• 제목/요약/키워드: removal effect

검색결과 3,171건 처리시간 0.03초

버어리종 담배의 염소에 관한 연구 VI. 폴리에칠렌 피복필림 제거시기가 토양과 잎담배의 염소함량에 미치는 영향 (STUDIES ON THE CHLORINE OF BURLEY TOBACCO PLANTS VI. THE EFFECT OF REMOVAL TIME OF MULCHED POLYETHYLENE FILM ON THE CHLORINE CONTENTS OF SOIL AND TOBACCO LEAVES)

  • 김상범;배길관
    • 한국연초학회지
    • /
    • 제11권1호
    • /
    • pp.19-25
    • /
    • 1989
  • Effect of removal time of mulched polyethylene film on the chlorine content of toP soil and on the chlorine absorption by burley tobacco Plants was investigated under the field condition in 1986 and 1987. Treatment consisted of 4 removal times (from 30 to 75 days after transplanting with IS days interval) and control (no removal). The chlorine content of top Boll at 15 days after removal of mulched polyethylene film(MPF) lowered temporarily, and the decrement of chlorine content of top soil was closely related to the sum of rainfalls after removal of MPF. The chlorine was accumulated much in upper leaves when the MPF being removed early, while the chlorine was accumulated much in lower loaves when the MPF being removed late, relatively. However, the removal of MPF had no effect on the chlorine content of whole leaf. The yield decreased with removal of MPF during growing period.

  • PDF

전기투석을 이용한 구리이온의 제거 시 운전인자의 영향 (Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis)

  • 정효상;이강춘
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

뽕잎차에 의한 음용수중 Cd과 Pb의 제거효과 (Effect of Mulberry Leaf Tea for the Removal on Cd and Pb in drinking water)

  • 김현복;이완주
    • 한국잠사곤충학회지
    • /
    • 제40권1호
    • /
    • pp.17-22
    • /
    • 1998
  • To investigate the detoxificative effect of tea, five kinds of tea(mulberry, anaerobic treated mulberry, green, barly tea and corm tea) were selected and determined their dotoxication activities for Cd and Pb in drinking water. The effect of tea on the removal of Cd and Pb were increased proportionally to the contents of teas. Anaerobic treated mulberry leaf tea showed stronger detoxication activity than the others. In drinking water contaminated with Cd, the removal effect of Cd was high 27% by anaerobic treated mulberry leaf tea and 14% by mulberry leaf tea as compared to green tea. Also, in drinking water with Pb, the removal effect of anaerobic treated mulberry leaf tea was the best among five kinds of tea. Pretreatment method on the removal effect of Cd was better than post-treatment method in the treatment method.

  • PDF

A critical review of fluoride removal from water by using different types of adsorbents

  • Prashant S. Lingayat;Rampravesh K. Rai
    • Advances in environmental research
    • /
    • 제12권2호
    • /
    • pp.77-93
    • /
    • 2023
  • The water can be contaminated by natural sources or by industrial effluents. One such contaminant is fluoride. Fluoride contamination in the water environment due to natural and artificial activities has been recognized as one of the major problems worldwide. Among the commonly used treatment technologies applied for fluoride removal, the adsorption technique has been explored widely and offers a highly efficient simple and low-cost process for fluoride removal from water. This review paper the recent developments in fluoride removal from surface water by adsorption methods. Studies on fluoride removal from aqueous solutions using various carbon materials are reviewed. Various adsorbents with high fluoride removal capacity have been developed, however, there is still an urgent need to transfer the removal process to an industrial scale. Regeneration studies need to be performed to more extent to recover the adsorbent in field conditions, enhancing the economic feasibility of the process. Based on the review, technical strategies of the adsorption method including the Nano-surface effect, structural memory effect, anti-competitive adsorption and ionic sieve effect can be proposed. The design of adsorbents through these strategies can greatly improve the removal efficiency of fluoride in water and guide the development of new efficient methods for fluoride removal in the future. This paper describes brief discussions on various low-cost adsorbents used for the effective removal of fluoride from water.

