• Title/Summary/Keyword: removal unit

Search Result 495, Processing Time 0.024 seconds

Pig slurry treatment by the pilot scale hybrid multi-stage unit system (HMUS) followed by sequencing batch reactor (SBR) (HMUS와 SBR 반응조를 이용한 축분처리에 관한 연구)

  • Lee, Young-Shin;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.2
    • /
    • pp.63-70
    • /
    • 2013
  • Experiments in a pilot-scale hybrid multi-stage unit system (HMUS) combination of ATAD and EGSB followed by SBR process for pig slurry treatment were conducted to demonstrate the feasibility of using autothermal thermophilic aerobic digestion (ATAD) and expended granular sludge bed (EGSB) followed by sequencing batch reactor (SBR) system. Contaminants in pig slurry with high organic matter, nitrogen (N) and phosphorus (P) content were completely removed in the combined process. The highest removal rate for CODcr among contaminants in the feed pig slurry was attained by about 43.3% in ATAD unit process. Also TS removal rate of 96.5% was attained and the highest in the next coagulation unit process. The highest removal rate of CODcr under operating parameter conditions of OLR(organic loading rate), 3-6Kg $COD/m^3{\cdot}day$ and line velocity, 1.5-4m/h was earned at 3days of HRT. The disinfection of pathogens was effective at 50,000mg/L of TS in ATAD unit process. Biogas production per organic removal was $2.3{\sim}8.5m^3/kgTS{\cdot}d$ (average $5.2m^3/kgTS{\cdot}d$) in EGSB unit process. The average removal rates of CODcr 71.7%, TS 64.1%, TN 45.9%, and TP 50.4% were earned in the intermittent aeration SBR unit process.

A study on the Analysis of Actual Condition of Residental Environment for the Eldery Residing in Daejeon (대전시 노인의 거주환경실태 조사연구)

  • 박정아;이지숙
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.175-183
    • /
    • 2004
  • The purpose of this study was to identify the actual condition of residential environment for the elderly residing in Daejeon. The data were collected through interviews and structured questionnaires. The sujects were 583 elderly people over the age of 65 in Daejeon. Sociodemographic characteristics, living characteristics, housing characteristics, neighborhood environment types, actual usage condition of neighborhood environment, relationship between sociodemographic characteristics and actual usage of neighborhood environment, actual condition of unit interior, were surveyed. The data were analyzed with frequency, percentage, χ²-test, mean using the SPSS package. The major findings were as follows. Features of unit interior which pointed generally were deterioration, soundproofing and size. Features of unit interior which need to be carefully planned were removal of height difference of entrance, removal of the thresholds, installation of emergency bell and room heating control facility. The facilities provided highly within the subject's residential environment were the eldery facility, church, hospital, bank, restaurant, beauty salon/barbershop, supermarket. and the facilities provided lowly were recreational facility, library, elderly school.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Development of a Rotating Biological Contactor(RBC) Process for the Advanced Wastewater Treatment (회전원판(回轉圓板) 생물막(生物膜) 공법(工法)을 이용한 하(下)·폐수(廢水)의 고도처리(高度處理) 공정(工程) 개발(開發))

  • Kim, Eung Ho;Park, Jae Lo;Yoon, Jung Ro
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1994
  • This study was conducted to develop a new RBC process available for the effective removal of organic matters and nitrogen in sewage. The RBC process for the oxidation organic compounds and nitrification was designed to occur at the 1st-stage and next-stage RBC respectively. Then nitrified water was recycled to the denitrifying RBC located at the lower part of the 1st-stage RBC. Some results were summarized as follows. 1. The loading limitation was represented as $60g{\cdot}COD/gm^2/day$ in experiment of simultaneous removal of organic matter and nitrogen. The maxmum COD % removal was 85% at the load $35g{\cdot}COD/m^2/day$. 2. The $NO_3-N$ % removal was approximately 80% at the load $60g{\cdot}COD/m^2/day$ and the maximum $NO_3-N$ remaval rate was $3.9g{\cdot}COD/m^2/day$ and the overall C/N ratio of 11.0 as required to achive 80% of $NO_3-N$% removal. 3.$NO_3-N$ removal rate was rapidly decreased above the load $7g{\cdot}NH_4{^+}-N/m^2/day$ and the maximum $NO_3-N$ removal rate was $3.7g{\cdot}NO_3-N/m^2/day$. 4. Irrespective of the recycle ratio, the COD % removal at the system of 2-stage RBC unit was nearly constant as 89% while the maximum one in the 1st-stage unit was 77% in the case of 50% recycle. 5. The maximum COD % removal in the 3-stage RBC system was 93% while 1st-stage one being 80%, under the $NH_4{^+}-N$ load of $7.4g/m^2{\cdot}d$. Also maximum percentage of nitrification and denitrification was 69% and 41% respectively, under the same $NH_4{^+}-N$ load.

