• Title/Summary/Keyword: regression lines

Search Result 230, Processing Time 0.021 seconds

A Study of Impact Factors and Barrier Height of Compact Car Road for Decision of Barrier Type (소형차도로 방호울타리 형식선정을 위한 충돌계수 및 방호울타리 높이선정 연구)

  • Choi, Hyun-Ho;Kim, Ki-Hwan;Lee, Eui-Joon;Yi, Sang-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6D
    • /
    • pp.605-613
    • /
    • 2010
  • In this study, Impact factors are represented and barrier height of compact car road of safety barrier is suggested through the investigation of applying problems of existed standard of general car road. For this, traffic accidents analysis is performed and based on the analysis, impact vehicle weight, impact Angle, crash velocity, and barrier height are investigated. For the decision of impact angle, analysis is carried out by comparison of RISER and 2-lines expressway accidents data. Through this, higher-impact angle is suggested. Vehicle weight data of sub-compact car, small vehicle, medium and large vehicle, SUV, small truck is surveyed and analyzed. Based on the accident accumulation rate, regression analysis of vehicle weight impact and impact velocity is performed. Also, based on the cumulative rate of vehicle weight on expressways near Seoul, barrier height of compact car road is calculated. It is noted that the results of this study will be contributed to the decision of barrier type.

A Study on the Road Safety Analysis Model: Focused on National Highway Areas in Cheonbuk Province (도로 안전성 분석 모형에 관한 연구: 전라북도 국도 권역을 중심으로)

  • Lim, Joonbeom;Kim, Joon-Ki;Lee, Soobeom;Kim, Hyunjin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.583-595
    • /
    • 2014
  • Currently, Korean transportation policies are aiming for increase of safety and environment-friendly and efficient operation, by avoiding construction and expansion of roads, and upgrading road alignments and facilities. This is revealed by that there have been 22 road expansion projects (30%) and 50 road improvement projects (70%) under the 3rd Five-Year Plan for National Highways ('11~'15), while there were 53 road expansion projects (71%) and 22 road improvement projects (29%) under the 2nd Five-Year Plan for National Highways. For more effective road improvement projects, there is a need of choosing projects after an objective and scientific safety assessment of each road, and assessing safety improvement depending on projects. This study is intended to develop a model for this road safety analysis and assessment. The major objective of this study is creating a road safety analysis and assessment model appropriate for Korean society, based on the HSM (Highway Safety Manual) of the U.S. In order to build up data for model development, the sections thought to have identical geometrical structure factors in 5 lines, Cheonbuk province, were divided as homogeneous sections, and representative values of geometric structures, facilities, traffic volume, climate conditions and land usage were collected from the 1,452 sections divided. In order to build up data for model development, the sections thought to have identical geometrical structure factors in 5 lines, Cheonbuk province, were divided as homogeneous sections, and representative values of geometric structures, facilities, traffic volume, climate conditions and land usage were collected from the 1,452 sections divided. The collected data was processed correlation analysis of each road element was implemented to see which factor had a big effect on traffic accidents. On the basis of these results, then, an accident model was established as a negative binomial regression model.Using the developed model, an Crash Modification Factor (CMF) which determines accident frequency changes depending on safety performance function (SPF) predicting the number of accident occurrence through traffic volume and road section expansion, road geometric structure and traffic properties, was extracted.

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Studies on the growth duration and hybrid sterility in remote cross breeding of cultivated rice (수도원연품종간잡종에 있어서의 생육일수와 불임에 관한 연구)

