• Title/Summary/Keyword: relative fluorescence intensity

Search Result 46, Processing Time 0.024 seconds

CHANGE OF VASOACTIVE INTESTINAL POLYPEPTIDE(VIP) IMMUNOREACTIVE CELLS FOLLOWING PULP EXTIRPATION IN RAT TRIGEMINAL GANGLION: A CONFOCAL LASER SCANNING MICROSCOPIC STUDY (치수제거 후 흰쥐 삼차신경절에서 VIP 면역반응세포의 변화: 공초점레이저주사현미경적 연구)

  • Kim, Heung-Joong;Kim, Seung-Jae;Park, Joo-Cheol;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.25-31
    • /
    • 2001
  • The purpose of this study was to investigate the distribution and fluorescence intensity of vasoactive intestinal polypeptide immunoreactive (VIP-IR) cells in rat trigeminal ganglion following pulp extirpation of rat mandibular molar. The animals were divided into control group(n=6) and experimental group(n=6). The experimental animals were sacrificed at 14 days after pulp extirpation. The trigeminal ganglion was removed and immersed in the 4% paraformaldehyde in 0.1M phosphate buffer. Serial frozen sections about $20{\mu}m$ in thickness were cut with a cryostat. The immunofluorescence staining was performed. The rabbit anti-VIP(1 : 8,000) was used as primary antibody and fluorescene isothiocynate(FITC) conjugated anti-rabbit IgG(1 : 80) as secondary antibody. The slides were observed under confocal laser scanning microscope (CLSM). Unprocessed optical sections were obtained and stored on a optical disk. Color pictures were printed by a video copy processor. The results were as follows; 1. The positive ratio of VIP-IR cells in mandibular part of trigeminal ganglion were 7.40% in control group and 28.42% in experimental group(14 days after pulp extirpation). 2. The relative fluorescence intensity of VIP-IR cells in mandibular part of trigeminal ganglion were 87.78 in control group and 138.65 in experimental group. The relative fluorescence intensity of experimental group was 58% higher than that of control group. 3. In optical serial section analysis of VIP-IR cells of experimental group, most of the 9 sections showed high fluorescence intensity. At high magnification, axons of the experimental group displayed greater VIP-IR than in the control group, and the positive cells were mainly of medium size. The result indicate that number and fluorescence intensity of VIP-IR cells were increased in the mandibular part of trigeminal ganglion following pulp extirpation of mandibular molar, and it suggests that VIP could play a role in processing of nociception.

  • PDF

Fluorescence Characteristic Analysis for Fiber Detection in Sectional Image of Fiber Reinforced Cementitious Composite (섬유 보강 시멘트계 복합재료의 단면 이미지에서 섬유 검출을 위한 섬유 형광 특성 분석)

  • Lee, Bang-Yeon;Park, Jun-Hyung;Kim, Yun-Yong
    • Composites Research
    • /
    • v.23 no.3
    • /
    • pp.50-57
    • /
    • 2010
  • It is important to detect fibers in the sectional image of fiber reinforced cementitious composites (FRCC), since the fiber distribution is a crucial factor to predict or evaluate the mechanical performance of FRCC. In this paper, we investigated the fluorescence characteristics of Polyvinyl Alcohol (PVA) fibers, Polyethylene Terephthalate (PET) fibers, Polyethylene (PE) fibers, and Polypropylene (PP) fibers used in Engineered Cementitious Composites (ECC), which is a special kind of FRCC that incorporates synthetic fibers and exhibits extremely ductile behavior in uniaxial tension, to detect each fiber according to its type. Furthermore, optimum excitation and emission wavelengths were proposed on the basis of maximum difference of Relative Fluorescence Intensity (RFI) between two types of fibers used in the hybrid ECC. Optimum threshold values to discriminate two types of fibers using statistical tools were also proposed. Finally, images of four types of fibers obtained using a fluorescence microscope are compared.

