• Title/Summary/Keyword: relative-size

Search Result 2,118, Processing Time 0.03 seconds

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Topic Continuity in Korea Narrative (한국 설화문에서의 화제표현의 연속성)

  • Hi-JaChong
    • Korean Journal of Cognitive Science
    • /
    • v.2 no.2
    • /
    • pp.405-428
    • /
    • 1990
  • Language has a social function to communicate information. Linguists have gradually paid their attention to the function of language since the nineteen sixties, especially to the relationship of form, meaning and the function. The relationship could be more clearly grasped through disciyrse-based analysis than through sentence-based analysis. Many researches were centered on the discourse functional notion of topic. In the early 1970's the subject was defined as the grammatiocalized topic the topic as a discrete single constituent of the clause. In the late 1970's several lingusts including Givon suggerted that the topic was not an atomic, disctete entity, and that the clause could have more than one topic. The purpose of the present study is, following Givon, to study grammatical coding devices of topic and to measure the relative topic continuity/discontinuity of participant argu, ents in Korean narratives. By so doing, I would like to shed some light on effective ways of communicating information. The grammatical coding devices analyzed are the following eight structures: zero-anaphora, personal pronous, demonstrative pronouns, names, noun phrases following demonstratives, noun phrases following possessives, definite noun phrases and indefinite referentials. The narrative studied for the count was taken from the KoreanCIA chief's Testiomny:Revolution and Idol by Hyung Wook Kim. It was chosen because it was assumed that Kim's purpose in the novel was to tell a true story, which would not distort the natural use of language for literary effect. The measures taken in the analysis wre those of 'lookback', 'persistence', ambiguity'. The first of these, 'lookback', is a measure of the size of gap between the previous occurrence of a referent and its current occurence in the clause. The meausure of persistence, which is a measure of the speaker's topocal intent, reflects the topic's importance in the discourse. The third measure is a measure of ambiguity. This is necessary for assessing the disruptive effects that other topics within five previous clauses may have on topic identification. The more other topics are present within five previous clauses, the more difficult is the task of correct identification of a topic. The results of the present study show that the humanness of entities is the most powerful factior in topic continutiy in narrative discourse. The semantic roles of human arguments in narrative discourse tend to be agents or experiences. Since agents and experiences have high topicality in discourse, human entities clearly become clausal or discoursal topics. The results also show that the grammatical devices signal varying degrees of topic continuity discontinuity in continuous discourse. The more continuous a topic argument is, the less it is coded. For example, personal pronouns have the most continutiy and indefinite referentials have the least continutiy. The study strongly shows that topic continuity discontinutiy is controlled not only by grammatical devices available in the language but by socio-cultural factors and writer's intentions.

Experimental Studies on Uterine Catecholamines (Catecholamines에 관(關)하여 -제5편(第五編) : 자궁(子宮) catecholamines에 관한 실험적(實驗的) 연구(硏究)-)

