• Title/Summary/Keyword: reliabilities

Search Result 339, Processing Time 0.023 seconds

Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke (뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구)

  • Park, Il-Woo;Lim, One-Bin;Park, Kyue-Nam;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

Reliability of the Visual Discrimination Scale on Oral Mucosa Pressure Ulcer for Healthcare Providers (의료인을 위한 구강점막욕창 시각적 감별도구의 신뢰도)

  • Uhm, Ju-Yeon;Kim, Myoung Soo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.443-450
    • /
    • 2020
  • The purpose of this study was to examine the inter-rater and intra-rater reliability of the oral mucosa pressure ulcer classification system based on the photographs. The study consisted of two stages; development and evaluation. In the developmental stage, 9 photographs of 82 were selected. In the evaluation stage, a total of 49 participants were invited web-based survey by e-mail. Cohen's weighted kappa and Krippendorff's alpha were used to define the inter-rater reliability. Nine photographs consisted of two, three, three, and one in normal, stage 1, stage 2, and stomatitis, respectively. The inter-rater reliabilities of wound care nurse specialist, intensive care nurse specialist, and dentist groups were 0.75, 0.70, and 0.78, respectively. The intra-rater reliability was 0.73. The inter-rater and intra-rater reliabilities of the oral mucosa pressure ulcer classification system showed substantially good agreement.

Analysis for Influence and Geometry of GPS/Galileo System (GPS/Galileo 시스템의 기하구조 및 영향 분석)

  • Lee Jae-One
    • Journal of Navigation and Port Research
    • /
    • v.29 no.8 s.104
    • /
    • pp.763-770
    • /
    • 2005
  • Global Navigation Satellite System (GNSS) has become an indispensable tool for providing precise position, velocity and time information for many applications like traditional surveying and navigation etc. However, Global Positioning System (GPS), which was developed and is maintained and operated by the U.S. Department of Defence (DoD), has monopolized the world industry and market, and hence there exists the situation that most of GNSS users absolutely depend upon the GPS. In order to overcome the monopoly, some countries, such as Russia, Japan and European Union (EU), have developed their own GNSSs, so-called GLONASS, JRANS and Galileo systems. Among them, the most prospective system in near future is EU's Galileo system scheduled to launch in 2008. This research has focused on the next generation GNSS system based on GPS and Gralileo system with developing a GNSS simulation software, named as GIMS2005, which generates and analyzes satellite constellation and measurements. Based on the software, a variety of simulation tests have been carried out to recognize limits of GPS-only system and potential benefits of integrated GPS/Galileo positioning. Geometry simulation results have showed that comparing with GPS-only case, the number qf visual satellites, Dilution of Precision (DOP) values, internal reliabilities and external reliabilities.

Determination of the Optimal Contract Amount of the Hydropower Energy Considering the Reliabilities of Reservoir Inflows (저수지(貯水池) 유입량(流入量)의 신뢰도(信賴度)를 고려한 최적(最適) 계약전력량(契約電力量)의 결정(決定))

  • Kwon, Oh Hun;Yoo, Ju Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.141-149
    • /
    • 1993
  • Production of hydro-energy is random in its output amount due to the characteristics of the reservoir inflows. Therefore, it is necessary to provide the rationality in determining the amount of energy for a supply contract. This study presents a methodology for determining reasonably reliable amount of the energy supply considering the energy sale-incomes associated with the penalties which are subject to inflow-reliabilities. The objective function consists of the returns of energy sales and the risk-loss function to reflect statistically relevant risks. A range of the coefficient of the risk-loss function was figured out by its sensitivity analysis. The risk-loss herein means the penalty which should be paid by the energy supplier in case that the level of the energy supply is behind the contracted amount. And the reliability of reservoir inflow is defined by the exceedance probability of the inflow. The log-normal distribution was accepted as the probability density function of monthly inflows on the level of significance at 5%. Golden-ratio searching was applied to identify the optimal reliability and Incremental Dynamic Programming was used to maximize generation of the hydro-power energy in reservoir operation. The algorithm was the applied to the Daechung multi-purpose reservoir and hydro-power plant system in order to verify its usefulness.

