hyanggyo Daeseongjeon, which was built in the 17th century among the subjects, was similar with 'One Chulmok-One Ikgong', but it was found to be the type of Jusimpo form because the bottom of the beam and the top of the Ikong are apart. And Gongan is confirmed at Cheomcha. In the 17th century, it can be seen that Heot-Cheomcha disappeared and Ikgong was started to use as a constant figure. The end of the 18th century, it can be seen that it was changed into a ornament added on Haeng-gong, being seen in the case of Hwaseong Dongjangdae. In conclusion, it can be seen that 'One Chulmok-One Ikgong' were developed in both the Jusimpo and Ikong style. The transformation into 'One Chulmok-One Ikgong' was inevitable consequence related with an elevation difference between the eave trave and the column trave.