A Biomechanical Analysis in the Neck Injury according to the Position of Read Restraint During Low Speed Rear-End Impacts (저속 정후면 추돌시 머리구속장치 위치에 따른 목 상해에 관한 생체 역학적 연구)

  • Jo Huichang;Kim Youngeun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.132-139
    • /
    • 2005
  • The driving position of head restraints and the relative risk of neck injury were studied in the computer simulation. MADYMO human model with the detail neck model was used to define the magnitude and direction of internal forces acting on the cervical spine during rear-end impact and to determine the effect of the initial position of the occupant's head with respect to the head restraints. Maximum reaction forces were generated during the head contact to the restraint and relatively large forces were generated at each spinal components in lower cervical spine in proportion to backset and height distance increasement.

Effects of Tumble Adaptor Configurations on the Intake Tumble Characterization (텀블-스월 변환장치 형상이 흡입텀블 특성화에 미치는 영향)

  • Kang, K.Y.;Lee, J.W.;Baek, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.66-73
    • /
    • 1994
  • The configuration effects of a tumble adaptor which transforms tumble into swirl on the intake tumble characterization under steady flow condition have been investigated by LDV measurement The following parameters were involved to test their effects on tumble-swirl conversion characteristics ; the cylinder height and its bottom shape, measuring position in the swirl induction pipe, and the relative direction of the induction pipe. The short cylinder height and the flat bottom of the tumble adaptor were found effective for the generation of tumble in the cylinder, allowing higher tumble-swirl conversion efficiency.

  • PDF

A Study on the Vibration and Dropping Shock of Refrigerator during Physical Distribution (냉장고의 유통 중 진동 및 낙하충격에 관한 연구)

  • Lee, Soo-Keun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.8 no.1
    • /
    • pp.23-26
    • /
    • 2002
  • This study was carried out to investigate vibration shock and dropping shock of refrigerator during physical distribution. The values of vibration shock were measured to be ${\sim}3G$ for up and down direction, ${\sim}0.8G$ for right and left direction and ${\sim}0.5G$ for back and forth direction on the national road. There was no damage during transport. From the results of dropping test by KS A 1026(General Rules of Performance Testing for Packaged Freights), relative equations were gained as follow : y = 0.12x + 7.63(where y is G-factor and x is Dropping height). The maximum values of dropping shock during materials handling were measured to be 11G. This shock value was corresponding to dropping shocks of dropping height 28.3cm by KS A 1026.

  • PDF

The Economics of Skyscraper Construction in Manhattan: Past, Present, and Future

  • Barr, Jason
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.2
    • /
    • pp.137-144
    • /
    • 2016
  • This paper discusses the economics of skyscraper construction in Manhattan since 1990. First the paper reviews the economic theory of skyscraper height. Next it documents the frequency and heights of skyscraper construction in the last 25 years. Then the paper reviews the relative movements of office rents, condominium prices, and construction costs. Statistical results suggest that the resurgence of Manhattan's skyscraper construction is being driving by the rise in the average price of apartments, and is not being driven by rising office rents or falling construction costs. Statistical evidence shows that the height premium has not been rising over the last decade. Developers have been purchasing air rights (and bidding up the prices) in order to satisfy the demand for supertall buildings. In the next five to ten years, Manhattan is likely to see over thirty 200-meter or taller buildings, as compared to only four since 2010.

Theoretical Performance Analysis of a Modified Rectangular Fin (변형된 사각 핀의 이론적 성능해석)

  • 강형석;김영준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.683-690
    • /
    • 2004
  • A modified rectangular fin is analyzed by two-dimensional analytic method and finite difference method. Relative error of heat loss from the modified rectangular fin between analytic method and finite difference method is presented. Comparisons of fin effectiveness and heat loss between a modified rectangular fin and a plane rectangular fin are made as a function of the non-dimensional fin length and wing height for different positions of wings by using analytic method. The ratio of the incremental rate of heat loss to that of the area of a modified rectangular fin is shown as a function of the wing height. One of the results shows that performance of a modified fin is more improved as the wing approaches the fin root.

The Characteristic Analysis of the Cross-shaped Microstrip Slot Antenna with the Reflector for Permittivity and Height of Dielectrics

  • Jang, Yong-Woong;Shin, Ho-Sub;Oh, Dong-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.183-186
    • /
    • 2000
  • We analyzed the cross-shaped microstripline-fed slot antenna with the reflector using FDTD(Finite-Difference Time-Domain) method in this paper. The proposed antenna uses RR Duroid-5880 substrate(relative permittivity 2.2 and height(1.578 mm) of dielectrics), and compares the optimized results of other kind substrates. The maximum bandwidth of the proposed antenna is from 1.91 GHz to 5.21 GHz, which is approximately 1.437 octave for the VSWR $\leq$ 2. It was found that the bandwidth of the antenna depend highly on the length of the horizontal and vertical feedline as well as the offset position of the feedline. The experimented data for the VSWR and the radiation pattern of the antenna are also represented.

  • PDF

Rib Effect of Deformation on Bond Strength (부착강도에 대한 이형철근의 마디형상 영향)

  • Park, Young-Su;Yang, Seung-Yul;Kim, Byoung-Kook;Hong, Gi-Suop;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.209-212
    • /
    • 2006
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. The effects of defomation properties on bond of reinforcing bars to concrete are studied. Beam-end tests are used to investigate the effects of machining of bars in addition to rib angle and relative rib area. The test results show that bond strength of machined bars were higher than the conventional bars produced in factory. Higher rib height bars with rib angle $30^{\circ}{\sim}60^{\circ}$ showed higher bond strength than lower rib height bars with low angle.

  • PDF

Skinfold thickness and total body fat in children (사람의 피부두겹 및 총지방량에 관한 연구 - 제 2 편 아이의 피부두겹 두께 및 총지방량 -)

  • Cho, Yoon-Shik
    • The Korean Journal of Physiology
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1971
  • Body volume, density and %fat were calculated by means of formulas using body height, weight, and surface area in 1,732 children aged between 6 and 12 years. Skinfold thicknesses on back, arm, waist and abdomen were measured by means of a Lange caliper. The course of increase in body volume was identical to those of body height, weight, relative weight and surface area. Curves of boys and girls showed a cross at the age of between 10 and 11 years. Body density of boys increased with the age and it decreased in girls. Total body fat showed a progressive decrease from the age of 6 in boys. In girls body fat increased progressively with the age. Skinfold thickness increased both in boys and girls with the age. At the same age skinfold thicknesses on all sites were greater in girls than boys.

  • PDF

Distribution of near-fault input energy over the height of RC frame structures and its formulation

  • Taner Ucar
    • Structural Engineering and Mechanics
    • /
    • v.85 no.1
    • /
    • pp.55-64
    • /
    • 2023
  • Energy-based seismic design and evaluation methods are promising to be involved in the next generation design codes. Accordingly, determining the distribution of earthquake input energy demand among floor levels is quite imperative in order to develop an energy-based seismic design procedure. In this paper, peak floor input energy demands are achieved from relative input energy response histories of several reinforced concrete (RC) frames. A set of 22 horizontal acceleration histories selected from recorded near-fault earthquakes and scaled in time domain to be compatible with the elastic acceleration design spectra of Turkish Seismic Design Code are used in time history analyses. The distribution of the computed input energy per mass values and the arithmetic means through the height of the considered RC frames are presented as a result. It is found that spatial distribution of input energy per mass is highly affected by the number of stories. Very practical yet consistent formulation of distributing the total input energy to story levels is achieved, as a most important contribution of the study.

Relationship between Fat-Free Mass and Muscle Strength, Nutrient Intakes, Exercise Habits in Male Aged

  • Lee, Okhee;Kim, Kang-Sung
    • Nutritional Sciences
    • /
    • v.4 no.2
    • /
    • pp.112-119
    • /
    • 2001
  • This study was performed fir the purpose of finding the relationship between fat-free mass (FFM) which mainly represents muscle mass change, and muscle strength. The correlation between diet and exercise behaviors and FFM in healthy elderly men over age 55 was also investigated. FFM and corresponding hand grip strength declined significantly with increasing age. However the concentration of serum albumin, the indicator of protein nutritional status, showed no change with increases in age. The subjects were categorized into three groups according to FFM textiles. Anthropometry such as height, BMI, circumferences of waist and hips, body fat mass percent and hand grip strength decreased significantly in the lowest FFM group. But albumin level showed no change relative to FFM level. FFM showed a significant relationship to nutrient intake such as energy and fat. However, no association was found with exercise behavior probably because there were no instances of resistance exercise habits among the subjects studied. The variance in FFM could be attributed 86.2% to height and age. The variance of height-adjusted FFM could be attributed only 40.6% to age and fat intake. In conclusion decreases in FFM may cause reductions in muscle strength in elderly men. Increasing energy and fat intake were associated with increased FFM and may protect elderly men from the risk of sarcopenia. FFM had no association with endurance exercise habits.