• Title/Summary/Keyword: relative impedance measurement

Search Result 31, Processing Time 0.024 seconds

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil (토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석)

  • Ahn, Chang-Hwan;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Measurement System: Pilot Study

  • Kim, Jaehyung;Shin, Beumjoo;Jeon, Gyerok
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.2
    • /
    • pp.123-130
    • /
    • 2017
  • The early detection of intravenous (IV) infiltration is necessary to minimize the injury caused by the infiltration, which is one of the most important tasks for nurses. For detecting early infiltration in patients receiving invasive vein treatment, bioelectrical impedance was measured using multi-frequency bioelectrical impedance. The impedance decreased significantly at infiltration, and then decreased gradually over time after infiltration. The relative impedance at 20 kHz decreased remarkably at infiltration, and then gradually decreased thereafter. In addition, the impedance ratio increased temporarily at infiltration and then gradually decreased over time. Furthermore, the impedance at each frequency decreased quantitatively over time. This indicates that IV solution leaking from the vein due to infiltration accumulates in the subcutaneous tissues. Moreover, slopes of log Z vs. log f differently decreased with increasing log f, indicating that the impedance exhibits different responses depending on the frequency.

Relative Measurement of Differential Electrode Impedance for Home Healthcare Device (Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정)

  • Woo, Y.J.;Yoo, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

  • PDF

Fabrication of electrodes on mcirochannel side wall using shadow evaporation effect (샤도우 증착 효과를 이용한 마이크로 채널내 측벽 전극 제작)

  • 강길환;김규만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1462-1465
    • /
    • 2004
  • A new method to fabricate metal electrodes on side wall of the microchannel is presented. Coulter counter allows to count the number of cell passing through the microchannel by detecting impedance variation between two electrodes. The relative position of two electrodes is important for sensitivity of impedance measurement. 100nm thick Al electrodes are deposited on the channel side wall by means of shadow evaporation.

  • PDF

Probing of Steel Bar Location inside Concrete using Multi-electrode Array (다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사)

  • 이형우;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

A Study on Dielectric Properties of Printed Circuit Board(PCB) Materials with Variation of Frequency and Temperature using Coaxial Air Line Probe (동축선로 프로브를 이용한 프린트 배선 회로용 기판 재료의 주파수 및 온도 변화에 따른 유전특성 연구)

  • 박종성;김종헌
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.187-190
    • /
    • 1998
  • In this paper a probe for the' measurement of dielectric properties of dielectric sheet materials is designed and implemented as a coaxial air line type. Using the broadband impedance method with this measurement probe the dielectric constant and loss tangent of the glass-epoxy and teflon are determined in the frequency range of 0.1 - l.O[GHz] with the temperature variation from $25[^{\circ}C]$ up to $65[^{\circ}C]$. A measured relative dielectric constant of the glass-epoxy is 4.42 and a loss tangents is 0.019 relatively, and the relative dielectric constants of teflon is 2.17 and a loss tangents is 0.002 relatively

  • PDF

APPLICATION OF IMPEDANCE SPECTROSCOPY TO POLYCRYSTALLINE SI PREPARED BY EXCIMER LASER ANNEALING (임피던스 측정법을 이용한 엑시머 레이져 열처리 Poly-Si의 특성 분석)

  • 황진하;김성문;김은석;류승욱
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.200-200
    • /
    • 2003
  • Polycrystalline Si(polysilicon) TFTs have opened a way for the next generation of display devices, due to their higher mobility of charge carriers relative to a-Si TFTs. The polysilicon W applications extend from the current Liquid Crystal Displays to the next generation Organic Light Emitting Diodes (OLED) displays. In particular, the OLED devices require a stricter control of properties of gate oxide layer, polysilicon layer, and their interface. The polysilicon layer is generally obtained by annealing thin film a-Si layer using techniques such as solid phase crystallization and excimer laser annealing. Typically laser-crystallized Si films have grain sizes of less than 1 micron, and their electrical/dielectric properties are strongly affected by the presence of grain boundaries. Impedance spectroscopy allows the frequency-dependent measurement of impedance and can be applied to inteface-controlled materials, resolving the respective contributions of grain boundaries, interfaces, and/or surface. Impedance spectroscopy was applied to laser-annealed Si thin films, using the electrodes which are designed specially for thin films. In order to understand the effect of grain size on physical properties, the amorphous Si was exposed to different laser energy densities, thereby varying the grain size of the resulting films. The microstructural characterization was carried out to accompany the electrical/dielectric properties obtained using the impedance spectroscopy, The correlation will be made between Si grain size and the corresponding electrical/dielectric properties. The ramifications will be discussed in conjunction with active-matrix thin film transistors for Active Matrix OLED.

  • PDF

CO Gas Response Characteristic and Electrical Properties of ZnO-TiO$_2$Composite (ZnO-TiO$_2$ 복합체의 전기적 성질과 일산화탄소 감응특성)

  • 김태원;최우성;박춘배;정승우;소병문;백승철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.103-106
    • /
    • 1997
  • The electrical properties and the sensing properties of ZnO-TiO$_2$ composites were investigated by using the complex impedance measurement and voltage-current source and measurement unit. In air, the electrical conductivity of TiO$_2$ added ZnO increase with increasing the content of TiO$_2$ and the relative dielectric constants for 3, 5 and 7mol% TiO$_2$ added ZnO are 7, 13 and 120, respectively. In 3000ppm CO gas, the relative dielectric constants for 3, 5mol% TiO$_2$ added ZnO are 25, 28, respectively.

  • PDF

Electrical Properties of TiO$_2$dopen ZnO (TiO$_2$가 첨가된 ZnO의 전기적성질)

  • 최우성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.22-24
    • /
    • 1995
  • The electrical conductivity of TiO$_2$doped ZnO was investigated by means of complex impedance measurement and voltage-current source and meaurement unit. The e1ectrical conductivity of TiO$_2$added ZnO was increased with increasing the concentration of TiO$_2$. The calculated relative dielectric constant was decreased with increasing the concentration of TiO$_2$. The increase of electrical conductivity seems to be the effect of TiO$_2$donor doping.

  • PDF