• 제목/요약/키워드: removal efficiency evaluation

검색결과 313건 처리시간 0.028초

Evaluation of effective process for oxidation and coagulation by ferrous ion and hydrogen peroxide

  • Moon, H.J.;Kim, Y.M.;Lee, S.H.
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 가을 학술발표회 발표논문집
    • /
    • pp.319-321
    • /
    • 2003
  • This research was carried out to evaluate the removal efficiencies of CODcr and colour for the dyeing wastewater by ferrous solution in Fenton process. The results showed that COD was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand colour was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of CODcr and colour was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However the final removal efficiency of COD and colour was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

  • PDF

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • 한국환경과학회지
    • /
    • 제13권11호
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구 (Performance and reusability of certified and uncertified face masks)

  • 이해범;김서정;주흥수;조희주;박기홍
    • 한국입자에어로졸학회지
    • /
    • 제15권4호
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

Al 함량이 다른 PAC를 이용한 응집 조건 별 인 제거효율 평가 (Evaluation of Phosphorus Removal Efficiency at Various Coagulation Conditions Using Polyaluminum Chloride with Different Al Contents)

  • 최정학;윤건곤;이창한
    • 한국환경과학회지
    • /
    • 제32권10호
    • /
    • pp.731-739
    • /
    • 2023
  • In this study, lab-scale phosphorus coagulation/precipitation experiments were performed using three types of polyaluminum chloride (PAC) with different Al contents (10%, 12%, and 17%). The PO4-P removal efficiencies at various operating conditions, such as initial PO4-P concentration, initial pH, and Al/P molar ratio, were evaluated, and correlations among the operating factors affecting phosphorus coagulation/precipitation with PAC were derived to optimize the process efficiency. When the initial PO4-P concentration was 0.065 and 0.161 mmol P/L under an initial pH of 8-10, the optimal PAC dose was 0.126-0.378 and 0.189-0.667 mmol Al/L, respectively. Under these conditions, the Al/P molar ratio was 2.16-6.18 and 1.28-4.30, respectively, and the PO4-P removal efficiency was in the range of 40.2-92.5%. When the Al/P molar ratio was 2 or less under an initial pH condition of 6-8, the PO4-P removal efficiency was approximately ≤40% owing to insufficient Al3+ ions. However, when the Al/P molar ratio is 3-5, the PO4-P removal efficiency improved to approximately 80-90%. Thus, the optimal Al/P molar ratio to achieve a PO4-P removal efficiency of over 90% was determined to be approximately 4 in the PO4-P coagulation/precipitation process using PAC.

시화호 인공습지에서 시공간적 수질분포 및 오염물질 제거효율 평가 (Temporal and Spacial Distributions of Water Quality and Evaluation of Pollutant Removal Efficiency in the Sihwa Constructed Wetland)

  • 최돈혁;최광순;김동섭;김세원;최동호;황인서;이윤경;강호
    • 대한환경공학회지
    • /
    • 제30권10호
    • /
    • pp.1013-1020
    • /
    • 2008
  • 시화호 인공습지의 오염물질 제거효율을 분석평가하고 수질정화기능의 저하원인을 파악하기 위하여 습지내 16개 지점에서 시공간적 수질분포에 대해 조사하였다. TN을 제외한 오염물질 제거효율은 조성 초기에 비해 낮아졌으며, 계절변동 또한 매우 큰 것으로 나타났다. 특히 BOD와 TP의 평균 제거효율이 각각 12.3%, -44.5%로 낮고, TN과 SS에 비해 계절변동이 큰 것으로 나타났다. 월평균 BOD의 제거효율은 습지 하류부에서 식물플랑크톤이 대량 증식하였던 4월과 7월에 처리효율이 나타나지 않았으며, TP의 경우는 4월부터 8월까지 제거효율이 지속적으로 감소하였으며 수온이 가장 높았던 8월에 -291%를 나타냈다. 폐쇄수역에서 SS 농도분포는 좌안과 우안에 비해 중앙지점에서 높은 것으로 나타났다. 또한 ANOVA test로부터 수평적으로 유의적인 차이(p = 0.013, 중앙 > 좌안 > 우안)를 보였다. 시화호 인공습지에서 오염물질 제거효율의 저하원인은 과도한 유기물 생산에 의한 습지의 혐기성환경과 이에 따른 습지 하류부에서 용출된 인과 대량 증식한 식물플랑크톤이 균등하지 못한 물 흐름에 의해 식생대를 거치지 않고 유출되었기 때문으로 유추된다.

