• Title/Summary/Keyword: relative turbidity

Search Result 43, Processing Time 0.032 seconds

Evaluation of Stock Flocculation Phenomena Based on Turbidity Measurement (탁도 측정을 통한 지료의 응집거동 평가)

  • Lee, Ji-Young;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.4
    • /
    • pp.10-15
    • /
    • 2008
  • Flocculation phenomena of the stock mixed with cellulosic fibers, fillers and polymers were investigated by a new turbidity measurement system consisted of a probe-type turbidimeter, data acquisition system and computer. The probe-type turbidimeter allowed to measure the real time flocculation of the stock induced by single polymer and microparticle systems. Flocculation phenomena were evaluated by average and final relative turbidity indices. Turbidity and flocculation showed inverse relationship, i.e. the turbidity decreased with the formation of flocs. Relative turbidity of the stock treated with microparticle system was lower than that of the stock containing single polymer system, which indicated that the microparticle system showed greater floc forming efficiency than single polymer system.

Delineation Of Coastal Features And Relative Turbidity Levels In The Mid West Sea Of Korea Using Landsat Imagery

  • Youn, Oong Koo;Lee, Byung Don;Kwak, Hi-Sang
    • 한국해양학회지
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 1976
  • Multispectral scanner data collected by LANDSAT-1 over the mid West Sea of Korea were analyzed and interpreted for delineation of coastal features and turbidity distribution patterns during different portions of the tidal cycle. Imagery from two successful LANDSAT-1 overpasses of the area in October 1972 and in October 1973 had been used to prepare schematic maps of coastal features and turbidity distributions. Color composite imagery of LANDSAT MSS 4, 5 and 7 gave the best representation of shorelines, coastlines and tidal flats. MSS 5 imagery was most effective in differentiating relative turbidity levels through density slicing techniques. Referring to the tidal power development of Garolim Bay, the basin area measurements assuming dyke construction at the bay entrance, have been carried out on the coastal reature maps comiled from LANDSAT imagery, and those results were correlated with existing data. General areal patterns of surface turbidity distribution in the study area revealed close similarity with bathymetry of the area. Synoptic circulation patterns were also well discriminated from the LANDSAT imagery using the suspended sediment as a tracer.

  • PDF

Evaluation of particulate removal in slow sand filtration processes (완속여과 공정에서 전처리 공정 도입에 따른 입자제거 효율평가)

  • Kim, Seong-Su;Bae, Chul-Ho;Park, No-Suk;Kang, Suk-Hyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.461-466
    • /
    • 2008
  • Because of their simplicity, efficiency, and economy, slow sand filters are appropriate means of water treatment for small water systems. In this study, the effect of filtration velocity and dirty skin (Schmutzdecke) was evaluated on the performance of turbidity removal. Also, removal characteristics of particulate were investigated in the case of the usage of non-woven fabric on the surface of sand and the application of PCF as pretreatment process. Comparative column tests were carried out for the various operation condition. From the result of column tests, filtration velocity had little effect on the turbidity removal rate. The formation of algal biofilm on the surface of media is helpful in turbidity removal, while non-woven fabric is not as effective as expected. The relative contribution of biomass and accumulated particulates to head loss development in slow sand filters requires further study.

Daily Variations of Water Turbidity and Particle Distribution of High Turbid-Water in Paltang Reservoir, Korea (팔당호에서 수중 탁도의 일 변동과 고탁수의 입자 분포)

  • Shin, Jae-Ki;Kang, Chang-Keun;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.257-268
    • /
    • 2003
  • Daily monitoring was conducted to elucidate the changes in turbidity and distribution of particles in the turbid water of a river-type reservoir (Paltang Reservoir) from 1999 to 2001. Water turbidity and the particle distribution of turbid water were principally affected by meteorological factors particularly rainfall patterns and hydrological factors such as inflow and outflow. The mean concentration of turbidity was constant each year, with the concentration of less than 10 NTU accounting for 85%. Seasonal characteristics were remarkable, with winter and spring having < 5 NTU, autumn 5 ${\sim}$ 10 NTU, and summer > 20 NTU. Unlike hydrological changes, maximum turbidity was observed from late July to early August and continuously increased from 1999 to 2001. In particular, the maximum turbidity of reservoirs remarkably increased toward the lower part of reservoir in 2001. Discharge and turbidity increased or decreased slowly in 1999; in contrast, turbidity rapidly increased in the early rainfall period of 2000 and 2001 but later decreased as discharge increased. In the particles of turbid water, clay ingredients were more densely distributed and more dominant in all stations. Of the total particles in turbid water, clay constituted 63.9${\sim}$66.6% and silt 33.4${\sim}$36.1% to account for a combined total of 98.9 ${\sim}$ 100%. Sand made up less than 1.1%. The turbidity of river-type reservoir was also found to be mainly affected by the biomass of plankton in a non-rainfall period. During a rainfall period, however, the quantity and relative ratio of inorganic particles depending on the soil components affected turbidity.