  • PDF

Reliability-based Design Criteria for Reinforced Concrete Structures Based on Partial and Combined Resistance Factor Formats (부분(部分) 및 조합저항계수형식(組合抵抗係數形式)에 의한 철근(鐵筋)콘크리트구조(構造)의 신뢰성(信賴性) 계기준(計基準))

  • Oh, Byung Hwan;Lee, Seong Lo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.87-97
    • /
    • 1990
  • There is the need to balance safety, economy and serviceability in all phases of society problems. This is especially true in structural code formulation. where a framework is established by which practicing structural engineers can be assured of designing structures that reasonably meet the above three objectives. The existing design codes, which are generally based on the structural theory and certain engineering experience, do not realistically consider the uncertainties of loads and resistances and the basic reliability concepts. The purpose of the present study is therefore to develop the realistic reliability-based design criteria to secure adequate safety arid reliability, and to derive the models for partial and combined resistance factor formats. To this end, the reliability levels of our existing design code for concrete structures are first evaluated and the target reliabilities are determined, the new code formats are evolved from these target reliabilities. The present study indicates that the proposed formats exhibit relatively-uniform reliability and reasonably take into account the different material characteristics of concrete and steel in concrete structures.

  • PDF

Reliability of Three Methods for Measuring Length of Iliotibial Tract (엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.

Thermal Cycling and High Temperature Storage Reliabilities of the Flip Chip Joints Processed Using Cu Pillar Bumps (Cu Pillar 플립칩 접속부의 열 싸이클링 및 고온유지 신뢰성)

  • Kim, M.Y.;Lim, S.K.;Oh, T.S.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • For the flip chip joints processed using Cu pillar bumps and Sn pads, thermal cycling and high temperature storage reliabilities were examined as a function of the Sn pad height. With increasing the height of the Sn pad, which composed of the flip chip joint, from 5 ${\mu}m$ to 30 ${\mu}m$, the contact resistance of the flip chip joint decreased from 31.7 $m{\Omega}$ to 13.8 $m{\Omega}$. Even after thermal cycles of 1000 times ranging from $-45^{\circ}C$ to $125^{\circ}C$, the Cu pillar flip chip joints exhibited the contact resistance increment below 12% and the shear failure forces similar to those before the thermal cycling test. The contact resistance increment of the Cu pillar flip chip joints was maintained below 20% after 1000 hours storage at $125^{\circ}C$.

Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images (디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교)

  • Sung, Il-Hoon;Kim, Ki Chun;Sung, Chang-Ho;Seo, Woo-Young;Lee, Doo-Yeon;Cho, Young A
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensors Using 2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium brornide (2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide를 이용한 고분자 습도센서의 감습 특성 및 신뢰성)

  • Lee, Chil-Won;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.461-466
    • /
    • 1999
  • The humidity sensor containing ammonium salt was prepared from the copolymer of 2-methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide (MDHAB)/MMA/DAEMA = 6/3/1. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $298k{\Omega},\;11k{\Omega}$, and $2.3k{\Omega}$ at 40%RH, 70%RH and 90%RH, respectively, at $5^{\circ}C$ and the humidity-sensitive characteristics were suitable for low temperature humidity sensor. The temperature-dependent coefficient between $5^{\circ}C$ and $20^{\circ}C$ was found to be $-0.80%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 38 sec for the relative humidity ranging from 34%RH to 88%RH at $20^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a humidity sensor.

  • PDF

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensor Containing Phosphonium Salts (포스포늄 염을 가진 고분자 습도센서의 감습 특성 및 신뢰성)

  • Kim, Ohyoung;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.554-560
    • /
    • 1998
  • Vinylbenzyl triphenyl phosphonium chloride(VTPC)/styrenes=3.7 copolymer was prepared for the moisture-absorptive polyelectrolyte dew sensor containing phosphonium salts. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $11M{\Omega}$, $980k{\Omega}$, $50k{\Omega}$, and $11k{\Omega}$ at 70%RH, 80%RH, 90%RH and 95%RH, respectively, at $25^{\circ}C$ and the humidity-sensitive charactristic was suitable for the dew sensor. The temperature-dependent coefficient between $15^{\circ}C$ and $35^{\circ}C$ was found to be $-0.25%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 45 sec for the relative humidity ranging from 70%RH to 98%RH at $25^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a dew sensor.

  • PDF