• Title/Summary/Keyword: reinforcing rebar

Search Result 139, Processing Time 0.019 seconds

Deterioration of GFRP rebar in alkaline solution (앙칼리 환경하에서 콘크리트 보강용 GFRP rebar의 열화현상 평가)

  • Won, Jong-Pil;Lee, Su-Jin;Jang, Chang-Il;Park, Chan-Gi;Kim, Jung-Hoon;Park, Young-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.237-240
    • /
    • 2006
  • The corrosion of steel reinforcing bar has been the major cause of the reinforced concrete deterioration. GFRP(Glass Fiber-Reinforced Polymer) reinforcing bar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. However, GFRP rebar is prone to deteriorate due to other degradation mechanisms than those for steel. The high alkalinity of concrete, for instance, is a possible degradation source. This paper presents the long-term deterioration of the GFRP rebar under alkali environmental condition.

  • PDF

Comparison of the quantity estimations from the design phase and the settlement quantities of construction field to improve the extra rates of bar splice (철근 이음조정률의 개선을 위한 설계견적 수량과 현장시공 정산 수량의 비교분석 연구)

  • Kim, Sang-Yeon;Choi, Bo-Mi
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.257-266
    • /
    • 2017
  • LH has been using ultra high strength reinforcing bars (SD500 and SD600), since 2011. Such a change requires an adjustment of the old extra rates of bar splice to reflect use of ultra high strength reinforcing bars, as these rates had been set based on SD400 bars. It is particularly difficult to calculate precisely rebar lap-splice locations for large areas, such as those in apartment buildings. This research aims to adjust the extra rates of bar splice to reflect a reasonable rate; the rebar lap-splice length is not an exact estimation, but instead, an extra rates of bar splice is set and the rebar lap-splice length is increased by 2% (D 10) - 7% (025) depending on the bar size. The subjects of this study are LH apartments undergoing frame construction. We studied the quantity estimations from the design drawings, and analyzed the settlement quantities of construction field. The results of the study revealed that, when each of the quantities are analyzed, consider adjusting the extra rates of bar splice of some rebar to 1% - 3.5%. This was caused by an overuse of reinforcing bars in onsite construction and the use of supporting bars that have not been reflected in the documents, among other reasons. Based on the results of our study, an improvement plan for the current extra rates of bar splice seems to be necessary, cutting or raising the rate depending on the analysis of the data. Through this study, we expect to contribute to the calculation of reasonable construction costs, improvements in the quality of rebar work, and improvements in the capacity of design techniques for apartment buildings.

A Study on the Characteristics of Reinforcing Steel according to Specification and Diameter (철근의 강종 및 직경 변화에 따른 부식특성에 관한 연구)

  • Lim, Jae-won;Jee, Nam-Yong;Yoon, Sang-Chun;Choi, Jin-man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.53-58
    • /
    • 2003
  • Concrete structures move wholly with concrete and rebar, so they endure external force, but recently the embedded rebar in concrete has been corroded by environmental, physical and chemical factors, the embedded rebar corrosion influences concrete structure to deteriorate structure capacity. To revaluate effect to deterioration of concrete structure according to corrosion of rebar, the researcher mostly examined into corrosion rebar and complex relation of concrete. In that there are flexural strength deterioration of corrosion concrete structure and the bond strength of concrete. But It has not sufficiently studied about physical characteristic of corrosion rebar itself. In this study I will compare specification of rebar through corrosion experiment with corrosion ratio of rebar according to diameter and revaluate. And will investigate the effect to strength characteristic of rebar according to corrosion ratio.

  • PDF

A Study on the Characteristics of Reinforcing Steel according to Specification and Diameter (철근의 강종 및 직경 변화에 따른 부식특성에 관한 연구)

  • 임재원;지남용;윤상천;최진만
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.53-58
    • /
    • 2003
  • Concrete structures move wholly with concrete and rebar, so they endure external force, but recently the embedded rebar in concrete has been corroded by environmental, physical and chemical factors. the embedded rebar corrosion influences concrete structure to deteriorate structure capacity. To revaluate effect to deterioration of concrete structure according to corrosion of rebar, the researcher mostly examined into corrosion rebar and complex relation of concrete. In that there are flexural strength deterioration of corrosion concrete structure and the bond strength of concrete. But It has not sufficiently studied about physical characteristic of corrosion rebar itself. In this study I will compare specification of rebar through corrosion experiment with corrosion ratio of rebar according to diameter and revaluate. And I will investigate the effect to strength characteristic of rebar according to corrosion ratio.