A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent (하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구)

  • Paik, Ke-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.36-43
    • /
    • 2005
  • Prior to the study of the sewage treatment methods, water quality for Gwangju sewage of fluent was investigated from January to December, 2004 for sewage water reuse. Monthly mean values of BOD, SS, turbidity, total phosphorus and color were 4.1 mg/L, 2.9 mg/L, 0.8 NTU, 1.3 mg/L, and 27 unit, respectively. Jar-test was performed to investigate the removal efficiency of pollutants under the coagulation conditions of fast mixing for 5 min, slow mixing for 15 min and precipitation for 1hr. Here, alum and polyaluminium chloride (PAC) were used as coagulants to reduce color, turbidity, total phosphorus (TP) and total organic carbon (TOC) in sewage effluents. The results showed that PAC gave better efficiency in removing turbidity and dissolved phosphorus than alum. It was also found from the relative molecular weight (RMW) distribution analysis that organic matter over 1,000 Dalton (Da) was easily removed by coagulation and subsequently MF treatment, while it was not effective for less than 500 Da. Based on tis result, Natural organic matter (NOM) with lower molecular weight (< 500 Da) may cause harmful disinfectant by-product (DBP) after chlorine treatment. Thus, activated carbon adsorption seems to be required for the complete removal of DBP in the hybrid system.

Effects of Chitosan Coating for Liposomes as an Oral Carrier

  • Lee, Chang-Moon;Kim, Dong-Woon;Lee, Ki-Young
    • Biomedical Science Letters
    • /
    • v.17 no.3
    • /
    • pp.211-216
    • /
    • 2011
  • The chitosan-coated liposomes (chitosomes) were designed to improve the stability in the gastrointestinal (GI) tract and to enhance the efficacy for oral drug delivery of liposomes. The phosphatic acid (PA)-incorporated anionic liposomes were surface-coated with water soluble chitosan (WSC) by electro-ionic interaction. The shape of the chitosomes observed by transmission electron microscopy (TEM) was spherical in all the formulations and the coating layer by WSC could be founded through TEM images. The mean size and the zeta potential values of the chitosomes increased significantly with depending on the content of WSC added for coating the liposomes. The stability of the chitosomes in the GI tract was confirmed through the change of relative turbidity of the liposomal suspension. The plain liposomes (plasomes) suspension without adding WSC clearly showed the change of relatively turbidity in simulated gastric fluid (SGF), while the change degree of turbidity of the chitosomes in the SGF decreased as increasing of WSC content added for coating liposome. In the 5-CF release study from the plasomes and chitosomes, the plasomes released >90% of the initial 5-CF content at 4 h of release measurement. In contrast, the chitosomes released below 40% of initial content of 5-CF. In conclusion, these results indicate that the chitosomes can be used as a potential carrier for effective oral drug delivery.

The Experimental Study of Predicting Optimum Dosage of PAC Using Jar-Test Results (Jar-Test를 이용(利用)한 응집제(凝集劑) 주입율(注入率) 결정(決定)에 관한 실험연구(實驗硏究))

  • Kim, Hong Seog;Kim, Seong Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.2
    • /
    • pp.39-46
    • /
    • 1993
  • In this experimental study, it is concerned to develop a simple equation using jar-test results in order to predict the optimum dosage of coagulant, PAC(polyaluminum chloride). Considering the relationships with the reactions of coagulation and flocculation, the four independent variables (e.g. turbidity, temperature, pH and alkalinity) are selected out of many parameters and they are put into calculations to develop an equation by means of multi-regression method. As the result, the dosing rate of PAC is proportional to turbidity, pH and alkalinity, but in inverse to temperature. And the developed equation is as follow, $$D_c=\frac{3.2{\cdot}T^{0.37}{\cdot}A^{0.04}{\cdot}P^{0.5}}{t^{0.1}},\;(R^2=0.9443)$$ And also, comparing between the estimated value from the equation and the real dosing rate in the plant, Kwangam and Tdukdo, during 1988~1991, it is represented an agreement having a relative error of 16.4%, 17.8%, respectively.

  • PDF

Bundle Adjustment and 3D Reconstruction Method for Underwater Sonar Image (수중 영상 소나의 번들 조정과 3차원 복원을 위한 운동 추정의 모호성에 관한 연구)

  • Shin, Young-Sik;Lee, Yeong-jun;Cho, Hyun-Taek;Kim, Ayoung
    • The Journal of Korea Robotics Society
    • /
    • v.11 no.2
    • /
    • pp.51-59
    • /
    • 2016
  • In this paper we present (1) analysis of imaging sonar measurement for two-view relative pose estimation of an autonomous vehicle and (2) bundle adjustment and 3D reconstruction method using imaging sonar. Sonar has been a popular sensor for underwater application due to its robustness to water turbidity and visibility in water medium. While vision based motion estimation has been applied to many ground vehicles for motion estimation and 3D reconstruction, imaging sonar addresses challenges in relative sensor frame motion. We focus on the fact that the sonar measurement inherently poses ambiguity in its measurement. This paper illustrates the source of the ambiguity in sonar measurements and summarizes assumptions for sonar based robot navigation. For validation, we synthetically generated underwater seafloor with varying complexity to analyze the error in the motion estimation.

A Study on the Development and the Verification of a Sonar Sensor System of a Socket Roughness Measurement Device for A Lagre-diamter Drilled Shaft (대구경 현장타설말뚝의 소켓 벽면 거칠기 측정장치(SRPS)에 사용되는 소나센서부의 개발 및 검증에 관한 연구)

  • Jeon, Byeong-Han;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.87-98
    • /
    • 2012
  • A sonar sensor system of a new socket roughness profiling system (SRPS) which can measure the socket roughness of the large-diameter drilled shafts under the in-situ condition was developed and verified. In model tests, the salinity, temperature, and high-turbidity have been changed for simulating the in-situ borehole water conditions. From the test results, it was found that the sonar sensor can measure the distance within an accuracy of 1mm. Because of the wave form characteristics of sonar sensor, the relative error exists in case of the inclined and curved surface, however, the shape of specimen was confirmed relatively exactly using the developed sonar sensor. Moreover, the salinity, temperature, and high-turbidity did not affect the measured data of socket roughness.