• 제목/요약/키워드: removal system

검색결과 3,552건 처리시간 0.034초

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Removal Nitrogen and Phosphorus using Intelligent auto control system

  • Kim, Young-Gyu;Chong, Young-Guin
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.147-149
    • /
    • 2003
  • Automatic monitoring and controling system, especially DO and MLSS was faciliated for the nitrogen and phosphorus removal efficiencies. Removal efficiency of nitrogen and phosphorus by automatic monitoring and controling system, especially DO and SRT was have well adopted. and so it will be possible to use artificial intelligence logic control software such as fuzzy or neuro logic control system for WWT Plant.

  • PDF

건식 흡착제를 이용한 차량용 이산화탄소 저감장치 개발 ($CO_2$ removal system by dry sorbent for passenger train)

  • 조용대;이주열;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1735-1739
    • /
    • 2008
  • Malfunction or inappropriate management of ventilation system in public transportation may cause unpleasant atmosphere or health problems to the old or feeble passengers. In this work, gaseous carbon dioxide removal system is developed and tested under the various serviced passenger cabins. Finally an optimum operating conditions for the $CO_2$ removal system will presented.

  • PDF

동물세포 배양액으로부터 암모늄 이온의 동시제거를 위한 고정화 흡착제의 개발과 동물세포 배양 시스템에의 응용 : II. 세포배양 시스템에의 응용 (Development of an Immobilized Adsorbent for In Situ Removal of Ammonium Ion from Animal Cell Culture Media and Its Applications to Animal Cell Culture System : II. Application to Cell Culture System)

  • 박병곤;이해익;전계택;김익환;정연호
    • KSBB Journal
    • /
    • 제13권4호
    • /
    • pp.411-417
    • /
    • 1998
  • The possibility of application of membrane type immobilized adsorbent to the fed-batch or perfusion culture system with anchorage-independent cells as well as batch system was investigated. The improvement in cell density and cell viability due to the combination of immobilized adsorbent with each culture system was evaluated for the investigation, and the optimum culture system employing immobilized adsorbent system was suggested based on the results. It was observed that the system with immobilized adsorbent showed better cell growth and cell viability than that without immobilized adsorbent in every operation system of batch, fed-batch, and perfusion. In case of batch system, 200% improvement of maximum cell density was observed in the system where ammonium chloride was added on purpose. And 50% improvement of maximum cell density was observed in the fed-batch system where ammonium ion accumulates significantly, while small increase in maximum cell density was observed in the perfusion system where dilution of waste byproducts exists. Especially, the fed-batch system showed the most significant improvement on cell growth because both compensation of nutrient and removal of ammonium ion occurred simultaneously in the system. Therefore a combined system of immobilized adsorbent and fed-batch operation could be suggested as an optimum system with in situ removal of ammonium ion.

  • PDF

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

현무암쇄석을 충진한 토양피복형 접촉산화공정의 오염물질제거효율에 관한 연구 (Efficiency of Nutrients Removal in a Microbial Contact Oxidation System Covered with Soil)

  • 최철호;이승목;윤종화;황필기;김정용
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.92-98
    • /
    • 2005
  • Nutrients removal performance of a contact oxidation reactor covered with soil was investigated when basalt rubble was used as a contact medium under various operating conditions. The objective of the experiment was to determine the effectiveness of the system by measuring the removal efficiencies of nutrients from a technical and economical viewpoint. Under the ranges of HRT(20 and 40 hrs) in the experiment, the removal rates of organic matter were as high as 97.5% by showing an effluent $BOD_5$ of less than 10 mg/L. The test of nitrogen removal when the turf was planted on the top soil showed that the average removal rate increased as much as 25% as compared to that without planting. It was suggested that the construction and maintenance cost could be reduced over 20% when the HRT of the system was decreased from 72 to 40 hrs.

오염처리장의 처리효율 개선연구 (A Study on Improvement of Sewage Treatment System)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

질소제거공정과 결합한 2상 혐기성 소화공정에서 돈분폐수의 메탄생성 및 질소제거 (Methane Production and Nitrogen Removal from Piggery Wastewater in the TPAD Coupled with BNR Process)

  • 박노백;박상민;최우영;전항배
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.18-25
    • /
    • 2009
  • Nitrogen removal and methane production from piggery wastewater were investigated in two-phase anaerobic digestion (TPAD) coupled with biological nitrogen removal (BNR) process at $35^{\circ}C$. Methane production rate was about $0.7L/L{\cdot}day$ at organic loading rate (OLR) of $1.2g{\cdot}TCOD/L{\cdot}day$ in methanogenic UASB. Conversion efficiency of the removed TCOD into methane in UASB was as high as 72% and overall TCOD removal efficiency in this system was over 97%. Ammonia nitrogen were stably removed in BNR system and overall efficiency were 98%. With recirculation of the nitrified final effluent to TPAD, nitrogen oxides were completely removed by anaerobic denitrification in the acidogenic reactor, which did not inhibit the acidogenic activities. Overall TN removal efficiency in the TPAD-BNR system was as high as 94%.

충진제의 종류에 따른 습식 스크러버의 가스상 물질 제거특성 (Removal Characteristics of Gaseous Contaminants by a Wet Scrubber with Different Packing Materials)

  • 한방우;김학준;김용진;한경수
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.744-751
    • /
    • 2007
  • Wet scrubber is widely used to remove toxic gaseous contaminants in various industries such as semi-conductor industry, display manufacturing industry and so on. In this study, to optimize a packed bed scrubber as one of typical wet scrubber size while keeping its performance, four different packing materials were investigated at different air flow rates, liquid-gas ratios and pH values. Ammonia, hydrochloric acid and hydrofluoric acid were used as test gases to characterize the scrubber performance. Gas removal efficiency increased as the packing size decreased, which resulted in the increase of specific surface area. The increase of air flow rate led to the decrease of gas removal efficiency, while the increase of liquid-gas ratio led to the increase of gas removal efficiency. For the case of $NH_3$ gas, lower pH, and for the cases of HCl and HF, higher pH contributed to higher gas removal efficiency. Gas removal efficiency of a wet scrubber increased in the order of HCl < $NH_3$ < HF according to its water solubility.

생물전기화학기술을 이용한 하수처리장 방류수 수질개선 가능성 (Potential of a Bioelectrochemical Technology for the Polishing of Domestic Wastewater Treatment Plant Effluent)

  • 송영채;오경근
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.351-359
    • /
    • 2015
  • The study on the improvement of discharge water quality from domestic wastewater treatment plant (DWTP) was performed in a filter type bioelectrochemical system. The COD removal efficiency for a synthetic discharge water was about 88%, and the effluent COD was less than 5mg/L. The nitrification efficiency of the bioelectrochemical system was over 97%, but a considerable amount of the nitrogen was remained as nitrate form in the effluent. The total nitrogen removal efficiency was only around 30%. There are no significant differences in the removal of COD and nitrogen at 0.6 and 0.8V of the applied voltages between anode and cathode. The removal of COD and nitrogen in the system were quite stable when the HRT ranged from 60 to 15 minutes, and at 10 minutes of HRT, the nitrification efficiency was slightly decreased. The performance of the bioelectrochemical system has quickly recovered from the shocks in the influent due to high concentration of COD and nitrogen. For the effluent that discharged from the DWTP, the removal efficiencies of COD and total nitrogen from the bioelectrochemical system were 50 and 30%, respectively. Thus the bioelectrochemical system was a feasible process for further polishing the effluent quality from DWTP.