• 제목/요약/키워드: reinforced beam-column joint

검색결과 239건 처리시간 0.021초

External retrofit of beam-column joints in old fashioned RC structures

  • Adibi, Mahdi;Marefat, Mohammad S.;Arani, Kamyar Karbasi;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.237-250
    • /
    • 2017
  • There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.

철근콘크리트기둥과 철골보 접합부의 휨성능(1) (A Structural Flexible Behavior T-type Joint for RCS Composite System)

  • 김영수;김영호;정재훈;김진무;원영술;주경재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.139-146
    • /
    • 2001
  • Res system, with Reinforced Concrete columns and Steel beams, is defined as system in which both steel and concrete materials are efficiently combined to maximize the structural and economic advantages of each material. Tested in this study were 4 exterior beam-to-column joint specimens with variables that influence joint rigidity of RCS structure. The purpose of this study is to compare and analyze the structural behavior of exterior joints through the existing studies and tests, and offer basic data for practical use of RCS structure by studying flexible behavior(semi-rigid effect) of joints according to joint details.

  • PDF

고장력 철근이 적용된 철근콘크리트 보-기둥 접합부 파괴모드에 대한 실험적 연구 (Experimental Study on Seismic Performance of Beam-column Connections with High Strength Reinforcements)

  • 김대훈;박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2016
  • Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix II. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.

강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능에 대한 실험적 연구 (An Experimental Study on the Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint with Steel Fiber Volume Fractions)

  • 이장재;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.15-23
    • /
    • 2018
  • The purpose of this study is to evaluate the anchorage capacity of longitudinal bars for reinforced concrete exterior beam - column joints with steel fiber volume fractions. For this purpose, the steel fiber volume fraction was set to 0, 1, 2%, and the performance was compared with that of each other specimens. According to the test results, the maximum strength of EX-HK-NJR-0 decreased by 13% compared with the control specimen and EX-HK-NJR-1 decreased by 3% compared to the control specimen. However, when 2% of steel fiber was mixed, the maximum strength increased about 56% compared to the control specimen. The energy dissipation capacity of EX-HK-NJR-0 (when no transverse steel bars are placed) decreased by 61% compared to the control specimen. In addition, the energy dissipation capacity of the specimens with a steel fiber content of 1% decreased by 5% and 2% increased by 94% compared to control specimen. EX-HK-NJR-1,2 and the control specimen EX-HK-JR-0 experienced yielding of the reinforcing bars at the column interface before maximum strength development. However, when the EX-HK-NJR-0, the reinforcing bars at the column interface experienced yielding after maximum strength development. Therefore, reinforcement of steel fiber is considered to reduce the required development length for yielding of steel bars.

Experimental Cyclic Behavior of Precast Hybrid Beam-Column Connections with Welded Components

  • Girgin, Sadik Can;Misir, Ibrahim Serkan;Kahraman, Serap
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.229-245
    • /
    • 2017
  • Post-earthquake observations revealed that seismic performance of beam-column connections in precast concrete structures affect the overall response extensively. Seismic design of precast reinforced concrete structures requires improved beam-column connections to transfer reversed load effects between structural elements. In Turkey, hybrid beam-column connections with welded components have been applied extensively in precast concrete industry for decades. Beam bottom longitudinal rebars are welded to beam end plates while top longitudinal rebars are placed to designated gaps in joint panels before casting of topping concrete in this type of connections. The paper presents the major findings of an experimental test programme including one monolithic and five precast hybrid half scale specimens representing interior beam-column connections of a moment frame of high ductility level. The required welding area between beam bottom longitudinal rebars and beam-end plates were calculated based on welding coefficients considered as a test parameter. It is observed that the maximum strain developed in the beam bottom flexural reinforcement plays an important role in the overall behavior of the connections. Two additional specimens which include unbonded lengths on the longitudinal rebars to reduce that strain demands were also tested. Strength, stiffness and energy dissipation characteristics of test specimens were investigated with respect to test variables. Seismic performances of test specimens were evaluated by obtaining damage indices.

다이아프램이 없는 콘크리트 충전 원형강관 기둥-H형강 보 접합부의 구조적 거동에 관한 실험적 연구 (Experimental Study on the Structural Behavior of Concrete-Filled Circular Tubular Column to H-Beam connections without Diaphragm)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제9권1호통권30호
    • /
    • pp.13-22
    • /
    • 1997
  • This paper is concerned with an experimental study on structural behavior of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections. The important parameters are the number of inner reinforced rib and the width of H-beam flange(100, 150, 200mm) with variable column thickness(5.8mm, 9.2mm, 12.5mm) around the joint between CFCT and H-beam. Test results are summarized for the displacement, strength, initial stiffness, failure mode and energy absorption capacity of each specimen. The purpose of this paper is to investigate the initial stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections. From the discussion about the test results, the basic data for non diaphragm connection design would be suggested.

  • PDF

철근콘크리트 보-기둥 접합부의 연성능력 (Deformability of RC Beam-Column Assembles)

  • 이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.193-196
    • /
    • 2008
  • 이 연구에서는 지진하중을 받는 철근콘크리트 보-기둥 접합부의 연성능력을 평가하였다. 철근콘크리트 보-기둥 접합부 설계는 보에 소성힌지가 발생하기 이전에 접합부가 파괴하는 경우와 보에 소성힌지가 발생한 이후에 접합부 또는 보가 파괴하는 경우로 구분하여 설계하고 있다. 지금까지의 대부분의 기존 연구는 접합부의 강도 평가에 중점을 두고 있으며, 접합부의 연성능력 평가에 대한 연구는 미흡한 실정이다. 이 연구에서는 접합부의 연성을 기둥, 보, 접합부 패널 부분으로 구분하여 각각의 부재가 보-기둥 접합부의 전체 연성에 미치는 영향을 평가하였다. 접합부 설계는 일반적으로 보에 소성힌지를 발생시키고 접합부를 포함한 기둥은 탄성 상태로 설계하므로 탄성해석에 의하여 기둥의 연성을 평가하였다. 접합부 패널은 보의 소성힌지의 변형에 의하여 영향을 받게 된다. 따라서 이 연구에서는 보의 소성힌지의 영향을 고려한 접합부 패널 연성을 평가하였다. 소성힌지가 발생한 보의 연성은 보-기둥 접합부의 연성능력에 가장 큰 영향을 미친다. 보의 연성은 보의 휨에 의한 영향, 철근의 뽑힘에 의한 영향, 소성힌지 구역의 축방향 변형률 증대에 의한 영향으로 구분하였다. 또한 접합부의 부착강도 저감 및 보의 주철근 항복 이후의 철근의 뽑힘 및 소성힌지 구역의 축방향 변형률 증대에 의한 영향을 고려하여 보의 연성능력을 평가하였다.

  • PDF

비내진 상세를 가진 RC 보-기둥 접합부의 지진 거동 (Seismic Behavior of Nonseismically Detailed Reinforced Concrete Beam-Column Joints)

  • 우성우;이한선
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.894-901
    • /
    • 2003
  • 본 연구의 목적은 비내진 상세를 가진 RC 구조물의 이력거동 특성과 내진성능 및 특성을 알아보기 위한 것이다. 이를 위해 10층 RC구조물의 내 외부 접합부를 선정하여 슬래브의 유무, 접합부내에서의 전단철근 유무, 외부 접합부의 보 하부 주근의 정착방향에 따라 6개의 1/3 축소 실험체를 만들어 반복횡하중 실험을 수행하였다. 실험결과 내부 접합부의 경우 슬래브의 유무에 관계없이 내진 비내진 상세의 상이에 따른 강도나 연성 능력의 변화는 크지 않는 것으로 나타났고, 외부 접합부의 경우 내부 접합부와는 달리 접합부 전단 보강근의 유무뿐만 아니라 하단 주철근 정착방향에서도 차이가 나기 때문에 비내진 상세의 강도나 연성 능력이 각각 10∼20%와 27% 정도 작은 것으로 나타났다. 또, 비내진 상세를 가지는 경우 국부 변형이 한 곳에서 집중되어 크게 나타남을 알 수 있으며, 슬래브가 있음으로 인해 휨에 의한 회전각을 억제하고 상향 전단변형을 억제하는 것으로 나타났다. 한편 보-기둥 접합부에서의 전단 보강근은 전단변형률에 거의 영향을 끼치지 않는 것으로 나타났다.

고강도 RC 보-기둥 접합부의 비탄성 거동에 대한 슬래브의 영향 (Slab Effect on Inelastic Behaviors of High Strength RC Beam-Column Joints)

  • 장극관;김윤일;오영훈
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.167-177
    • /
    • 1997
  • 모멘트 연성골조의 접합부와 기둥은 적절한 에너지흡수 능력과 구조물의 횡붕괴를 방지하기 위하여 탄성적으로 거동해야 하며, "강한 기둥-약한 보"의 설계개념을 채택하고 있다. 접합부는 골조구조의 취약부분으로 인정되고 있지만 부재설계에서는 접합부를 구성하는 보와 기둥에 의해서 접합부의 치수가 결정되기 때문에 접합부가 부담해야 하는 하중조건과 보강방법을 결정하는데에 어려움이 있다. 또한 콘크리트의 고강도화, 경량화에 의해 부재단면은 작아지게 되고 상대적으로 철근량은 늘어나게 되므로 접합부 영역의 응력부담은 이전보다 훨씬 높아지게 되었다. 따라서 접합부의 적절한 구조성능 확보 및 시공상의 문제점을 개선하기 위하여 접합부의 설계 및 상세에 특별한 주의가 필요하다고 할 수 있다. 이에 본 연구에서는 슬래브의 기여도를 고려한 접합부의 적절한 보강방법을 제시하기 위한 기초자료로서 $\frac{2}{3}$의 실물크기로 4개의 고강도 콘크리트 보-기둥 접합부를 제작하고, 반복하중 실험을 수행하였다.실험을 수행하였다.

혼합구조로 이루어진 보-기둥 접합부의 구조적 거동 특성 (The Properties for Structural Behavior of Beam-Column Joint Consisting of Composite Structure)

  • 이승조;박정민;김화중
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.445-455
    • /
    • 2000
  • 본 연구는 최근의 건설 환경 변화에 따른 여러 가지 제문제점들에 대한 구조적 측면에서의 대응책의 하나로서 새로운 구조 시스템 전개를 위해 이종구조부재로 구성된 보기둥 접합부 모델을 제안한 것이다. 본 연구에서는 장스팬 S보의 강성을 향상시키기 위해 S조의 단부를 RC조로 보강하여 강성 및 내력증대를 꾀하였으며, 이종구조 사이의 원활한 응력 전달을 목적으로 SRC조 단부의 보 주근은 U자형 갈고리 모양으로 정착하여 철골 플랜지에 용접 접합하였다. 일련의 실험을 통해 접합부 강성 및 내력 특성을 고찰하였고 본 접합부의 가능성을 제시하였다.

  • PDF