  • PDF

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

Mechanical Properties of Hybrid FRP Rebar (하이브리드 FRP 리바의 역학적 특성)

  • 박찬기;원종필
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

A Basic Study of Automatic Rebar Length Estimate Algorithm of Columns by Using BIM-Based Shape Codes Built in Revit (BIM 기반 형상코드를 이용한 기둥 철근길이 자동 산정 기초 연구)

  • Oh, Jin-Hyuk;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.21-22
    • /
    • 2023
  • In reinforced concrete constructions, reinforcing bar generates more CO2 per unit weight than other construction materials. In particular, cutting and bending rebar is the main source of rebar waste in the construction industry. Rebar-cutting waste is inevitable during the construction of a reinforced concrete structure since the rebar is not manufactured as designed. Large amounts of waste can be avoided by utilizing optimal cutting patterns and schedules. This research provides a fundamental analysis of the automatic calculation of column rebar length using BIM-based shape codes to minimize cutting waste to near zero. By employing this approach in practice, it is possible to minimize the rate of rebar-cutting waste, reduce costs, shorten construction duration, and reduce CO2 emissions. In addition, the development of this research will serve as a clue for the development of BIM-based rebar layout automation algorithms.

  • PDF

Enhancements in Performance and Manufacturing Efficiencies of GFRP Rebar (GFRP 보강근의 성능 및 제작 효율화 방안)

  • You, Young Jun;Kim, Jang Ho;Park, Young Hwan;Park, Ji Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.110-119
    • /
    • 2012
  • Fiber reinforced polymer (FRP) reinforcing rebar with non-corrosive property is suggested as an alternative replacement to steel reinforcing rebar due to its enhanced durability and non-corrosive characteristics. Currently, a limited number of glass fiber reinforced polymer rebar (GFRP) are sold commercially due to their high cost, relatively low performances, and brittle failure characteristics. Therefore, the performance enhancements and cost reduction of GFRP rebar are needed to increase its applications in construction fields. The intent of this study is to develop high performance GFRP rebar by improving its tensile and shear properties. Also, in order to reduce manufacturing costs, factors such as material composition and manufacturing process were evaluated to improve manufacturing efficiency. Finally a GFRP rebar with enhanced material properties and less expensive than the GFRP rebar currently sold in the market was manufactured and evaluated for its application possibility in construction fields.

A Study on the Surface Roughness of Corroded Reinforcing Rebar (부식된 철근의 표면 거칠기에 관한 연구)

  • Roh, Young-Sook;Lee, Sun-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.78-83
    • /
    • 2010
  • This paper discusses the surface roughness of corroded reinforcement rebar in reinforced concrete structures focusing on the quantitative measurement technique for rebar corrosion. Reinforcement rebar was corroded using accelerated corrosion induced method and corrosion rates were 0%, 1%, 2%, 3%, 5%, and 10% of mass losses. Using 3-dimensional scanner each surface profile of reinforcement rebar was established, and surface roughness was measured. Through tests and analyses of corroded reinforcement rebar, the following topics were particularly discussed: measurement of surface roughness, relationship between area and surface roughness, relationship between surface roughness and bond performance. As a result, surface roughness of corroded rebar was found to be very effective to bond strength until 2% of corrosion rate. It was also discussed how to relate surface roughness of corroded rebar to bond strength of reinforced concrete structures.

A Study on the Improvement of Reinforcing Bar Detailing (국내 철근공사 배근상세 개선방안에 관한 연구)

  • Park, U-Yeol;Kim, Baek-Jung;Jung, Hyun-Ok;Yun, Seok-Heon;Cho, Hun-Hee;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.83-90
    • /
    • 2008
  • The reinforcing steel process is composed of the development of placing drawing, cutting and bending, and the placement and fabrication of the reinforcement, and is participated in by reinforcement detailer, the fabricator and placer. Because the reinforcing steel process-from estimating and rebar detailing, to production, material tracking, billing, and general accounting-is conducted by many participant, reinforcement details based on building code and reinforcing bar detailing standards are essential. The process, however, holds some problems. Building code has been revised recently, and the utilization of placing drawings was proved to be low, and the reinforcement estimating in early stage of the process is below what is required for placement. Therefore, in this study, a survey was conducted to the reinforcement detailer, the fabricator and placer of domestic construction industry. According to the analysis of the survey, the reinforcement details on site was not standardized. The improvement in reinforcing steel detailing standards was sought by analyzing the results of the survey including reinforcement constructability.