• Title/Summary/Keyword: reinforced technique

Search Result 870, Processing Time 0.02 seconds

Strain monitoring of reinforced concrete with OTDR-based FBG interrogation technique

  • Dyshlyuk, Anton V.;Makarova, Natalia V.;Vitrik, Oleg B.;Kulchin, Yuri N.;Babin, Sergey A.
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.343-350
    • /
    • 2017
  • An experimental study is presented of the application of fiber Bragg grating (FBG) interrogation method based on optical time-domain reflectometery (OTDR) to monitoring strain in bent reinforced concrete beams. The results obtained with the OTDR-based method are shown to agree well with the direct spectral measurements. Strain sensitivity, resolution and measurement range amounted to $0.0028dB/{\mu}strain$; $30{\mu}strain$; $4000{\mu}strain$, correspondingly. Significant differences are observed in surface and inner deformations of the test beams which can be attributed to different mechanical properties of concrete and steel reinforcement. The prospects of using OTDR-based FBG interrogation technique in real-life applications are discussed.

Acoustic Emission Technique for Crack Source Location of Reinforced Concrete Beams Strengthened in Shear with CFRP (CFRP로 전단보강된 철근콘크리트 보에서 음향방출 특성을 이용한 균열 위치추정)

  • Lee, Young-Oh;Kim, Sun-Woo;Yun, Hyun-Do;Seo, Soo-Yeon;Choi, Chang-Sik;Choi, Ki-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.322-325
    • /
    • 2006
  • This study was conducted to develop the crack location technique for CFRP reinforced concrete beam using AE method. To experimentally prove the crack source location made of four reinforced concrete beams strengthened in shear with CFRP. The results compared the real cracking location with the source location has perceived by AE monitoring, before it is appeared the primary crack by visual observation. So, This study used by a basic data in constructing the system of the failure warning at application.

  • PDF

A technique for optimally designing fibre-reinforced laminated structures for minimum weight with manufacturing uncertainties accounted for

  • Walker, M.
    • Steel and Composite Structures
    • /
    • v.7 no.3
    • /
    • pp.253-262
    • /
    • 2007
  • A methodology to design symmetrically laminated fibre-reinforced structures under transverse loads for minimum weight, with manufacturing uncertainty in the ply angle, is described. The ply angle and the ply thickness are the design variables, and the Tsai-Wu failure criteria is the design constraint implemented. It is assumed that the probability of any tolerance value occurring within the tolerance band, compared with any other, is equal, and thus the approach is a worst-case scenario approach. The finite element method, based on Mindlin plate and shell theory, is implemented, and thus effects like bending-twisting coupling are accounted for. The Golden Section method is used as the search algorithm, but the methodology is flexible enough to allow any appropriate finite element formulation, search algorithm and failure criterion to be substituted. In order to demonstrate the procedure, laminated plates with varying aspect ratios and boundary conditions are optimally designed and compared.

DURABILITY TESTING OF MARINE REINFORCED CONCRETE UNDER FATIGUE LOADING, PART I AND II (피로하중을 받는 해양 콘크리트의 내구성 연구)

  • ;D. V. Reddy
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.348-353
    • /
    • 1996
  • This study addresses the evaluation of the durability of reinforced concrete marine structures subjected to fatigue loading. The laboratory investigation was carried out on full and half size reinforced concrete specimens with three different water cement ratios (0.3, 0.4, and 0.56), static and fatigue loading conditions, and epoxy-coated and regular black steel reinforcements. The marine tidal zone was simulated by alternate filling and draining of the tank (wet and dry cycled), and a galvanostatic corrosion technique to accelerate corrosion of reinforcement was used. Half-cell potentials and changes of crack width were measured periodically during the exposure and followed by ultimate strength testing. The significant findings include adverse effect of fatigue loading, existence of an explicit size effect, poor performance of epoxy coated steel, and negative effect of increasing water/cement ratio.

  • PDF

A new SDOF method of one-way reinforced concrete slab under non-uniform blast loading

  • Wang, Wei;Zhang, Duo;Lu, Fangyun;Liu, Ruichao
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.595-613
    • /
    • 2013
  • A new effective model for calculation of the equivalent uniform blast load for non-uniform blast load such as close-in explosion of a one-way square and rectangle reinforced concrete slab is proposed in this paper. The model is then validated using single degree of freedom (SDOF) system with the experiments and blast tests for square slabs and rectangle slabs. Test results showed that the model is accurate in predicting the damage level on the tested RC slabs under the given explosive charge weight and stand-off distance especially for close-in blast load. The results are also compared with those obtained by conventional SDOF analysis and finite element (FE) analysis using solid elements. It is shown that the new model is more accurate than the conventional SDOF analysis and is running faster than the FE analysis.