  • Mun-Hue Heu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.4 no.1
    • /
    • pp.31-71
    • /
    • 1968
  • To clarify the breeding behavior of the hybrids between tropical and temperate area rice varieties, investigations were made on heading days and grain sterility. In this study, crosses were made in half way diallel involving 7 varieties: 2 photoperied sensitive Indicas, 2 less sensitive intermediate Indicas, 1 Ponlai Japonica and 2 high temperature sensitive Japonicas. The parents and $F_1$s were grown under 10 hours and 14 hours daylength controlled conditions at both IRRI(International Rice Research Institute, N$14^{\circ}$17') and Suwon(N$37^{\circ}$16'). F2s with their parents were grown at IRRI in the short day season, and at Suwon under natural conditions. Fa lines with their parents were grown at Suwon under natural conditions. Observations were made for heading days and sterility. The results are summarized as follow; 1. Heading days : 1. For the $F_1$s, earliness showed dominance or overdominance to lateness under the 10 hours condition, and dominance or partial dominance under the 14 hours conditions, at both IRRI and Suwon. 2. For the $F_2$s grown at IRRI during the shortday season earliness appeared to be dominant over lateness and segregation was not distinct and continuous. In the early season culture of $F_2$s at Suwon earliness showed partial dominance or was intermediate. In the proper season culture of $F_2$s lateness showed partial dominance or was intermediate. 3. In the combinations between late parental varieties which do not head at Suwon, transgressive segregants bearing effective panicles were obtained. 4. The crosses of parental varieties having long basic vegetative growth duration showed bigger variance in heading days, and significant correlation was found between of parental varieties and the mean coefficient of variance for parental arrays. 5. The means of heading days of F2 populations were significantly correlated with those of $F_1$ or mid-parents. The means of F 8 lines were also highly correlated with the means of $F_2$s, but, the means of $F_3$ lines grown at Suwon and of their parental $F_2$ individual, grown at IRRI were not correlated. 6. A faint heritability was calculated from the regression of $F_3$ lines grown at Suwon on the $F_2$ individuals grown at IRRI for most combinations, especially in the combinations involving shortday sensitive varieties. This implies low efficiency for the selection of heading days of $F_2$ individuals at IRRI to be grown in lines at Suwon. 7. No significant reciprocal effects were measured for $F_1$ and $F_2$ mean heading days. 8. Partitioning the observed photoperiod sensitivity. into two components, parental array mean md the deviation from this array mean, the parental photoperiod sensitivity contributing to the hybrids was measured in terms of general and specific combining ability for photoperiod sensitivity. 9. The photoperiod sensitivity of $F_1$s was higher than that of the parents, and it decreased as the generation progressed in most combinations of tested varieties. 10. The response of heading days to difference of temperature was weaker for $F_1$ hybrids than for the parents. The differences of temperature responses between the longday and shortday treatments were specific for the variety. 2. Sterility : 1. The $F_1$ sterility was specific for the combinations and not correlated to the parental sterility. The sterility of $F_1$s grown under the 10 hours condition was higher than of those grown under 14 hours. These results were the same at both locations, IRRI and Suwon. 2. The high sterile combinations in $F_1$ showed high sterility in $F_2$. The combinations between a high photoperiod sensitive variety and a high temperature sensitive variety showed high sterility and wider variance. 3. The mean sterility of $F_2$s was lower than of $F_1$s and the mean of $F_3$ lines was lower than of $F_2$s. Sterility decreased as the generation progressed, and the differences of $F_3$ sterility of different combinations were not significant. 4. A faint correlation between grain sterility and pollen sterility was observed in $F_2$ populations. 5. No significant reciprocal effects were measured in $F_1$ and $F_2$ sterility. 6. Following Griffing's method, specific combining ability effects were higher than general combining ability effects, especially in the combinations between highly photoperiod sensitive varieties and highly temperature sensitive varieties. 7. No distinct correlations were found between $F_2$ individual sterility grown at IRRI and $F_3$ line sterility grown at Suwon. 8. No distinct correlations were observed between heading days and sterility of $F_2$ individuals.

  • PDF

Sequential Sampling Plan for Aphis gossypii (Hemiptera: Aphididae) based on Its Intra-plant Distribution Patterns in Greenhouse Cucumber at Different Growth Stages (온실재배 오이의 생육단계별 목화진딧물의 주내 분포 특성에 기초한 축차표본조사법)

  • Chung, Bu-Keun;Song, Jeong-Heub;Lee, Heung-Su;Choi, Byeong-Ryul
    • Korean journal of applied entomology
    • /
    • v.54 no.4
    • /
    • pp.401-407
    • /
    • 2015
  • This study describes the development of a method for monitoring Aphis gossypii in greenhouse cucumber fields that was used during 2013 and 2014. The dispersion pattern of A. gossypii was determined by commonly used methods: Taylor's power law (TPL) and Iwao's patchiness regression (IPR). The sample unit was determined by linear regression analysis between mean density of sample unit versus whole plant. The optimum sample unit for different plant growth stages was two leaves (median and the lowest + 1 leaf) when the total number of leaves was less than nine, and three leaves (4th, 7th from canopy, and the lowest +1 leaf) when the total number of leaves was greater than nine. A. gossypii showed an aggregated distribution pattern, as the slopes of both TPL and IPR lines were greater than 1. TPL provided a better description of the mean-variance relationship than did IPR. The slopes and intercepts of TPL and IPR from leaf samples did not differ between the surveyed years. Fixed precision levels (D) for a sequential sampling plan were developed using Green's and Kuno's equations based on the number of aphid in a leaf sample. Green's method was more efficient than Kuno's to stop sampling. The number of samples needed to estimate the density of A. gossypii increased at higher D levels and lower mean densities. The cumulative number of aphids needed to stop sampling increased at higher D levels and with fewer plants sampled. Thus to estimate 10 aphids per leaf, 13 plants needed to be sampled, and the cumulative number of aphids to stop sampling was 131.

The Optimal Condition of Performing MTT Assay for the Determination of Radiation Sensitivity (방사선 감수성 측정법으로서 MTT 법 시행 시의 최적 조건에 대한 연구)

  • Hong, Se-Mie;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 2001
  • Purpose : The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Materials and Methods : Four human cancer cell lines - PCI-1, SNU-1066, NCI-H630 and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy. For clonogenic assay, cells in $25\;cm^2$ flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for $10\~14$ days. For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. Results : There was minimal variation in the values gained from these two methods with the standard deviation generally less than $5\%$, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the $R^2$ value of $0.975\~0.992$ between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than $30\%$). For cells with low plating efficiency (less than $30\%$), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was after 6 doubling times for the results compatible with those of clonogenic assay, at least after 4 doubling times was required for valid results. In consideration of practical limits of assay (12 days, in this study) cells with doubling time more than 3 days were inappropriate for application. Conclusion : In conclusion, it is found that MTT assay can successfully replace clonogenic assay of tested cancer cell lines after irradiation only if MTT assay was undertaken with optimal assay conditions that included plating efficiency of each cell line and doubling time at least.

  • PDF

Significance of Early Visual Responses to Anti-Vascular Endothelial Growth Factor in Age-related Macular Degeneration (신생혈관 연령관련황반변성에서 항혈관내피세포성장인자 주입술 시행 후 시력 반응의 의의)

  • Song, Hee Jun;Yang, Ji Ho;Kim, Do Gyun
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1030-1038
    • /
    • 2018
  • Purpose: To evaluate whether early visual acuity response at 4 weeks after the first intravitreal anti-vascular endothelial growth factor (VEGF) injection or 4 weeks after the third injection in neovascular age-related macular degeneration (nAMD) is associated with 12-month follow-up outcome. Methods: Thirty treatment-naive patients (30 eyes) with nAMD, treated with intravitreal anti-VEGF, were retrospectively included. Initially, all patients were injected at least three times for three consecutive months and followed up with a pro re nata regimen for at least 12 months. The relationship between 4 weeks after the first and third anti-VEGF injections in visual acuity response was explored, including the mean change from baseline in best-corrected visual acuity (BCVA). The mean change in BCVA was classified into three groups according to visual improvement: <1, 1-<3, or ${\geq}3$ logMAR line(s) in BCVA. The associations among baseline characteristics (gender, age, duration of symptoms, initial BCVA, central macular thickness, and intraocular pressure) and visual acuity responses 4 weeks after the first and third anti-VEGF injections were also assessed. Results: The proportions of eyes with <1, 1-<3, and ${\geq}3-line(s)$ improvement at 4 weeks after the first injection were 6 eyes (20%), 7 eyes (23.3%), and 17 eyes (56.6%), respectively. The proportions of eyes with <1, 1-<3, and ${\geq}3-line(s)$ improvement at 4 weeks after the third injection were 9 eyes (30%), 9 eyes (30%), and 12 eyes (40%), respectively. A BCVA response ${\geq}3-lines$ improvement at 4 weeks after the third injection showed significant associations with ${\geq}3-line(s)$ improvement and BCVA response at 12 months in multiple logistic and linear regression analyses (p = 0.04). Conclusions: In this study, BCVA response ${\geq}3-lines$ improvement at 4 weeks after the third injection showed a significant association with ${\geq}3-line(s)$ improvement and BCVA response at 12 months.