  • Lee, Woo-Choo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.1
    • /
    • pp.37-60
    • /
    • 1983
  • The uterus receives adrenergic terminals from the mesenteric ganglia and considerably large amount of catecholamines have been shown to be contained in this organ. On the other hand, the activities of epinephrine, norepinephrine or adrenergic nerve on uterine motility is so complicated that many controversial results have been reporter. Recently, a large number of reports concerning the changes of uterine catecholamines content have appeared, but little is known about the role of uterine catecholamines in their activities on uterine motility. The present experiments were undertaken to determine the significance of the intrinsic uterine catecholamines in the physiology of uterus. Female albino rabbits weighing approximately 2 kg were employed in this experiment. uterine strip3 were prepared and suspended in a constant temperature $bath(38^{\circ}C)$ containing 100 ml of Locke's solution aerated with 95% oxygen and 5% carbon dioxide. Spontaneous motility was recorded on a smoked drum with an isotonic lever. The catecholamines concentration of the uterus was determined according to the Procedure described of Shore and Olin (1958). Human uterus obtained from patients was also used to determine the catecholam ines content of myometrium. Followings are summarized results. 1) On the non-pregnant rabbit uterine strips, epinephrine and norepinephrine significantly elevated the tonus and stimulated the spontaneous motility. Pretreatment with dichloroisoproterenol(DCI), an adrenergic beta-receptor blocker, enhanced the stimulatory activity of epinephrine or norepinephrine. On the other hand, pretreatment with dibenamine, an adrenergic alpha-receptor blocker, rendered the uterine muscle to exhibit inhibition after the administration of epinephrine or norepinephrine. Following the treatment with both DCI and dibenamine, epinephrine or norepinephrine produced no appreciable effects on the spontaneous motility of the uterus. These results suggest there exist both alpha and beta-adrenergic receptors in the uterine muscle and the response to epinephrine of the former is predominant over that of latter in the non-pregnant uterus of rabbits. The total catecholamines concentration of the non-pregnant uterus was $351\;m{\mu}g/g$ and the fractional concentrations of epinephrine and norepinephrine were $125\;m{\mu}g/g(35.7%)$ and $226\;m{\mu}g/g$ respectively. It is interesting to note that the catecholamines content of uterus was characterized by a high fractional corcentration of epinephrine relative to norepinephrine. 2) On the pregnant rabbit uterine strips, the effects of epinephrine and norepinephrine varied according to the period of pregnancy. The response to epinephrine of adrenergic beta receptor of uterus increased during pregnancy, and the effect of catecholamine was inhibitory in the early pregnancy but became stimulatory as the pregnancy progressed. This stimulating action on the uterine motility was found to occur through the action of norepinephrine. The uterine catecholamines concentration was markedly reduced during pregnancy. The catecholamines concentration was started to decrease in the early pregnancy, reached the lowest level in the mid-pregnancy and then started to increaae again in the late pregnancy when the total catecholamines content became the highest level of all. This increase of catefholamines in late pregnancy was chiefly due to the increase of norepinephrine. These results suggest that the uterine motility may be related to the catecholamines content, especially norepinephrine content in the uterus. 3) Bilateral oophorectomy of rabbits results in a marked shrink of the uterus in size. The spontaneous motility of the uterine segment of these animals was very weak and irregular. Norepinephrine produced inhibitory effect, whereas epinephrine was stimulatory or inhibitory effect on the uterine segment. The total catecholamines tontent in whole uterus was markedly reduced. The injection of estrogen into the oophorectornized rabbit increased the weight of uterus to approximately three times of that of oophorectornized animal. The apontaneous motility and the response to epinephrine and norepinephrine of the uterine segment were greatly enhanced. Both epinephrine and norepinephrine produced a marked stimulatory effects of the uterine motility. The uterine content of catecholamines, particularly epinephrine, was markedly increased. The injection of progesterone into the oophorectornized rabbit increaeed the weight of uterus to approximately 2.5 times of that of eophorectornized animal. The spontaneous motility of the uterine segment was weak and irregular. Epinephrine produced stimulatory effect at high concentrations but norepinephrine always prcdnced inhibitory effect on the uterine segment. The uterine content of catecholamines, particularly of norepinephrine, was markedly reduced. These results suggested that ovarian hormones play an important role not only on the growth and spontaneous norepinephrine of uterus but also on the catecholamines content and responee to epinephrine and norepinephrine of the uterus. 4) The intraperitoneal injection of reserpine(3 mg/kg) into the non-pregnant, pregnant and oophorectornieed rabbits markedly decreased the uterine content of catecholamines, particularly of the norepinephrine. The stimulatory response to epinephrine and. norepinephrine of the uterine segment of these reserpinized ratbits was markedly reduced whereas the inhibitory response to these catecholamines was enhanced. This finding further support the close relationship between the uterine catecholamines content and uterine response to epineptrire and norepinephrine. 5) In the human uterus, the concentration of epinephrine was actrally greater than that of norepinephrine and it was significantly greater during the proliferative phase of the menstrtal cycle. In the human pregnant uterus, the concentrations of toth epinephrine and ncrefinephrine were markedly reduced and showed about 45 percent rednction after 6-8 weeks of ectopic Pregnancy. At full term ana during labor, the concentrations of epinephrine and norepinephrine at placental sites were less than those found in the non-pregnant group. Of interest was the finding that the norepinephrine concentration of uterus from toxemic patients was two and half times higher than that of lower uterine segment of the nontoxemic pregnant individuals. Also the epinephrine concentraticn was slightly increaeed.

  • PDF

Sleep Duration and Cancer Risk: a Systematic Review and Meta-analysis of Prospective Studies