Study of Catalytic Ceramic Fiber Filter Elements for Hot Gas Filtration

  • Young Jin Choi;Min Jin Park;Jun Suk Hong;Min Sun Hong;Jae Chun Lee
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.284-287
    • /
    • 1999
  • CuO catalyst-coated alumino-silicate fiber filters were prepared for the simultaneous removal of particulate matter and gaseous contaminants such as NOx and SOx. Hot gas cleaning experiments similar to Shell UOP process other than the catalyst supporting materials were carried out between 300 and $500^{\circ}C$ for the evaluation of the gas removal efficiency of the catalytic filter. Experimental results showed that removel efficiency for $SO_2$ was greater than 99% in the temperature range 450~$500^{\circ}C$ and more than 90% of NO was collected between 350 and $370^{\circ}C$. It was found that the higher the CuO content, the higher the removal efficiency for $SO_2$. Removal efficiency for NO was more affected by the gas cleaning temperature than by the CuO content in the catalyst-filter.

  • PDF

하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가 (Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks)

  • 한상무;김도형;정병곤
    • 한국물환경학회지
    • /
    • 제37권5호
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.

Evaluation of Field Applicability of Phosphorus Removal Capability and Growth of Bacillus sp. 3434 BRRJ According to Environmental Factors

  • Yoo, Jin;Kim, Deok-Hyun;Chung, Keun-Yook
    • 한국토양비료학회지
    • /
    • 제49권1호
    • /
    • pp.87-92
    • /
    • 2016
  • With the population growth and industrialization, the characteristics of discharged waste water and sewage have become more diverse. The removal of phosphorus (P) in the wastewater is essential for the prevention of eutrophication in the river and stream. This study was performed in order to estimate the field application of the Bacillus sp. 3434 BRRJ. Bacillus sp. 3434 BRRJ was cultured in the raw wastewater and synthetic medium at the 5 L reactor. The best optimum conditions for P removal by Bacillus sp. 3434BRRJ in the synthetic medium at the 5 L reactor were as follows: temperature, $30^{\circ}C$; P concentration, 20 mg/L; carbon sources, glucose + acetate (1:1); oxygen concentration, alternatively anaerobic and aerobic conditions. P removal efficiency under the optimum condition was 89.4%. In case of wastewater, P removal efficiency was 95.5% under controlled at $30^{\circ}C$. Through this study we confirmed that P removal by Bacillus sp. 3434BRRJ in case of wastewater was as effective as the synthetic medium. It is considered that Bacillus sp. 3434 BRRJ can be applied to the treatment of wastewater in order to biologically remove P from the wastewater on a large scale.

4단 간헐포기 공정의 운전조건이 고도처리에 미치는 영향 (Effect of Advanced Wastewater Treatment by Variations Operating Conditions of 4-stage Intermittently Aerated Activated Sludge process)

  • 최용범;이정규;한동준;권재혁
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.970-976
    • /
    • 2013
  • 본 연구는 간헐포기 공정을 이용하여 생활하수의 고도처리 효율을 증진시키는 방안을 제시하고자 수행되었다. 운전기간동안 유기물 제거효율 검토 결과, HRT 9hr 이상에서 TCODcr와 TBOD의 제거효율은 각각 91.1~96.3%와 91.4~97.5%로 높은 제거효율을 나타냈으나, HRT가 6hr에서는 각각 86.9~90.5%, 88.0~90.9%로 제거효율이 감소된 것으로 조사되었다. $NH_3$-N은 HRT 9hr 이상에서는 95% 이상의 높은 제거효율을 나타냈으며, T-N 제거효율은 HRT 9~12hr에서 67.6~76.7%, HRT 6hr에서는 50%로 감소되었는데 이는 탈질에 필요한 탄소원이 부족하기 때문이다. 운전기간동안 T-P 제거효율은 평균 32%로 낮게 조사되었는데 강화되는 법적기준을 준수하기 위해서는 반응조 후단에 화학적 인 제거 공정이 필요한 것으로 사료된다.

활성탄 흡착공정에 의한 과불화화합물의 제거 및 활성탄 자동재생 성능 평가 (Evaluation of perfluorinated compounds removal performance and automatic regeneration performance by activated carbon adsorption process)

  • 정진호;이상훈;윤원상;최대희;정진영;한인섭
    • 상하수도학회지
    • /
    • 제36권2호
    • /
    • pp.121-134
    • /
    • 2022
  • In this study, the removal efficiency of PFCs(perfluorinated compounds) in the GAC(granule activated carbon) process based on the superheated steam automatic regeneration system was investigated in laboratory scale and pilot-scale reactor. Among PFCs, PFHxS(perfluorohexyl sulfonate) was most effectively removed. The removal efficiency of PFCs was found to be closely related to the EBCT, and the removal efficiencies of PFOA(perfluorooctanoic acid), PFOS(perfluorooctyl sulfonate), and PFHxS were 43.7, 75, and 100%, respectively, under the condition of EBCT of 6 min. Afterward, PFOA, PFOS, and PFHxS exhibited the earlier breakthrough time in the order. After that, GAC was regenerated, and the removal efficiency of the PFCs before and after regeneration was compared. As a result, it was shown that the PFCs removal efficiency in the regenerated GAC process were higher, and that of PFOA was improved to 75%. The findings of this study indicate the feasibility of the superheated steam automatic regeneration system for the stable removal of the PFCs, and it was verified that this technology can be applied stably enough even in field conditions.