• Title/Summary/Keyword: removal of column

Search Result 543, Processing Time 0.024 seconds

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

A Bioreactor for the Effective Removal of the Hydrogen Sulfide from Biogas (바이오가스에 포함된 고농도 황화수소의 효율적 제거를 위한 미생물반응기)

  • Namgung, Hyeong-Kyu;Yoon, Chang No;Song, JiHyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • A two-stage bioreactor system using sulfur-oxidizing bacteria was studied to abate high strength hydrogen sulfide ($H_2S$) from biogas. The two-stage bioreactor consisted of a $H_2S$ absorption column (0.5 L) and a microbial oxidation column (1 L) in series, and the liquid medium was continuously recirculated through the columns. The objectives of this study were to determine the feasibility of the bioreactor for biogas desulfurization and to investigate the effect of the medium circulation rate on the system performance. An averaged concentration of $H_2S$ introduced to the bioreactor was 530 ppm, corresponding to an overall loading rate of $44.4g/m^3/hr$. During the initial 20 days period at the medium recirculation rate of 8 reactor volumes per hour (12 L/hr), the dissolved oxygen (DO) concentration in the oxidation column was 6 mg/L, while the DO in the absorption column was 0.5 mg/L showing that the oxygen contents of the biogas stream was not altered. Because of the biological oxidation of $H_2S$ in the oxidation column, the sulfate concentration increased from 200 mg/L to 5,600 mg/L in the liquid medium. The removal efficiency of $H_2S$ was greater than 99% in the initial operation period. After the initial period, the medium recirculation rate between the two columns was stepwise changed eight times from 1.0 to 40 vol/hr (1.5~60 L/hr). At the recirculation rate of faster than 4 vol/hr, the $H_2S$ removal efficiencies were found to be high, but the efficiency declined at the lower recirculation rates than the threshold.

Effect of base isolation systems on increasing the resistance of structures subjected to progressive collapse

  • Tavakoli, Hamid R.;Naghavi, Fahime;Goltabar, Ali R.
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.639-656
    • /
    • 2015
  • Seismic isolation devices are commonly used to mitigate damages caused by seismic responses of structures. More damages are created due to progressive collapse in structures. Therefore, evaluating the impact of the isolation systems to enhance progressive collapse-resisting capacity is very important. In this study, the effect of lead rubber bearing isolation system to increase the resistance of structures against progressive collapse was evaluated. Concrete moment resisting frames were used in both the fixed and base-isolated model structures. Then, progressive collapse-resisting capacity of frames was investigated using the push down nonlinear static analysis under gravity loads that specified in GSA guideline. Nonlinear dynamic analysis was performed to consider dynamic effects column removal under earthquake. The results of the push down analysis are highly dependent on location of removal column and floor number of buildings. Also, seismic isolation system does not play an effective role in increasing the progressive collapse-resisting capacities of structures under gravity loads. Base isolation helps to localize failures and prevented from spreading it to intact span under seismic loads.

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Optimization of Zero-valent Iron Technology for Color Removal from Real Dye Wastewater (염색폐수 색도 제거를 위한 영가철 기술 최적화)

  • Lee, Jae Woo;Oh, Young Khee;Cha, Daniel K.;Lee, Taewon;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.758-763
    • /
    • 2009
  • This study presents the optimal conditions of zero-valent iron (ZVI) pretreatment for color removal from real dye wastewater. Removal of color by ZVI was strongly subject to the acidity of the wastewater buffering the pH increased after ZVI reduction. The real dye wastewater did not contain a sufficient amount of acidity and thus it was necessary to supplement acid to the dye wastewater before treatment. In continuous operation of iron column, the empty bed contact time (EBCT) and initial pH were varied to find the optimal conditions. A non-linear regression model fitted well the experimental result predicting that the optimal EBCT and pH for 80% removal efficiency was present in the range of 57~90 and 5~5.9, respectively. Color of column effluents could be further removed in the following biological oxidation step and the biodegradability of wastewater was also enhanced after iron pretreatment.

Studies on Cd and Removal Ability and Detoxification of Oenanthe stolonifera (미나리 ( Oenanthe stolonifera ) 의 Cd, Zn 제거능과 내성에 관한 연구)

  • Lee Soo;In Sook Lee
    • The Korean Journal of Ecology
    • /
    • v.19 no.6
    • /
    • pp.519-527
    • /
    • 1996
  • To examine the possibility of biomonitoring of heavy metal removal ability and soil, a study was performed to investigate the heavy metal removal ability and metal-binding protein (MBP) as detoxification process using Oenanthe stolonifera. After O. stolonifera was exposed to individuals (cadmium, zinc) and mixture (cadmium+zinc)for 4 days, removal rate of heavy metal and pH in the treatment medium was measured. MBP was assayed by means of ion exchange column chromatography. The exposure to mixture (Cd:76.8%, Zn:75%) rather than individuals (Cd:82.9%, Zn:90.4%) showed a synergism raising the toxic effect. Initial removal rate was different for each heavy metal : in case of exposure to cadmium it was over 60% on day 1, while for zinc it was 75~90% on day 4. Throughout the experimental period, pH value of treatment medium continuously decreased, since cortex in the roots may secret organic acid to adjust and prevent toxicity of metals. The existence or MBP in the 70~80 fraction and the presence of Zn-enzyme pool was ascertained with the column chromatography. This study demonstrated a possibility that heavy utilized as a biomarker of heavy metal pollution.

