• Title/Summary/Keyword: relative risk assessment

Search Result 204, Processing Time 0.018 seconds

Impact of Weather on Prevalence of Febrile Seizures in Children (소아의 열성경련에 날씨가 미치는 영향)

  • Woo, Jung Hee;Oh, Seok Bin;Yim, Chung Hyuk;Byeon, Jung Hye;Eun, Baik-Lin
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.227-232
    • /
    • 2018
  • Purpose: Febrile seizure (FS) is the most common type of seizure in children between 6 months to 5 years of age. A family history of febrile seizures can increase the risk a child will have a FS. Yet, prevalence of FS regarding external environment has not been clearly proved. This study attempts to determine the association between prevalence of FS and weather. Methods: This study included medical records from the Korea National Health Insurance Review and Assessment Service. Data were collected from 29,240 children, born after 2004, diagnosed with FS who were admitted to one of the hospitals in Seoul, Korea, between January 2009 and December 2013. During the corresponding time period, data from the Korea Meteorological Administration on daily monitoring of four meteorological factors (sea-level pressure, amount of precipitation, humidity and temperature) were collected. The relationships of FS prevalence and each meteorological factor will be designed using Poisson generalized additive model (GAM). Also, the contributory effect of viral infections on FS prevalence and weather will be discussed. Results: The amount of precipitation was divided into two groups for comparison: one with less than 5 mm and the other with equal to or more than 5 mm. As a result of Poisson GAM, higher prevalence of FS showed a correlation with smaller amount of precipitation. Smoothing function was used to classify the relationships between three variables (sea-level pressure, humidity, and temperature) and prevalence of FS. FS prevalence was correlated with lower sea-level pressure and lower humidity. FS prevalence was high in two temperature ranges (-7 to $-1^{\circ}C$ and $18-21^{\circ}C$). Conclusion: Low sea-level pressure, small amount of precipitation, and low relative air humidity may increase FS prevalence risk.

Development and validation of an analytical method for fungicide fenpyrazamine determination in agricultural products by HPLC-UVD (HPLC-UVD를 이용한 살균제 fenpyrazamine의 시험법 개발 및 검증)

  • Park, Hyejin;Do, Jung-Ah;Kwon, Ji-Eun;Lee, Ji-Young;Cho, Yoon-Jae;Kim, Heejung;Oh, Jae-Ho;Rhee, Kyu-Sik;Lee, Sang-Jae;Chang, Moon-Ik
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.172-180
    • /
    • 2014
  • Fenpyrazamine which is a pyrazole fungicide class for controlling gray mold, sclerotinia rot, and Monilinia in grapevines, stone fruit trees, and vegetables has been registered in republic of Korea in 2013 and the maximum residue limits of fenpyrazamine is set to grape, peach, and mandarin as 5.0, 2.0, and 2.0 mg/kg, respectively. Very reliable and sensitive analytical method for determination of fenpyrazamine residues is required for ensuring the food safety in agricultural products. Fenpyrazamine residues in samples were extracted with acetonitrile, partitioned with dichloromethane, and then purified with silica-SPE cartridge and eluted with hexane and acetone mixture. The purified samples were determined by HPLC-UVD and confirmed with LC-MS and quantified using external standard method. Linear range of fenpyrazamine was between $0.1{\sim}5.0{\mu}g/mL$ with the correlation coefficient (r) 0.999. The average recovery ranged from 71.8 to 102.7% at the spiked level of 0.05, 0.5, and 5.0 mg/kg, while the relative standard deviation was between 0.1 and 7.3%. In addition, limit of detection and limit of quantitation were 0.01 and 0.05 mg/L, respectively. The results revealed that the developed and validated analytical method is possible for fenpyrazamine determination in agricultural product samples and will be used as an official analytical method.

Depression, Anxiety, Alexithymia, Stress Response in Caregivers of Attention Deficit Hyperactivity Disorder Patient (주의력결핍 과잉행동장애 환아 보호자의 우울, 불안, 감정표현불능, 스트레스반응)

  • Jeong, Jong-Hyun;Hong, Seung-Chul;Han, Jin-Hee;Lee, Sung-Pil
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.13 no.2
    • /
    • pp.95-101
    • /
    • 2005
  • Objectives : This study was designed to investigate depression, anxiety, alexithymia, stress res ponses in caregivers of patients with attention deficit hyperactivity disorder. Methods : The subjects were 38 attention deficit hyperactivity disorder patients caregivers(38 women, mean age $37.5{\pm}6.5$). Patients were diagnosed with DSM-IV ADHD criteria. Korean version of Beck Depression Inventory(BDI), State and Trait Anxiety Inventory(STAI), Toronto Alexithymia Scale(TAS) and Stress Response Inventory(SRI) were used for assessment. Results 1) The BDI scores of ADHD patients caregiver group were significantly higher than control group$(16.4{\pm}7.1\;vs.\;10.9{\pm}5.5)(p=0.011)$. 7 of the 38 caregivers(18.4%) and none of control group(0%) had BDI scores over 20 points(p=0.021). Calculated relative risk for ADHD in the presence of caregivers' depression was 1.516 overall(95% confidence interval, 1.234-1.862). 2) In ADHD patient's caregiver group, the scores of Stress Response Inventory were significantly higher than control group$(44.2{\pm}20.2\;vs.\;26.5{\pm}16.8)(p=0.006)$. 3) No significant differences were found in the score of STAI, SIAIS, SIAI-T, TAS between caregiver and control group. Conclusion : This study suggest that ADHD patients' caregivers are likely to have more depressive symptoms and higher stress response level than control group. We propose that physicians should consider integrated approaches for caregiver's psychopathology in the management of ADHD.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.