혐기조-간헐포기조-개량조로 구성된 영양소 제거 공정에서 온도의 영향 (Temperature Effect on the Nutrient Removal in the Combined Biological Nutrient Removal System (CBNR) with Anaerobic-Intermittent Aerobic-Modified Oxic Reactors)

  • 강영희;한기봉
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.639-647
    • /
    • 2006
  • The temperature effect at $20^{\circ}$ and $10^{\circ}$ on the nutrient removal efficiency was evaluated in the combined biological nutrient removal system (CBNR) with anaerobic-intermittent aerobic-oxic reactors. The test was conducted under the conditions of various ratios of intermittent aeration time and distribution of influent raw water to CBNR. The removal efficiencies of organics, nitrogen and phosphorus were a little bit better at $20^{\circ}$ than at $10^{\circ}$. However the large difference of temperature effect on the nutrient removal efficiency between $20^{\circ}$ and $10^{\circ}$ was not appeared because of highly sustained MLSS concentrations in the reactors and controlled intermittent aeration time. In the removal of phosphorus, Mode III (50/70 min in aeration on/off time, 3 times of intermittent aeration) showed more effective compared with short aeration time of Mode IV. In case of N, P removal, the denitrification rate was lower in Mode A with splitted inflow into anaerobic and intermittent aeration basins than in Mode B with sole inflow into anaerobic basin.

Parametric study for enhanced performance of Cu and Ni electrowinning

  • Kim, Joohyun;Kim, Han S.;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.201-206
    • /
    • 2019
  • In this study, we performed an electrowinning process for effective removal of metals (Cu and Ni) in solution and their recovery as solid forms. A complete removal of Cu and Ni (1,000 mg/L) was observed during four times recycling test, indicating that our electrowinning system can ensure the efficient metal removal with high stability and durability. In addition, we investigated effect of operation parameters (i.e., concentration of boric acid only for Ni, variation of pH, concentration of electrolyte ($H_2SO_4$), and cell voltage) on the efficiency of metal removal (Cu and Ni) during the electrowinning. The addition of boric acid significantly enhanced removal efficiency of Ni as the concentration of boric acid increased up to 10 g/L. Compared to negligible pH effect (pH 1, 2, and 4) on the Cu removal, we observed the increase in removal efficiency of Ni as the pH increased from 1 to 4. The electrolyte concentration did not significantly influence the removal of Cu and Ni in this study. We also obtained great removal rates of Cu and Ni at 2.5 V and 4.0 V, which were much faster than those at lower voltages. Finally, almost 99% of each Cu and Ni (1,000 mg/L) was selectively removed from the mixture of metals by adjusting pH and addition of boric acid after the completion of Cu removal. The findings in this study can provide a fundamental knowledge about effect of important parameters on the efficiency of metal recovery during the electrowinning.

농어촌의 수질오염과 수질특성에 적합한 정수 처리시스템의 개발에 관한 연구(1) (A Survey of water pollution and the development of water treatment system on agricultural Area)

  • 정문호;김영규;조태석;배현주;신명옥;김수연;김민지;김민영;김수복
    • 환경위생공학
    • /
    • 제12권2호
    • /
    • pp.65-74
    • /
    • 1997
  • The purpose of this study was to investigate the removal effect and variation of contaminated water by various water treatment processes using sediment filter, activated carbon, photocatalysis, reverse osmosis, ultra violet sterilizer and ultra filtration. The removal effect of chloride and trace metal was low by activated carbon and ultra filter but high in reverse osmosis. The removal effect of bacteria and E. coli was low by activated carbon and membrane filter system using activated carbon but high in impregnated activated carbon. The removal effect of TCE was low in sand and ultra filter system as compared with activated carbon. Ultra filtration process was effective for purify agricultural water without E.coli. Reverse osmosis was effective to remove heavy metal and activated carbon was effective to remove halogenated organic chemical compound. The flux and the removal effect of COD in spiral wound ultrafilter were higher than the hollow fiber ultrafilter.