  • PDF

Removal of Cesium and Cobalt within Soil around TRIGA Reactor by Electrokinetic method (동전기적방법을 이용한 TRIGA 연구로 주변 토양내의 세습과 코발트 제거)

  • 김계남;원희준;정종헌;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.13-23
    • /
    • 2004
  • The characteristics of cesium and cobalt removal from soil around the TRIGA reactor using the electrokinetic method were analyzed and a device to restrain the pH increase in the soil column was suggested. When a NaCl solution was used as the electrolyte to raise the electric field strength, a precipitate was formed in the cathode in the soil column, resulting in a low removal efficiency. Thus, an acetate buffer solution (compound solution of $CH_3COONa$ and $CH_3COOH$) was injected into the soil column and acetic acid was periodically infected into the cathode reservoir to restrain any pH increase. Many $Cs^{2+}$ and $Co^{2+}$ ions were transferred by electromigration rather than electroosmosis during the initial remediation period, and no precipitate was formed in the soil column. 96% of the total amount of cesium in the soil column was removed after 5.9 days, while 94% of the total amount of cobalt was removed. Furthermore, the residual concentrations predicted by the developed model were similar to those obtained by experiment.

  • PDF

An Analysis of the Ageing Effect on the Removal of Cesium and Cobalt from Radioactive Soil by the Electrokinetic Method

  • Kim Gye-Nam;Oh Won-Zin;Won Hui-Zun;Jung Chong-Hun
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.304-315
    • /
    • 2004
  • The ageing effects of radionuclides in radioactive soil on remediation using the electrokinetic method were analyzed. Comparative experiments were conducted for the reactive soil around a TRIGA research? reactor contaminated with $^{137}Cs\;and\;^{60}Co$ for 15 years and the non-reactive soil that was intentionally contaminated with $Cs^+\;and\;Co^{2+}$ for 3 days. It was observed that because of an aging effect on $^{137}Cs$, the efficiency of removing it decreased. $H_{2}SO_4$ used as an additive to increase the removal efficiency showed a higher removal capability than other chemicals for both $^{137}Cs\;and\;^{60}Co$. The efficiency of removing radionuclides from the radioactive soil in the column was proportional to the capability of the added chemical to extract radionuclides. It took 10 days to achieve a $54\%$ removal of $^{137}Cs$ and a $97\%$ removal of $^{60}Co$ from the soil. The volume of the soil wastewater discharged from the soil column by the electrokinetic method was $20\%$ below that for soil washing.

Numerical study of progressive collapse in reinforced concrete frames with FRP under column removal

  • Esfandiari, J.;Latifi, M.K.
    • Advances in concrete construction
    • /
    • v.8 no.3
    • /
    • pp.165-172
    • /
    • 2019
  • Progressive collapse is one of the factors which if not predicted at the time of structure plan; its occurrence will lead to catastrophic damages. Through having a glance over important structures chronicles in the world, we will notice that the reason of their collapse is a minor damage in structure caused by an accident like a terrorist attack, smashing a vehicle, fire, gas explosion, construction flaws and its expanding. Progressive collapse includes expanding rudimentary rupture from one part to another which leads to total collapse of a structure or a major part it. This study examines the progressive collapse of a 5-story concrete building with three column eliminating scenarios, including the removal of the corner, side and middle columns with the ABAQUS software. Then the beams and the bottom of the concrete slab were reinforced by (reinforcement of carbon fiber reinforced polymer) FRP and then the structure was re-analyzed. The results of the analysis show that the reinforcement of carbon fiber reinforced polymer sheets is one of the effective ways to rehabilitate and reduce the progressive collapse in concrete structures.

Continuous Deodorization of Malodorous Sulfur Compounds Using Immobilized Riohacillus neapolitanuts R-10 (고정화 Thiobacillus neapolitanus R-10를 이용한 유황계 악취물질의 연속제거)

  • 원용돈;박상보
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.295-301
    • /
    • 1995
  • Continuous deodorization of malodorous sulfur compounds by Thiobaillus neapolitanusts R-10 immobilized onto a polypropylene pellet was studied using a column reactor at 30$^{\circ}$C. The maximum amounts of immobilized cells was 5.3 gall polypropylene with 5$\times$7.5mm in pellet size, and the amounts of immobilized cells in the higher part of the column was as twice as in the lower part. The optimum pH and temperature for removal of dimethyl sulfide were 6.0 and 30$^{\circ}$C, respectively. When 5-20 ${mu}ell$/l of hydrogen sulfide and methylmercaptan were employed 98% of removal efficiency were achieved. In contrast, lower concentrations of dimethyl sulfide and dimethyldisulfide should be supplied to meet satisfactory deodorization efficiency. The immobilized cell column was successfully operated for the deodorization of mixture of sulfur compounds over 15 days without significant loss of initial activity achieving high efficiency.

  • PDF