  • Zhao, Hao;Yin, Jie-Yun;Yang, Wan-Shui;Qin, Qin;Li, Ting-Ting;Shi, Yun;Deng, Qin;Wei, Sheng;Liu, Li;Wang, Xin;Nie, Shao-Fa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7509-7515
    • /
    • 2013
  • To assess the risk of cancers associated with sleep duration using meta-analysis of published cohort studies, we performed a comprehensive search using PubMed, Embase and Web of Science through October 2013. We combined hazard ratios (HRs) from individual studies using meta-analysis approaches. A random effect dose-response analysis was used to evaluate the relationship between sleep duration and cancer risk. Subgroup analyses and sensitivity analyses were also performed. Publication bias was evaluated using Funnel plots and Begg's test. A total of 13 cohorts from 12 studies were included in this meta-analysis, which included 723, 337 participants with 15, 156 reported cancer outcomes during a follow-up period ranging from 7.5 to 22 years. The pooled adjusted HRs were 1.06 (95% CI: 0.92, 1.23; P for heterogeneity =0.003) for short sleep duration, 0.91 (95% CI: 0.78, 1.07; P for heterogeneity <0.0001) for long sleep duration. In subgroup analyses stratified by cancer type, long duration of sleep showed an inverse relation with hormone-related cancer (HR=0.79; 95% CI: 0.65, 0.97; P for heterogeneity =0.009) and a greater risk of colorectal cancer (HR=1.29; 95% CI: 1.09, 1.52; P for heterogeneity =0.346). Further meta-analysis on dose-response relationships showed that the relative risks of cancer were 1.00 (95% CI: 0.99, 1.01; P for linear trend=0.9151) for one hour of sleep increment per day, and 1.00 (95% CI: 0.98, 1.01; P for linear trend=0.7749) for one hour of sleep increment per night. No significant dose-response relationship between sleep duration and cancer was found on non-linearity testing (P=0.5053). Our meta-analysis suggests a positive association between long sleep duration and colorectal cancer, and an inverse association with incidence of hormone related cancers like those in the breast. Studies with larger sample size, longer follow-up times, more cancer types and detailed measure of sleep duration are warranted to confirm these results.

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

Technical Efficiency in Korea: Interindustry Determinants and Dynamic Stability (기술적(技術的) 효율성(效率性)의 결정요인(決定要因)과 동태적(動態的) 변화(變化))

  • Yoo, Seong-min
    • KDI Journal of Economic Policy
    • /
    • v.12 no.4
    • /
    • pp.21-46
    • /
    • 1990
  • This paper, a sequel to Yoo and Lee (1990), attempts to investigate the interindustry determinants of technical efficiency in Korea's manufacturing industries, and also to conduct an exploratory analysis on the stability of technical efficiency over time. The hypotheses set forth in this paper are most found in the existing literature on technical efficiency. They are, however, revised and shed a new light upon, whenever possible, to accommodate any Korea-specific conditions. The set of regressors used in the cross-sectional analysis are chosen and the hypotheses are posed in such a way that our result can be made comparable to those of similar studies conducted for the U.S. and Japan by Caves and Barton (1990) and Uekusa and Torii (1987), respectively. It is interesting to observe a certain degree of similarity as well as differentiation between the cross-section evidence on Korea's manufacturing industries and that on the U.S. and Japanese industries. As for the similarities, we can find positive and significant effects on technical efficiency of relative size of production and the extent of specialization in production, and negative and significant effect of the variations in capital-labor ratio within industries. The curvature influence of concentration ratio on technical efficiency is also confirmed in the Korean case. There are differences, too. We cannot find any significant effects of capital vintage, R&D and foreign competition on technical efficiency, all of which were shown to be robust determinants of technical efficiency in the U.S. case. We note, however, that the variables measuring capital vintage effect, R&D and the degree of foreign competition in Korean markets are suspected to suffer from serious measurement errors incurred in data collection and/or conversion of industrial classification system into the KSIC (Korea Standard Industrial Classification) system. Thus, we are reluctant to accept the findings on the effects of these variables as definitive conclusions on Korea's industrial organization. Another finding that interests us is that the cross-industry evidence becomes consistently strong when we use the efficiency estimates based on gross output instead of value added, which provides us with an ex post empirical criterion to choose an output measure between the two in estimating the production frontier. We also conduct exploratory analyses on the stability of the estimates of technical efficiency in Korea's manufacturing industries. Though the method of testing stability employed in this paper is never a complete one, we cannot find strong evidence that our efficiency estimates are stable over time. The outcome is both surprising and disappointing. We can also show that the instability of technical efficiency over time is partly explained by the way we constructed our measures of technical efficiency. To the extent that our efficiency estimates depend on the shape of the empirical distribution of plants in the input-output space, any movements of the production frontier over time are not reflected in the estimates, and possibilities exist of associating a higher level of technical efficiency with a downward movement of the production frontier over time, and so on. Thus, we find that efficiency measures that take into account not only the distributional changes, but also the shifts of the production frontier over time, increase the extent of stability, and are more appropriate for use in a dynamic context. The remaining portion of the instability of technical efficiency over time is not explained satisfactorily in this paper, and future research should address this question.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF