• Title/Summary/Keyword: relative surface area

Search Result 395, Processing Time 0.025 seconds

Y-TZP Sintered with Spherical Fine Powders Prepared by Ultrasonic Spray Pyrolysis (초음파 분무 열분해 구형 미립자를 이용한 Y-TZP 소결체의 제조)

  • 김복희;이정형
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.5
    • /
    • pp.575-581
    • /
    • 1995
  • Zr0.94Y0.06O1.97 powder was synthesized by the ultrasonic spray pyrolysis with various concentrations of starting solution and the influence of powder characteristics on sintering behavior was investigated. Powders prepared at 75$0^{\circ}C$ were characterized as narrowly distributed submicron spherical particles, which were crystalline, nonagglomerated, and compositionally homogeneous. The changes in concentration from 0.01 to 01. mol/ι increased mean particle size from 0.24 to 0.38${\mu}{\textrm}{m}$ and decreased the specific surface area from 14.2 to 2.9$m^2$/g. The relative density of the specimen from the powders, prepared with the solution concentration of 0.01 mol/ι, was 98% after sintering for 2 hr at 1,45$0^{\circ}C$ and the monoclinic phase was observed after sintering at 1,55$0^{\circ}C$. As the concentration of starting solution was increased, the formation temperature of monoclinic phase was lowered.

  • PDF

The Adsorption Characteristics of a Granular Active Carbon by the Physical Properties (입상 활성탄의 물리적특성 변화에 따른 흡착특성)

  • 김덕기;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.1
    • /
    • pp.84-89
    • /
    • 1996
  • The adsorption characteristics of active carbon used as a cartridge filler of organic vapor respirator were examined by humidity, particle size, challenge concentration and specific surface area. As a result, the 1% breakthrough time of Carbon Tetrachloride($CCl_4$) was decreased with increase of relative humidity, challenge concentration and particle size (0.6~2.0mm) of active carbon. The adsorbed amount of $CCl_4$ was about 1. 1mg/$m^2$ at RH 40% and 0. 5mg/$m^2$ at RH 80% . However in the case of prehumidified active carbon, humidity did not affected to 1% breakthrough time up to RH 40%.

  • PDF

A Study of the appraisal for adhesive stability classified by tile bond agent on the dry wall surface (건식벽체에서 접착제 종류에 따른 타일부착 안전성 평가에 관한 연구)

  • Um Chan-Young;Sun Yoon-Suk;Kwon Shi-Won;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.173-178
    • /
    • 2005
  • The tile construction methods for existing have been used materials within limit which adhesion by wet method in masonry wall and concrete structure. These existing adhesive tech can caused many problems in construction of large and reform tile, after that it can be happened loose scale, peel off, falling off tile by heat and vibration or impact. In according to, this study is to test tile for bond stability, adhesive property by impact, vibration. low property by heat and then, we have the results as below; (1) The tile adhesive stability can be effected as adhesive area between bond agent and tile, adhesive area can more wide and press enough to ensure property. (2) Existing adhesive strength and standard relative tile construction is limited to adjust performance tile on the concrete and masonry wall. In summary, It is necessary to establish standard of performance and test method to ensure tile adhesive salability in dry wall.

  • PDF

The Impact of the Dam Construction on the Fog Characteristics of Its Surrounding Area (대형 댐 건설이 주변 지역의 안개 특성에 미친 영향 - 주암댐과 충주댐을 사례로 -)

  • Lee, Seungho;Heo, Inhye
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.2
    • /
    • pp.109-120
    • /
    • 2003
  • This paper examined the impacts of dam construction on fog characteristics over surrounding areas. Juamdam which only supplies the water for use and Chungjudam which generates electricity were selected. The number of foggy days, fog occurrence and dissipation time and the differences of each lake water temperature and air temperature at Sunchun and Chungju were analyzed. After the construction of dam, the relative humidity and water vapor pressure were decreased at Sunchun and Chungju. The number of foggy days did not increase at Sunchun while largely increased at Chungju. Just because Juamdam were contained water, the water vapor pressure at surrounding areas of the weather station were largely decreased. It delayed the time of fog occurrence by bringing out the decrease of steam fog. The foggy days increased over the Chungju area due to the difference between air and cold outlet water temperature. The increase of foggy days mainly resulted from evaporation during colder seasons and from the temperature inversion over the water surface during warmer seasons.

Modern Dinoflagellate Cysts Distribution off the Eastern Part of Geoje Island, Korea

  • Shin, Hyeon-Ho;Yoon, Yang-Ho;Matsuoka, Kazumi
    • Ocean Science Journal
    • /
    • v.42 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • Distributional characteristics of dinoflagellate cysts in surface sediments were investigated in relation to environmental factors in the eastern part of Geoje Island, Korea. Samples were collected from 10 stations in February of 2004 and water temperature and salinity were measured in February, May, September and November of 2004. Total 30 taxa of dinoflagellate cysts were identified representing 19 genera, 28 species and 2 unidentified species. Among these dinoflagellate cysts, Brigantedinium spp. of which relative proportion in th e total dinoflagellate cysts was 23.5%, was the most abundant at all stations except St. 1, and was followed by Spiniferites bulloideus (8.6%), Lingulodinium machaerophorum (8.2%) and Diplopsalis lenticula (6.7%). In addition, ellipsoidal cysts of the genus Alexandrium (Alexandrium catenella - tamarense type) and Gymnodinium catenatum, known to be causative organisms for PSP, occurred with high concentrations. Scrippsiella trochoidea was also found; however, its cyst concentration was low. Generally, species composition in the study area was similar to these reported from Jinhae Bay and Busan Harbor and several dinoflagellate cysts reflected the eutrophic condition. Cyst distribution in th e eastern part of Geoje Island seems to be influenced by the Tsushima Warm Current flowing from the southwest. The mean water temperature was $12.0^{\circ}C$ in February, $14.7^{\circ}C$ in May, $20.9^{\circ}C$ in September and $17.2^{\circ}C$ in November, which was most favorable for Alexandrium spp. growth. The abundances of dinoflagellate cysts rang e d from 528 to 2,834 cysts/g dry sediment. Higher concentrations were recognized in sediments of west area of the Jisimdo than at other stations. The cyst composition of this area was closely related to these of Jinhae Bay and Busan Harbor from which currents flow into this area. Higher cyst concentration in the west area of Jisimdo might be due to formation of the gyre.

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

The application of ecosystem model for the eutrophication control in Masan Bay in summer (하계 마산만의 부영양화 제어를 위한 생태계모델의 적용)

  • Kim, Jong-Gu;Park, Cheong-Gil;Kim, Gwang-Su
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.185-195
    • /
    • 1994
  • Masan bay is one of the polluted enclosed bays, which has red tides problem and the formation of oxygen deficient water in the bottom layer. Most important factors that cause eutrophication and red tide is nutrient materials containing nitrogen and phosphorus which stem from terrestrial sources and nutrients released from sediment. Therefore, to improve of water quality, reduction of these nutrient loads should be indispensible. At this study, the three-dimensional numerical hydrodynamic and eutrophication model, which were developed by Institute for Resources and Environment of Japan, were applied to analyze the processes affecting the phytoplankton production and also to evaluate the effect of water quality improvement plans on phytoplankton production. In field sorvey, the range of concentrations of chlorophyll-a at surface area was found to be 29.17 - 212.5mg/m3, which were exceeding eutrophication criteria. The constant currents defined by integrating the simulated tidal currents over 1 tidal cycle showed the counterclockwise eddies in the southern part of Budo. The general directions of constant currents were found to be southward at surface and northward at bottom over all the bay. The eutrophication model was calibrated with the data surveyed in the field area in June, 1993. The calculated results are in fairly good agreement with values within relative error of 30%. The pollutant load from the sources such as the input from terrestrial release from the sediment was reduced by the rate of 50, 70, 90, 98% to effect of phytoplankton production. Phytoplankton production was reduced to of the 90% reduction of the input loads from terrestrial sources and 8% in 90% reduction of the load from sediment.