Genetic Analysis of Photoinhibition in Barley

  • Chun, Jong-Un
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.4
    • /
    • pp.296-302
    • /
    • 2001
  • Winter cereals are acclimated during wintering, and thereafter their freezing resistance is increased. In order to analyze inheritance and heritabilities for photoinhibition of photosynthesis by high light intensity under low temperature, and to evaluate the relationship between low temperature-induced photoinhibition and winter survival, 4 parental half diallel crosses were used. The detached leaves of 7-8cm long from plants grown for 35 and 55 days were placed on wet filter paper and placed in trays at 5$^{\circ}C$ cold room with 1,200 $\mu$mol $m^{-2}$ $s^{-1}$ PPFD. Chlorophyll fluorescence was measured with a chlorophyll fluorescence system after dark adaptation for 30 min. The Fv/Fm of 35day old plants was reduced from 0.714 in the control leaves to 0.409 and 0.368 following photoinhibitory treatment of 6h and 8h and the CVs were increased from 0.8% to 22.2-22.3%. The Fv/Fm of 55-day old plants was reduced from 0.775 in the control leaves to 0.485 and 0.439 following photoinhibitory treatment of 10h and 12h, respectively. According to half diallel cross analysis, Reno and Dongbori 1 (highly resistant to photoinhibition) was dominant, but Oweolbori (susceptible to photoinhibition) was recessive, and photoinhibition showed partial dominance with highly additive gene action. Dongbori 1 showed the greatest GCA effects for photoinhibition, and GCA/SCA ratios (8.7-22.3 times) indicated that the additive variance for the character was more important. Winter survival in barley crosses was positively correlated with resistance to photoinhibition and significantly fitted by linear regression ($R^2$=0.751$^{**}$-0.779$^{**}$). The chlorophyll fluorescence measured by Fv/Fm has been found to be highly inheritable and very useful in evaluating relative levels of freezing resistance in barley.ley.

  • PDF

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

Membrane-Ordering Effects of Barbiturates on Pure Phospholipid Model Membranes

  • Knag, Jung-Sook;Chung, Young-Za;Cho, Goon-Jae;Byun, Won-Tan;Yun, Il
    • Archives of Pharmacal Research
    • /
    • v.15 no.3
    • /
    • pp.196-203
    • /
    • 1992
  • Intramolecular excimer formation of 1, 3-di(1-pyrenyl)propane (Py-3-Py) and fluorescence polarization of 1, 6-diphenyl-1, 3, 5-hexatriene (DPH) were used to investigate the effects of barbiturates on the fluidity of model membranes of phosphatidycholine (SPMVPC), phosphatidylserine (SPMVPS), and phosphatidylinositol (SPMVPI) fractions of synaptosomal plasma membrane vesicles (SPMV) isolated from bovine cerebral cortex. In a dose-dependent manner, barbiturates decreased the excimer to monomer fluorescence intensity ratio (I'/I) of Py-3-Py and increased the anisotropy(r), rotational relaxation time (P), limiting anisotropy $(r_infty)$, and order parameter (S) of DPH in SPMVPC, SPMVPS and SPMVPI. This indicates that barbiturates decreased both the lateral and rotational diffusion of the probes in SPMVPC, SPMVPS and SPMVPI. The relative potencies of barbiturates in ordering the membranes were in the order: pentobarbital > hexobarbital > amobarbital > phenobarbital. This order correlates well with the anesthetic potencies of barbiturates and the potencies for enhancement of $\gamma$-aminobutyric acid-stimulated chloride uptake. Thus, it is strongly suggested that a close relationship might exist between the membrane ordering effects of barbiturates and the chloride fluxes across SPMV.

  • PDF

Spectrofluorimetric Determination of n-Octanol Based on its Ternary Complex with $Eu^{3+}$ and TTA ($Eu^{3+}$, TTA, 그리고 n-Octanol의 삼성분착물에 의한 n-Octanol의 분광형광분석법에 관한 연구)

  • Cha, Ki-Won;Park, Kwang-Won
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.433-438
    • /
    • 1997
  • The enhancing effect of n-octanol on the fluorescence intensity of the $Eu^{3+}$-thenoyltrifluoroacetone(TTA) system in the presence of Triton X-100 was studied using spectrofluorometric method. This complex exhibited very intense $Eu^{3+}$ ion fluorescence at 619nm, when optically excited at 345nm. Optimum conditions for the determination of n-octanol have also been investigated. The calibration graph was linear over the range $1{\times}10^{-5}M{\sim}1{\times}10^{-7}M$ and the detection limit for n-octanol is $1{\times}10^{-9}M$. The result obtained in the analysis of the synthetic sample agreed with the known value in the error range and the relative standard deviation was ca. 3.5%.

