• Title/Summary/Keyword: removal effect

Search Result 3,161, Processing Time 0.039 seconds

Chemical Precipitation Treatment for the Disperse Dyes Removal (분산성 염료의 제거를 위한 응집처리)

  • 한명호;박종득;허만우
    • Textile Coloration and Finishing
    • /
    • v.14 no.2
    • /
    • pp.40-50
    • /
    • 2002
  • In order to remove the pollutants effectively in the dye wastewater by chemical precipitation process, coagulation arid flocculation test were carried out using several coagulants on various reaction conditions. It was found that the Ferrous sulfate was the most effective coagulant for the removal of disperse dye(B79), and we could get the best result lot the removal of disperse dye(B56) in the aspects of TOC removal efficiency and sludge field. When the Ferrous sulfate dosage was $800mg/\ell$, the sludge settling velocity was very fast>, and the color was effectively removed in the disperse dye(B79) solution. Although the color removal was ineffective when the Alum was used as a coagulant, the sludge field was decreased in comparison with the Ferrous sulfate or the Ferric sulfate was used in the disperse dye(B56) solution. The general color removal effect for the disperse dye(B56 and B79) solutions, the Ferric sulfate was more proper coagulant than the Alum. It was showed that TOC removal was improved 5% and over by the addition of Calcium hydroxide, and $30mg/\ell$ of sludge yield was decreased(B79). When Alum or Ferric sulfate was used as a coagulant, pH condition for most effective color removal was 5 in B56 solution. In case of Ferrous sulfate as a coagulant, most effective pH condition for color removal was 9. When Ferric sulfate or Ferrous sulfate was used as a coagulant, pH condition for most effective color removal was 9 in B79 solution.

Development on the Process for Nitrogen and Phosphorus Removal in Municipal Wastewater Treatment System

  • Kim, Young-Gyu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.144-146
    • /
    • 2003
  • The removal effect of total nitrogen in municipal wastewater by decreasing hydraulic retention time(HRT) from 6 hour to 4 hour on MNR process was not decreased.. The removal efficiencies of nutrient removal process combining A2/O process with media for T-N were 63.1% in the reactor operated 6 hour, and 73.5% in the reactor operated 5 hour and 77.0% in the reactor operated 4 hour.

  • PDF

Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater (ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

Variation of Phosphorus and Nitrogen Removal Characteristics According to the Decrease of Influent Phosphorus Concentration in SBR and SBBR (SBR과 SBBR에서 유입 인 농도 감소에 따른 인과 질소의 제거 특성 변화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2010
  • The purpose of this study is to investigate the effect of influent phosphorus concentration on the nitrogen and phosphorus removal in sequencing batch reactor(SBR) and sequencing batch biofilm reactors(SBBRs) in order to recover the enhanced biological phosphorus removal (EBPR) capacity at the sludge of the deterioration of EBPR capacity. In SBBRs, comparing to SBR, the organic removal was occurred actively at the 1 st non-aeration period because of the active phosphorus release at this period. However, the variation of TOC removal according to the decrease of influent phosphorus concentration was not clearly shown both in SBR and SBBRs. In case of SBR losing EBPR capacity, the EBPR capacity was not recovered by the decrease of the influent phosphorus concentration from 7.5 mg/L to 0.9 mg/L. The nitrogen removal increased by the decrease of influent phosphorus concentration both in SBR and SBBRs.

Effect of Operating Variables for Phosphate Removal with Cuttlefish Processing Sludge (오징어가공 슬러지를 이용한 인산염인 제거 공정에 미치는 영향인자)

  • 최봉종;이승목;김근한
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.87-91
    • /
    • 1998
  • The removal effect of phosphate by sludge from wastewaters prior to discharge into natural waters is an essential measure to prevent eutrophication in receiving waters. There is need for developing low cost, easily and abundantly available, efficient adsorbents for the removal of phosphorus (P as orthophosphate) during the tertiary treatment of wastewaters. The adsorbent carbon which is prepared with fisheries wastes on a laboratory scale has been used to evaluate its performance for phosphate adsorption. Phosphate removal increase with increasing adsorbent dose and temperature, but shows no changes at an adsorbent dose over 8 g/l.

  • PDF

Catalistic effect of sludge on $NO_x$ removal in cylinder type reactor (원통형 플라즈마 반응기에서 $NO_x$ 제거에 미치는 슬러지의 촉매효과)

  • Park, Jae-Yoon;Lee, Kyung-Ho;Park, Sang-Hyun;Kim, Hyung-Man;Kim, Jong-Suk;Ha, Hyun-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1777-1779
    • /
    • 2001
  • In this experiment, an attempt to use the sludge pellets as catalyst for NO removal from simulated gas is experimentally investigated by using cylinder type reactor. An experimental investigation has been conducted for NO concentration of 50[ppm], 100[ppm], 200[ppm] balanced with air. a gas flow rate of 5[1/min]. Cylinder type reactor is at upstream of system for corona discharge and packed bed type reactor filled with sludge pellets ate put at downstream of Cylinder type reactor for catalystic effect. And AC voltage to discharge the gases was supplied. In the result, NO removal with magnetic field is higher than that without magnetic field, when packed-bed reactor with sludge pellet is installed at downstream of cylinder reactor NO, $NO_2$ removal rate increased and $O_3$ is not generated.

  • PDF

Removal of Rhodamine B in Water by Ultraviolet Radiation Combined with Electrolysis(I) (전기분해와 UV 조사에 의한 수중의 Rhodamine B의 제거(I))

  • Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.6
    • /
    • pp.439-445
    • /
    • 2008
  • The feasibility study for the application of the removal and mineralization of Rhodamine B (RhB) was performed in a batch electrochemical reactor. The electro/UV process was consisted of DSA (dimensionally stable anode) electrode and UV-C or ozone lamp. The experimental results showed that RhB removal by the ozone lamp was higher than that of the UV-C lamp. Optimum current of the electro/UV process was 1 A. The electrochemical, UV and electro/UV process could completely degrade RhB, while a prolonged treatment was necessary to reach a high level RhB mineralization. It was observed that RhB removal in electro/UV process is similar to the sum of the UV and electrolytic decolorization. However, it was found that the COD of RhB could be degraded more efficiently by the electro/UV process (90.2 %) than the sum of the two individual oxidation processes [UV (19.7%) and electrolytic process (50.8%)]. A synergetic effect was demonstrated between the UV and electrolysis.

Post Sliced Cleaning of Silicon Wafers using Ozone and Ultrasound (오존과 초음파를 이용한 실리콘 웨이퍼의 Post Sliced Cleaning)

  • Choi, Eun-Suck;Bae, So-Ik
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.75-79
    • /
    • 2006
  • The effect of ozone and/or ultrasound treatments on the efficiency of slurry removal in post sliced cleaning (PSC) of silicon ingot was studied. Efficiency of slurry removal was evaluated as functions of time, temperature and surfactant with DOE (Design of Experiment) method. Residual slurries were observed on the wafer surface in case of cleaning by ozone or ultrasound separately. However, a clean wafer surface was appeared when cleaned with ozone and ultrasound simultaneously. It has found that cleaning time was the main effect among temperature, time and surfactant. Elevated temperature, addition of surfactant and high ozone concentration helped to accelerate efficient removal of slurry. The improvement of removal efficiency seems to be related to the formation of more active OH radicals. The highly cleaned surface was achieved at 10 wt% ozone, 1 min and 10 vol% surfactant with ultrasound. Application of ozone and ultrasound might be a useful method for PSC process in wafer cleaning.

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration- (선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리-)

  • 김인수;김억조;김동근;고성정;안종수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF