• Title/Summary/Keyword: removal capacity

Search Result 1,113, Processing Time 0.022 seconds

Passive Heat Removal Characteristics of SMART

  • Seo, Jae-Kwang;Kang, Hyung-Seok;Yoon, Joo-Hyun;Kim, Hwan-Yeol;Cho, Bong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.623-628
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt thermal capacity named SMART (System-Integrated Modular Advanced Reactor) is currently under development in Korea Atomic Energy Research Institute (KAERI) for multi-purpose applications. Modular once-through steam generator (SG) and self-pressurizing pressurizer equipped with wet thermal insulator and cooler are essential components of the SMART. The SMART Provides safety systems such as Passive Residual Heat Removal System (PRHRS). In this study, a computer code for performance analysis of the PRHRS is developed by modeling relevant components and systems of the SMART. Using this computer code, a performance analysis of the PRHRS is performed in order to check whether the passive cooling concept using the PRHRS is feasible. The results of the analysis show that PRHRDS of the SMART has excellent passive heat removal characteristics.

  • PDF

Low concentration cadmium removal using weathered sand of basalt

  • Park, Jae Hong;Lee, Jae Kwan;Shin, Dong Seok
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.51-58
    • /
    • 2021
  • The natural weathered sand of basalt (WSB) has been used for the removal of cadmium from aqueous solution. The influence of various parameters i.e., contact time, pH, weathered sand of basalt dosage, particle size of the weathered sand of basalt, temperature and initial cadmium concentration were analyzed. Cadmium adsorption kinetics was well described by the pseudo second order model. Adsorption equilibrium for cadmium was properly well fitted to Langmuir isotherm model with maximum adsorption capacity 0.50 mg/g. Compared with the other experimental results using various kinds of adsorbents at a low concentration (1.0 mg/L or so) similar to that of this study, the cadmium removal efficiency using weathered sand of basalt was higher. It has been demonstrated that weathered sand of basalt has a available alternative adsorbent for cadmium when its initial concentration is low.

Performance of Rotating Biological Contactor (RBC) under Different Hydraulic Loading Rates and Rotational Speeds on Ammonia Removal in a Recirculating System

  • Son Maeng Hyun;Jeon Im Gi;Jo Jae-Yoon;Moon HaeYoung
    • Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.52-57
    • /
    • 1999
  • Air-drived rotating biological contactor (RBC) system, which is effective method in filtering performance, was tested for the nitrification capacity in a recirculating system. At ammonia concentrations between 0.029 and 0.528 mg/l, the effect of ammonia loading rate on ammonia removal rate at three different hydraulic loading rates could be defined by the following first­order regression models: Hydraulic loading rate of $14.8 m^3/m^3/day:\;y=39.2\times+3.4 (r^2=0.9137)$, Hydraulic loading rate of $26.5 m^3/m^3/day: y=53.3\times+4.0 (r^2=0.8686)$, Hydraulic loading rate of $37.3 m^3/m^3/day: y=58.4\times+4.2 (r^2=0.7755)$, where, $\times$ is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3/day)$, The equations showed the optimal ammonia removal rate at the hydraulic loading rate of $26.5m^3/m^3/day$. Below the ammonia concentration of 2.72 mg/l, first-order regression models between ammonia loading rate and ammonia removal rate at three different rates of speed are defined as follows: Rotational speed of $0.75 rpm: y=28.5\times+4.7 (r^2=0.9143)$, Rotational speed of $1.0 rpm: y=33.6\times+8.4 (r^2=0.9534)$, Rotational speed of $2.0 rpm: y=28.9\times+3.6 (r^2=0.9488)$, where, x is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3day)$. The equations show the ammonia removal rate at the rotational speed of 1.0 rpm is significantly higher than that at the rotational speed of either 0.75 rpm or 2.0 rpm (P<0.05).

  • PDF

Feasibility of Industrial by-products as a Seed Crystal of Struvite Crystallization for the Removal of Highly Concentrated Nitrogen and Phosphorus (고농도의 질소와 인제거를 위한 Struvite 정석반응의 정석재로서 산업부산물의 이용 가능성)

  • Yim, Soo-Bin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.664-672
    • /
    • 2010
  • This study was performed to evaluate the feasibility of industrial by-products such as converter slag, olivine, red mud and fly ash as a seed crystal of struvite crystallization for the removal of highly concentrated $NH_4-N$ and $PO_4-P$. In the kinetic experiments, more than 90% of $NH_4-N$ and $PO_4-P$ was eliminated by struvite crystallization within 30 minutes of reaction time. The pH range in meta-stable region of struvite crystallization was found to be pH 7.0~9.0 under the Mg:N:P=1:1:1 equi-molar condition with 100 mg/L of $NH_4-N$. Total removal efficiencies of $NH_4-N$ and $PO_4-P$ by both struvite precipitation and crystallization were increased with the increase of pH. Removal efficiencies of $NH_4-N$ and $PO_4-P$ were significantly enhanced by struvite crystallization using industrial by-products as a seed crystal compared with those by struvite precipitation without seed crystal. Red mud, converter slag, olivine and fly ash enhanced the removal efficiencies of $NH_4-N$ by 40.9%, 37.7%, 28.4% and 16.4%, respectively. Removal efficiencies of $PO_4-P$ for converter slag, red mud, fly ash, olivine were increased by 3.7 times, 2.6 times, 72.4% and 68.0%, respectively. Converter slag and red mud showed higher feasibility as a seed crystal than others for the removal of highly concentrated $NH_4-N$ and $PO_4-P$. In particular, converter slag might have a high capacity of phosphorus removal.

Comparison of the $SO_2$ Removal Efficiency by Mixing Enhancement Shape (혼합 촉진 장치의 형상에 따른 탈황효율 비교)

  • Chung, Jin-Do;Kim, Jang-Woo;Bae, Young-Peel
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.17-22
    • /
    • 2010
  • The aim of this study is to research applicable possibility of DSI (Dry Sorbent Injection) technique in $SO_2$ removal process using lab-scale facility based on 500MW in capacity coal-fired thermal power plant operated by South Korea N. Power Co., Ltd. To increase the $SO_2$ removal efficiency, it is considered the mixing enhancement as different shapes called lobed-plate and stepplate tested ultimately for optimum shape. Also it tested to analysis $SO_2$ removal efficiency by numbers of injection holes. At experimental it showed the $SO_2$ removal efficiency is higher using mixing enhancement than not installed mixing enhancement and case on the step-plate was shown the most $SO_2$ removal efficiency. Also, $SO_2$ removal efficiency was higher recording which will increase the injection holes case on not installed mixing enhancement. But, the $SO_2$ removal efficiency was higher 4 injection holes case on installed mixing enhancement.

Comparison on Chlorine Removal Characteristics of Chlorella vulgaris and Green Tea in Aqueous Solution (수용액상에서 클로렐라와 녹차의 염소 제거 효과 비교)

  • 인만진;조인경;김선희;김동청;채희정;오남순;김동호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.2
    • /
    • pp.344-349
    • /
    • 2001
  • The removal of chlorine from aqueous solutions on dried Chlorella vulgaris(DCV) and green tea powder(GTP) were investigated as a function of contact time, pH and initial chlorine concentration. Removal by DCV and GTP reached equilibrium after 3hrs and 0.5hr, respectively. Optimum removal pH values of DCV and GTP were determined as above 10. Both Langmuir and Freundlich adsorption models were suitable for describing the short-term removal of chlorine by DCV and GTP. According to Langmuir adsorption isotherms the maximum removal capacity of DCV (2.75mg $Cl_2/mg$) was nearly two times greater than those of GTP (1.53mg $Cl_2/mg$) and activated carbon (1.47mg $Cl_2/mg$). These results suggested that Chlorella vulgaris biomass might potentially be used as an alternative to traditional water treatment materials for removal of residual chlorine in drinking water or process waste-water.

  • PDF

Fundamental Study on Adsorption Capacity and Utilization of Coal Waste as Adsorbents (석탄폐석의 흡착능 및 흡착제로의 활용방안에 관한 기초 연구)

  • 한동준;임재명;이찬기;이해승
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.61-72
    • /
    • 1997
  • This research aims to remove the heavy metals, nonbiodegradable COD(NBDCOD), and color using the coal waste. The experimental by heat treatment was performed to advance the adsorption capacity. The results are as follows ; i) The coal waste had the adsorption capacity of heavy metals and the rates were in the range of 20 to 30 percents. ii) The heat treatment was the optimum condition that the reaction time was 6 hours at $500^{\circ}C$, , iii) In the column experimen, non-treated coal waste removed the COD and color in the range of 20 to 60 percents. iv) Heat-treated coal waste showed higher removal rate of the color in biological effluent, and heavy metal and COD removal rates were changed by the filteration rates.

  • PDF

Chemical Treatment of Low-level Radioactive Liquid Wastes(II) (The Determination of Cation Exchange Capacity on various Clay Minerals)

  • Lee, Sang-Hoon;Sung, Nak-Jun
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.75-81
    • /
    • 1977
  • This experiment has been carried out to determine the pH dependent cation exchange capacity concerning the sorption phenomenon of long-lived radionuclides contained in low-level liquid radioactive waste on various clay minerals. The pH dependent cation exchange capacity determined by Sawhney's method are used to the analysis of sorption phenomenon. About 70 percent of the total cation exchange capacity is contributed by the pH dependent CEC due to the negative charge originated naturally in clays in case of clinoptilolite, vermiculite and sodalite. It is sugested in this test that the high neutral salt CEC, that is, highly charged clays would show good fixation yield. The removal of radionuclides at the pH range more than pH 9 is considered the hydroxide precipitation of metal ion rather than the cation exchange. The Na-clay prepared by the method of successive isomorphic substitution with electrolyte showed a considerable improvement in removal efficiency for the decontamination.

  • PDF

Engineering Analysis of Biofilter (바이오필터의 공학적 해석)

  • 김인호;최호석
    • KSBB Journal
    • /
    • v.17 no.2
    • /
    • pp.115-120
    • /
    • 2002
  • Biofiltration is a bioprocess treating volatile organic compounds (VOCs) in order to convert the VOCs to harmless products. This review on biofiltration is intended to provide an engineering concept such as removal efficiency, maximum load, elimination capacity and so on. Besides, modeling concept of biofilter is also supplied for designing biofilter system. Quantitative data generated in our research group is shown to explain the engineering concept as well as the modeling idea.

A Study on the Removal of Pollutants from Wastewater by Aquatic Macrophytes (수생식물에 의한 폐수의 오염물질제거에 관한 연구)

  • Cho, Hae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.941-946
    • /
    • 2012
  • Macrophyte plays an important role in purification of wastewater. They have capacity to improve the water quality by absorbing nutrients, with their effective root system. In this study, removal of nutrient as well as organic matter was observed by some important macrophytes i.e. Pistia stratoites, Hydrocharis dubia and Salvinia sp. indepe ndently as well as in mixed culture under the laboratory condition. The highest total nitrogen removal was observed for Pistia stratoites (86.47%) in monoculture and Salvinia sp. + P. stratoites (76.11%) in mixed culture system. Corresponding figures for total phosphorous were observed for P. stratoites (75.60%) in monoculture and Salvinia sp. + P. stratoites (71.11%) in mixed culture system. Similar result was observed for ammonia removal in both systems. Additionally, P. stratoites showed the highest removal of organic matter, in monoculture system (68.46%) where as Salvinia sp. + P. stratoites showed the highest removal of organic matter in mixed culture system (82.73 %).