  • PDF

A Structured Growth Model of Scutellaria baicalensis G. Plant Cell (Scutellaria baicalensis G. 식물 세포의 구조적 성장 모델)

  • 최정우;조진만;이정건;이원홍;김익환;박영훈
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.251-258
    • /
    • 1998
  • A structured kinetic model is proposed to describe cell growth and secondary metabolite, flavone glycosides, synthesis in batch suspension culture of Scutellaria baicalensis G. The model has been developed by representing the physiological state of cell described as the activity and viability which can be estimated based on the culture fluorescence. In the model, three type of cells are considered; active-viable, nonactive-viable and dead cells. Viable cell weight could be determined based on the relative fluorescence intensity. The flavone glycosides could be produced by both active-viable and non-active viable cells with a different production rate. And the model includes the cell expansion due to glucose concentration and death phase which accounts for the release of intracellular secondary metabolite into medium. Dependent variables include substrate concentration(glucose), cell mass(dry cell weight and fresh cell weight), product concentration(flavone glycosides), activity and viability. Satisfactory agreement between the model and experimental data is obtained from shake flask culture of Scutellaria baicalensis G. The proposed model can predict the cell growth and flavone glycosides synthesis as well as intermediate materials.

  • PDF

Low-level Determinations of Uranium and Thorium in Geologic Samples by X-ray Fluorescence (x-선 형광분석기톨 이용한 지질시료 중 우라늄과 토륨의 미량분석)

  • Park, Yong Joon;Kim, Jung Suk;Choi, Kwang Soon;Suh, Moo Yul
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 1996
  • Trace levels of uranium and thorium in geologic samples are determined rapidly by a direct wavelength-dispersive X-ray fluorescence method. Relative intensity of scattered tube radiation was used as an internal standard to compensate for variations in instrumental operating characteristics. U and Th can be determined within a precision of ${\pm}10%$ and accuracy of ${\pm}15%$ or less with measuring times of 50 seconds for Th and 400 seconds for U, respectively. The results of XRF analysis were in good agreement with those of other methods such as nutron activation analysis and inductively coupled plasma atomic emission spectrometry.

  • PDF

Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+ (인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구)

  • Song, Dong Jin;Lee, Hyunchang
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

Temperature and Ligand Effects on the Eu(Ⅲ) Emission Spectra in the Aqueous Solution (수용액에서의 Eu(Ⅲ) 착물의 형광스펙트럼에 영향을 미치는 온도 및 리간드 효과에 관한 연구)

  • Lee, In Suk;Kim, Geon
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.548-554
    • /
    • 1990
  • Temperature effects on the fluorescence emission spectra of 0.01 M Eu(III) ion with ClO$_4$, Cl$^-$, NO$_3$ were studied. Relative intensity change of hypersensitive band ($^5D0\; {\to}\;^7F_2$) and nonhypersensitive band ($^5D0 \;{\to}\;^7F_1$) was quite remarkable with temperature and ligand. The relative intensity change was interpreted as the change of formation constant and used to calculation the enthalpy change of $Eu(H_2O)_X^{3+}$+ to EuL(H$_2O)_{X-1}^{2+}$ complex. $\Delta{H}$ of $Eu(H_2O)_X^{3+}$ to EuCl(H$_2O)_{X-1}^{2+}$ was roughly 15 kJ/mol and temperature independent, but $\Delta{H}$ of EuNO$_3(H_2O)_{X-1}^{2+}$ was changed with temperature; -11 kJ/mol at 25$^{\circ}C$ and 47 kJ/mol at 250$^{\circ}C$.

  • PDF