  • PDF

The Development of Hemodialysis System Based on Embedded System (임베디드 시스템 기반의 혈액 투석기 시스템의 개발)

  • Ji, Jung-Ho;Lee, Kyoung-Joung;Kim, Young-Ho;Park, Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.521-527
    • /
    • 2002
  • The Hemodialysis system is the device for the patients who have suffered from end stage renal failure as the kidney which removes the waste products in a human body. The existing hemodialysis is based on a 8-bit micro-controller and it is not a touch-screen type but a manual type. This paper is focused on hemodialysis system based on high control and expension embedded system. The whole system consists of main control unit and sub control unit(dialysis control unit, blood control unit, monitoring control unit, networking unit). The dialysis control unit, blood control unit, monitoring control unit are processed by 3 microcontrollers and network unit is for monitoring a renal failure patient's condition. For the evaluation of the system performance, the saline was pured into blood unit and then water removal rate, conductivity and temperature of hemodialysis liquid were measured 10 times in an each state suing the UF pump in the fluid unit varing the quantity of saline to 1000cc, 2000cc, 3000cc and 4000cc. As a result, the rates of water removal are 98.6% in condition of 000cc saline, 96.9% in 2000cc, 98.9% in 3000cc and 98.3% in 4000cc. The conductivities of hemodialysis liquid are 99.6% in the first to third condition and 99.7% in the forth condition. The temperatures of hemodialysis liquid are 99.8% in the first to third condition and 99.6% in th forth condition.

A Study on Removal Efficiency of Cd by using Chitosan Complex isolated from Aspergillus oryzae (Aspergillus oryzae로부터 분리한 chitosan복합체에 의한 카드뮴 제거 효율에 관한 연구)

  • 장재선;이제만;김용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.1
    • /
    • pp.37-41
    • /
    • 2004
  • The removal efficiency of cadmium by chitosan complex isolated from Aspersillus oryzae was investigated through laboratory experiments. The results of the study are as follows. The adsorption kinetics of cadmium was reached the adsorption equilibrium in approximately 20 minutes and the removal efficiency was showed 95.8%. The effect of temperature on cadmium adsorption by chitosan complex shows that as the temperature increased, the amount of cadmium adsorption per unit weight of chitosan complex increased. The correlation between amount of cadmium adsorption per unit weight of chitosan complex and temperature was obtained through the coefficient of determination($R^2$). $R^2$ values was 0.854(p<0.05). A linearized Freundlich equation was used to fit the acquired experimental data. As a result, Freundlich constant, the adsorption intensity(1/n) was 0.550, and the measure of adsorption(k) was 2.181. So, it was concluded that adsorption of cadmium by chitosan complex is effective.

A Study on Corrective Polishing Using a Small Flat Type Polisher (소형 평면공구를 이용한 형상수정 폴리싱에 관한 연구)

  • Kim, Eui-Jung;Shin, Keun-Ha
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.99-106
    • /
    • 2002
  • For the development of a ultra-precision CNC polishing system including on-machine measurement system, we study a corrective polishing algorithm. We calculated unit removal profiles for various flat type polishing tools and polishing tool positions. Using these results we simulate the corrective polishing process based on dwell time control. We calculate dwell time distributions and residual error of the polishing simulation method and the FFT calculation method. We test corrective polishing algorithm with an optical glass. The target removal shape is a sine wave that has amplitude 0.3 micro meters. We find this polishing process has a machining resolution of nanometer order and is effective for sub-micrometer order machining. This result will be used for the software development of the CNC polishing system.

MBR technology for textile wastewater treatment: First experience in Bangladesh

  • Saha, Pradip;Hossain, Md. Zakir;Mozumder, Md. Salatul I.;Uddin, Md. Tamez;Islam, Md. Akhtarul;Hoinkis, Jan;Deowan, Shamim A.;Drioli, Enrico;Figoli, Alberto
    • Membrane and Water Treatment
    • /
    • v.5 no.3
    • /
    • pp.197-205
    • /
    • 2014
  • For the first time in Bangladesh, a bench scale membrane bioreactor (MBR) unit was tested in treating a textile wastewater in the industry premises of EOS Textile Mills LTD, Dhaka for three months. The performance of the unit was compared with that of the conventional activated sludge treatment plant, which is in operation in the same premises. The COD and BOD removal efficiency of the MBR unit reached to around 90% and 80% respectively in 20 days whereas the removal efficiency of the conventional treatment plant was as low as 40-50% and 38-40% respectively. The outlet COD and the BOD level for the MBR unit remained stable in spite of the fluctuation in the feed value, while the conventional effluent treatment plant (ETP) failed to keep any stabilized level. The performance of the MBR unit was much superior to that of the functional ETP and the water treated by the MBR system can meet disposal standard.

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

STUDIES ON FARMER HOUSEHOLD LEVEL SOLAR GREENHOUSE DRYING UNIT

  • Chen, Yu-Bai;Liu, Dao-Bei
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.912-921
    • /
    • 1993
  • A small scale solar greenhouse tray dryer suitable for one or few farmer households is designed in place of sunny ground to dry various agricultural products. The tests on the drying of paddy, groundnut and radish slices by this drying unit have been made. The results indicated that this drying unit had a good heat collecting property, a low heat consumption (4518.7-5676.1 KJ per kg water removal) , a high heat utilizing efficiency (43.75%-54,25%) , a low operation cost (0.057 kwh-0.078 kwh per kg water removal) and good drying quality.

  • PDF