  • PDF

금속파티클-AI2O3Barrier 반응기의 NOx 제거에 미치는 유전체 영향 (Effect of Dielectrics on NOx Removal of Metal Particle-AI2O3 Barrier Reactor)

  • 박재윤;김종석;고희석;김형만;배명환
    • 한국전기전자재료학회논문지
    • /
    • 제16권3호
    • /
    • pp.247-252
    • /
    • 2003
  • In this paper, we made four types of metal particle $Al_2$O$_3$ barrier reactors with and without dielectric of BaTiO$_3$ between metal particle and $Al_2$O$_3$ barrier to investigate NOx removal characteristic and the effect of dielectric on Nox removal. And Nox removal rate is measured when sludge pellets are put at down stream of plasma reactor. Nox removal rate in the reactor with $Al_2$O$_3$ barrier is much better than that in the reactor without $Al_2$O$_3$ barrier, Nox removal rate is not so good in metal particle-Al$_2$O$_3$ barrier reactor with BaTiO$_3$ between metal particle and $Al_2$O$_3$ barrier, however, Nox removal rate is about 40% in metal particle-Al$_2$O$_3$ barrier reactor with TiO$_2$. The most of NO is conversed to NO$_2$ in these kind of reactor. When sludge pellets are put at down stream of plasma reactor, Nox removal rate is greatly improved up to 90%. It indicates that sludge pellets have great effect on the NO$_2$ removal and the improvement of Nox removal rate, however, dielectric materials between metal particle and $Al_2$O$_3$ barrier have not effect. Organic materials included in sludge may react with NO$_2$ and ozone so that Nox removal rate is greatly improved.

가수분해 산물 분포를 이용한 급속혼화강도가 화학적 인 제거 효율에 미치는 영향의 규명 (Evaluation of effect of rapid mixing intensity on chemical phosphorus removal using Al hydrolysis speciation)

  • 김승현;윤동수;문병현
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.367-373
    • /
    • 2011
  • Mechanism of rapid mixing effect on chemical phosphorus removal is evaluated in this study. Assuming that chemical phosphorus removal is unaffected by mixing time, only rapid mixing intensity is evaluated. In order to find out the mechanism, it is hypothesized that rapid mixing affects the Al hydrolysis speciation, and that formation of more monomeric species ($Al^a$) results in better removal of phosphorus. According to a ferron assay, more $Al^a$ formed at higher mixing intensity than at lower intensity. Subsequent experiments revealed that better phosphorus removal was obtained at higher intensity than at lower intensity, in terms of the molar ratio of $Al_{added}/P_{removed}$. The proposed hypothesis was proved in this study. Chemical phosphorus removal is affected by rapid mixing intensity due to its effect on the Al hydrolysis speciation.

Effect of Operational Parameters on the Removal of Microcystis aeruginosa in Electro-flotation Process

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • 한국환경과학회지
    • /
    • 제25권10호
    • /
    • pp.1417-1426
    • /
    • 2016
  • Despite the low removal efficiencies reported by previous studies, electro-flotation still stands out among other microalgae removal methods for its economical and environmental benefits. To enhance removal efficiency, the important factors that limit the performance of this method must be investigated. In this study, the possible ways of increasing the removal efficiency of microalgae have been explored by investigating the effects of several important variables in electro-flotation. Eight parameters, namely flotation time, rising time, current density, pH, conductivity, electrode distance, temperature and initial concentration were evaluated using a one-parameter-at-a-time approach. Results revealed that the operational parameters that greatly affected the removal efficiency of microalgae were electro-flotation time, current density, pH, and initial concentration. The effect of conductivity, electrode distance, and temperature on removal efficiency were insignificant. However, they exhibited positive an indirect positive effect on power demand, which is nowadays considered an equally important aspect in the running of a feasible and economically efficient electro-flotation process.