  • PDF

Drying and Shrinking Characteristics of Food 1. Shrinking Phenomena during Drying of Sea Tangle (식품의 건조 및 수축특성에 관한 연구 - 1. 다시마 건조중의 수축현상 -)

  • CHO Duck-Jae;HUR Jong-Hwa;CHUNG Soo-Yeol
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.11-15
    • /
    • 1988
  • Square slices of sea tangle was dried in constant condition of thickness (1.54mm), air temperature $(50^{\circ}C)$, relative humidity $(30\%)$ and air velocity (0.4m/s). The shrunk surface area and the shrinking rate were investigated. The results obtained are summarized as follows : 1) Comparing the shrinking of transverse section with that of vertical section, the transverse section was proceeded more double shrinkage than vertical section. 2) The shrunk surface area curve showed nearly a linear shrinkage up to 90min of drying time. 3) The shrinking rate was rapidly increased in first falling rate period, and was largest in the early period of second falling rate period.

  • PDF

Analysis of the West Coast Heavy Snowfall Development Mechanism from 23 to 25 January 2016 (2016년 1월 23일~25일에 발생한 서해안 대설 발달 메커니즘 분석)

  • Lee, Jae-Geun;Min, Gi-Hong
    • Atmosphere
    • /
    • v.28 no.1
    • /
    • pp.53-67
    • /
    • 2018
  • This study examined the lake effect of the Yellow Sea which was induced by the Siberian High pressure system moving over the open waters. The development mechanism of the convective cells over the ocean was studied in detail using the Weather Research and Forecasting model. Numerical experiments consist of the control experiment (CTL) and an experiment changing the yellow sea to dry land (EXP). The CTL simulation result showed distinct high area of relative vorticity, convergence and low-level atmospheric instability than that of the EXP. The result indicates that large surface vorticity and convergence induced vertical motion and low level instability over the ocean when the arctic Siberian air mass moved south over the Yellow Sea. The sensible heat flux at the sea surface gradually decreased while latent heat flux gradually increased. At the beginning stage of air mass modification, sensible heat was the main energy source for convective cell generation. However, in the later stage, latent heat became the main energy source for the development of convective cells. In conclusion, the mechanism of the west coast heavy snowfall caused by modification of the Siberian air mass over the Yellow Sea can be explained by air-sea interaction instability in the following order: (a) cyclonic vorticity caused by diabatic heating induce Ekman pumping and convergence at the surface, (b) sensible heat at the sea surface produce convection, and (c) this leads to latent heat release, and the development of convective cells. The overall process is a manifestation of air-sea interaction and enhancement of convection from positive feedback mechanism.

Frequent Forest Fire in Kosong-Gun, Kangwon Province (고성지방의 산불발생)

  • 이장렬
    • The Korean Journal of Quaternary Research
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • In this paper, the writer attempts to clarify causes by general man and weather factor on forest fire occurrence in Kosong-Area, 1995-2001. The major results are summarized as follows: The forest fire at Kojin-ri, Sonyusil-ri and Majwa-ri occurred at the same area over 3 times and that Hakya-ri, Songdae-ri and Inhung-ri, at the adjoining land over 3times. In the total 46 times of forest fire, fire frequence was greatest in March(11 time) and April(11 time) followed by November(7 time), January(6 time), February(6 time). December(3 time), October(2 time). Hours on frequent forest fire are from 11:00 till 18:00. Number for forest fire occurrence by causes was greatest in military training followed by burning paddy fields, debris burning, burning agricultural debris, visiting a grave, cigarette and arson. Frequent forest fire in Kosong-Area coincide not only with above normal temperatures, but also with below normal relative humidity. When the strong winds appear at Kosong-Area, the properties of daily surface chart re the south high and north low pressure pattern in the Far East Asia.

  • PDF