• Title/Summary/Keyword: reinforced buildings

Search Result 835, Processing Time 0.027 seconds

Lessons learned from recent destructive Van, Turkey earthquakes

  • Yon, Burak;Sayin, Erkut;Calayir, Yusuf;Ulucan, Zulfu Cinar;Karatas, Mehmet;Sahin, Humeyra;Alyamac, Kursat Esat;Bildik, Abdullah Tevfik
    • Earthquakes and Structures
    • /
    • v.9 no.2
    • /
    • pp.431-453
    • /
    • 2015
  • A destructive earthquake, the magnitude of this earthquake was 7.2, hit Van, Turkey on October 23, 2011. After this devastating earthquake, a moderate earthquake which had 5.7 magnitude on November 9, 2011 occurred in Edremit, Van. These earthquakes caused heavy damages and collapses in many reinforced concrete buildings with loss of lives. In this paper, characteristics of ground motions of these earthquakes were studied and, deficiencies in structural elements and engineering faults such as poor workmanship and quality of construction, soft and weak stories, strong beam-weak column, short column, large overhang, hammering and unconfined gable wall were investigated. According to the observations, it was seen that, low quality of structural materials, lack of engineering services, inappropriate design and construction with insufficient detailing of the structural elements were the main reasons of heavy damages.

Shear strength analysis and prediction of reinforced concrete transfer beams in high-rise buildings

  • Londhe, R.S.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.1
    • /
    • pp.39-59
    • /
    • 2011
  • Results of an experimental investigation on the behavior and ultimate shear capacity of 27 reinforced concrete Transfer (deep) beams are summarized. The main variables were percent longitudinal(tension) steel (0.28 to 0.60%), percent horizontal web steel (0.60 to 2.40%), percent vertical steel (0.50to 2.25%), percent orthogonal web steel, shear span-to-depth ratio (1.10 to 3.20) and cube concrete compressive strength (32 MPa to 48 MPa).The span of the beam has been kept constant at 1000 mm with100 mm overhang on either side of the supports. The result of this study shows that the load transfer capacity of transfer (deep) beam with distributed longitudinal reinforcement is increased significantly. Also, the vertical shear reinforcement is more effective than the horizontal reinforcement in increasing the shear capacity as well as to transform the brittle mode of failure in to the ductile mode of failure. It has been observed that the orthogonal web reinforcement is highly influencing parameter to generate the shear capacity of transfer beams as well as its failure modes. Moreover, the results from the experiments have been processed suitably and presented an analytical model for design of transfer beams in high-rise buildings for estimating the shear capacity of beams.

Efficient damage assessment for selected earthquake records based on spectral matching

  • Strukar, Kristina;Sipos, Tanja Kalman;Jelec, Mario;Hadzima-Nyarko, Marijana
    • Earthquakes and Structures
    • /
    • v.17 no.3
    • /
    • pp.271-282
    • /
    • 2019
  • Knowing the response of buildings to earthquakes is very important in order to ensure that a structure is able to withstand a given level of ground shaking. Thus, nonlinear dynamic earthquake engineering analyses are unavoidable and are preferable procedure in the seismic assessment of buildings. In order to estimate seismic performance on the basis of the hazard at the site where the structure is located, the selection of appropriate seismic input is known to be a critical step while performing this kind of analysis. In this paper, seismic analysis is performed for a four-story reinforced concrete ISPRA frame structure which is designed according to Eurocode 8 (EC8). A total of 90 different earthquake scenarios were selected, 30 for each of three target spectrums, EC8 spectrum, Uniform Hazard Spectrum (UHS), and Conditional Mean Spectrum (CMS). The aim of this analysis was to evaluate the average maximum Inter-story Drift Ratio (IDR) for each target spectrum. Time history analysis for every earthquake record was obtained and, as a result, IDR as the main measure of damage were presented in order to compare with defined performance levels of reinforced concrete bare frames.

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador;Oh, Sang-Hoon;Shin, Seung-Hoon
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1107-1124
    • /
    • 2018
  • The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method (격자형 유닛 상세를 가진 단면증설공법으로 보강된 철근콘크리트 기둥의 구조성능평가)

  • Moon, Hong Bi;Lee, Jeong In;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.

Seismic performance improvement of RC buildings with external steel frames

  • Ecemis, Ali Serdar;Korkmaz, Hasan Husnu;Dere, Yunus
    • Computers and Concrete
    • /
    • v.27 no.4
    • /
    • pp.343-353
    • /
    • 2021
  • In this study, in order to improve the seismic performance of existing reinforced concrete (RC) framed structures, various external attachment of corner steel frame configurations was considered as a user-friendly retrofitting method. The external steel frame is designed to contribute to the lateral stiffness and load carrying capacity of the existing RC structure. A six-story building was taken into account. Four different external corner steel frame configurations were suggested in order to strengthen the building. The 3D models of the building with suggested retrofitting steel frames were developed within ABAQUS environment using solid finite elements and analyzed under horizontal loadings nonlinearly. Horizontal top displacement vs loading curves were obtained to determine the overall performance of the building. Contributions of steel and RC frames to the carried loads were computed individually. Load/capacity ratios for the ground floor columns were presented. In the study, 3D rendered images of the building with the suggested retrofits are created to better visualize the real effect of the retrofit on the final appearance of the façade of the building. The analysis results have shown that the proposed external steel frame retrofit configurations increased the lateral load carrying capacity and lateral stiffness and can be used to improve the seismic performance of RC framed buildings.

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

Demand Strength Spectrums of Low-Rise Reinforced Concrete Buildings Consisted of Extremely Brittle, Shear and Flexural Failure Systems (극취성·전단·휨파괴형 수평저항시스템으로 구성된 저층 철근콘크리트 건물의 요구 내력 스펙트럼)

  • Lee, Kang-Seok;Kim, Jeong-Hee;Oh, Jae-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.529-537
    • /
    • 2007
  • The purpose of this study is to discuss how strength and ductility of each system in low-rise reinforced concrete buildings composed of extremely brittle, shear and flexural failure lateral-load resisting systems have influence on seismic capacities of the overall system, which is based on nonlinear seismic response analyses of single-degree-of-freedom structural systems. In order to simulate the triple lateral-load resisting system, structures are idealized as a parallel combination of two modified origin-oriented hysteretic models and a degrading trilinear hysteretic model that fail primarily in extremely brittle, shear and flexure, respectively. Stiffness properties of three models are varied in terms of story shear coefficients, and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of demand strengths of the triple system for various levels of ductility factors are finally derived for practical purposes. The result indicates that demand strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete buildings having the triple lateral-load resisting system.

Nonlinear Seismic Analysis Method of Reinforced Concrete Buildings Including Their Pile Foundations (말뚝기초를 포함한 철근콘크리트 건물의 비선형 지진해석법에 관한 연구)

  • 이강석;이원호;류해상
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.9-20
    • /
    • 2003
  • At present, the information on the foundation-structure interaction is lacking. As a result, the seismic performance evaluation of buildings seldom considers the effect of the foundation performance on the building responses. Recent earthquakes such as the 1993 Hokkaido Nansei-oki Earthquake(M=7.8), the 1994 Northridge Earthquake(M=6.7), the 1995 Hyogoken-Nambu Earthquake(M=7.2), and the 1999 Chi-Chi Earthquake (M=7.6) have shown that building damages are significantly affected by the degree of damage sustained by the building foundation and the interaction between the building and the foundation. This paper presents a nonlinear seismic analysis method for the seismic performance evaluation of reinforced concrete buildings which considers the pile foundation-structure interaction. The proposed method is applied to an actual building which was damaged during the 1993 Hokkaido Nansei-oki Earthquake. The result reveal that the method is able to predict the performance of the building.

A Study on Characteristics of the Modern Warehouse in Gunsan and Its Value as Industrial Heritage (군산의 근대 창고건물 현황 및 산업유산으로서의 가치에 관한 연구)

  • Pak, Sung-Sine
    • Journal of architectural history
    • /
    • v.20 no.6
    • /
    • pp.21-39
    • /
    • 2011
  • This research is to analyze the modern warehouses in Gunsan during the Japanese Colonial Period. They were the spatial and urban symbol of City of Rice, Gunsan. The main purpose of this study is to survey the modern warehouses in the original center of city, to find their architectural characteristics and to set up a possibility of reuse. 7 existing warehouse buildings are located at Jangmi-Dong and Jooksung-Dong, and they have been built between 1935 and 1940. The warehouse buildings have a module of 6m and they are generally 12m wide, 24~48m long and 8m high. Their structure is composed of reinforced concrete and wooden truss. All warehouse buildings have a rectangular form. Now the diverse commercial programs occupy the original space. Modern warehouse in Gunsan has the spatial and symbolic value as industrial heritage. Therefore, it is necessary to respect the original value of modern warehouse and to create a reusing space for the current generation. It is also essential to verify restoring possibility of three symbolic warehouse buildings in the harbour that were demolished.