Reinforced high-strength concrete square columns confined by aramid FRP jackets -part I: experimental study

  • Wang, Yuan-Feng;Ma, Yi-Shuo;Wu, Han-Liang
    • Steel and Composite Structures
    • /
    • v.11 no.6
    • /
    • pp.455-468
    • /
    • 2011
  • Although retrofitting and strengthening reinforced concrete (RC) columns by wrapping fiber reinforced polymer (FRP) composites have become a popular technique in civil engineering, the study on reinforced high-strength concrete (HSC) columns is still not sufficient. The objective of these companion papers is to investigate the mechanical properties of reinforced HSC square columns confined by aramid FRP (AFRP) jackets under concentric compressive loading. In the part I of these companion papers, an experiment was conducted on 54 confined RC specimens and nine unconfined plain specimens, the considered parameters were the concrete strength, the thickness of AFRP jackets, and the form of AFRP wrapping. The experimental process and results are presented in detail. Subsequently, some discussions on the confinement effect, failure modes, strength, and ductility of the columns are carried out.

A Parametric Study on the Loading Rate Sensitivity of R/C Element Behavior (R/C 부재의 하중재하속도 변화에 따른 민감성 연구)

  • 심종성
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.04a
    • /
    • pp.38-43
    • /
    • 1989
  • An improved model for predicting the reinforced concrete element behavior under dynamic strain rates was developed using the layer modeling technique. The developed strain rate sensitive model for axial/flexural analysis of reinforced concrete elements was uses to predict the test results, performed at different loading rates, and the predictions were reasonable. The developed analysis technique was used to study the loading rate sensitivity of reinforced concrete beams and columns with different geometry and material properties. Two design formulas for computing the loading rate dependent axial and flexural strengths of reinforced concrete sections were also suggested.

  • PDF

Experimental study on acoustic emission characteristics of reinforced concrete components

  • Gu, Aijun;Luo, Ying;Xu, Baiqiang
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.67-79
    • /
    • 2015
  • Acoustic emission analysis is an effective technique for monitoring the evolution of damage in a structure. An experimental analysis on a set of reinforced concrete beams under flexural loading was carried out. A mixed AE analysis method which used both parameter-based and signal-based techniques was presented to characterize and identify different failure mechanisms of damage, where the signal-based analysis was performed by using the Hilbert-Huang transform. The maximum instantaneous energy of typical damage events and the corresponding frequency characteristics were established, which provided a quantitative assessment of reinforced concrete beam using AE technique. In the bending tests, a "pitch-catch" system was mounted on a steel bar to assess bonding state of the steel bar in concrete. To better understand the AE behavior of bond-slip damage between steel bar and concrete, a special bond-slip test called pullout test was also performed. The results provided the basis of quantitative AE to identify both failure mechanisms and level of damages of civil engineering structures.

Bioblock technique to treat severe internal resorption with subsequent periapical pathology: a case report

  • Mark Frater;Tekla Sary;Sufyan Garoushi
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.43.1-43.9
    • /
    • 2020
  • A variety of therapeutic modalities can be used for the endodontic treatment of a traumatized tooth with internal root resorption (IRR). The authors present a case report of the successful restoration of a traumatized upper central incisor that was weakened due to severe IRR and subsequent periapical lesion formation. A 20-year-old female patient was referred to our clinic with severe internal resorption and subsequent periapical pathosis destroying the buccal bone wall. Root canal treatment had been initiated previously at another dental practice, but at that time, the patient's condition could not be managed even with several treatments. After cone-beam computed tomography imaging and proper chemomechanical cleaning, the tooth was managed with a mineral trioxide aggregate plug followed by root canal filling using short fiber-reinforced composite, known as the Bioblock technique. This report is the first documentation of the use of the Bioblock technique in the restoration of a traumatized tooth. The Bioblock technique appears to be ideal for restoring wide irregular root canals, as in cases of severe internal resorption, because it can uniquely fill out the hollow irregularities of the canal. However, further long-term clinical investigations are required to provide additional information about this new technique.

Evaluation & Development of Strengthening Method by External Post-tension (외부 포스트텐션 보강공법의 개발 및 평가)

  • Lim, Jae-Hyung;Moon, Jeong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.91-100
    • /
    • 2008
  • A technique strengthened to the reinforced concrete members using the external post- tensioned method offers the advantages in speed and simplicity of installation over other, established, strengthening techniques. But this technique has many unreasonable facts. This paper are analyzed an unreasonable facts of the previous external post-tension technique. The purpose of this paper proposed Bow system as the new technique strengthened to the reinforced concrete members. The Bow system which is better technique than the previous technique was introduced with the experimental/analytical data.