Study of plasma transforming growth factor-β1 level as a useful tumor marker in various cancers (종양 표지 인자로서 혈장 Transforming Growth Factor-β1에 대한 연구)

  • Shin, Hoon;Lim, Chang Ki;Choi, In Young;Lee, Doo Yun;Noh, Dong Yong;Ryu, Min Hee;Lee, Hyo Suk;Bang, Yung Jue;Park, Jong Sup;Jin, Seung Won
    • IMMUNE NETWORK
    • /
    • v.1 no.2
    • /
    • pp.143-150
    • /
    • 2001
  • Background : Many investigators have found transforming growth factor-${\beta}1$ (TGF-${\beta}1$) to be elevated in tumors. Changes in responsiveness to TGF-${\beta}1$ have been linked to malignant transformation, tumor progression and tumor regression. Many malignant cell lines of epithelial or hematopoietic origin are refractory to the antiproliferative effects of TGF-${\beta}1$. However, a little is known about the association of TGF-${\beta}1$ with progression of malignant tumor. Methods : In this study, we measured the plasma level of TGF-${\beta}1$ in various cancer patients and evaluated the utility of plasma TGF-${\beta}1$ as a possible tumor marker. Plasma TGF-${\beta}1$ levels were measured using enzyme-linked immunosorbent assay in cancer patients and normal controls. Carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP) as tumor marker were compared with TGF-${\beta}1$ in the aspects of sensitivity and specificity. Results : The mean of plasma TGF-${\beta}1$ levels was $1.219{\pm}0.834ng/ml$ in normal controls, $5.491{\pm}3.598ng/ml$ in breast cancer, $12.670{\pm}10.386ng/ml$ in lung cancer, $5.747{\pm}3.228ng/ml$ in hepatocellular carcinoma and $10.854{\pm}7.996ng/ml$ in cervical cancer. In comparison with CEA and AFP, TGF-${\beta}1$ is more sensitive. Conclusion : We conclude that the high levels of TGF-${\beta}1$ are common in the plasma of cancer patients. These results suggest that the plasma TGF-${\beta}1$ level can be a potent tumor marker in various cancer patients.

  • PDF

Role of Endothelium-derived Relaxing Factor in Cerebral Autoregulation in vivo (뇌혈류 자가조절에 대한 Endothelium-derived Relaxing Factor의 역할)

  • Hong Ki-Whan;Yu Sung-Suk;Rhim Byung-Yong
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.1 s.57
    • /
    • pp.27-37
    • /
    • 1995
  • In anesthetized rats, we examined the possibility that endothelium-derived relaxing factor (EDRF) or nitric oxide (NO) released in response to cholinergic mechanism may contribute to the reflex autoregulation of cerebral blood flow. Suffusion with mock cerebrospinal fluid (CSF), containing acetylcholine (ACh, $10^{-9}{\sim}10^{-6}M$) evoked concentration-dependent vasodilatation of the resting pial artery (mean, $19.3{\pm}1.7{\mu}m$, n=36), which was significantly inhibited not only by $N{\omega}$-nitro-L-arginine (L-NNA, $10^{-5}M$) but also by methylene blue ($10^{-6}M$) and oxyhemoglobin ($10^{-6}M$). The muscarinic receptors in the endothelium of pial artery implicated in the release of EDRF were considered to be $M_1\;and\;M_3$ subtypes. When suffused with mock CSF containing L-arginine it caused a transient vasodilatation, which was strongly inhibited by LY 83583 ($10^{-5}M$), but not by L-NNA ($10^{-5}M$). Additionally, both ACh- and L-arginine-induced vasodilation were significantly inhibited by glibenclamide, a specific ATP-sensitive $K^+$ channel blocker. On the other hand, changes in pial arterial diameter were plotted as a function of changes in systemic arterial blood pressure. The slopes of regression lines for vasodilation and vasoconstriction were not affected by pretreatment with $10^{-5}M$ L-NNA, but significantly reduced by $3{\times}10^{-6}M$ glibenclamide. Thus it is suggested that the reflex vasodilation of rat pial arteries in response to a transient hypotension is not mediated by EDRF (NO).

  • PDF

Analysis of Varietal Variation in Alkali Digestion of Milled Rice at Several Levels of Alkali Concentration (쌀의 KOH 농도별 붕괴양상에 따른 품종변이 해석)

  • 최해춘;손영희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.1
    • /
    • pp.31-37
    • /
    • 1993
  • To analyze and classify the varietal variation of alkali digestibility in detail, which is closely connected with the gelatinization temperature and physical characteristics of cooked rice, the patterns of alkali decomposition changed along the alkali concentration were investigated for thirty three Korean leading rice cultivars and new breeding lines(japonica : 25, Tongil-type:8) including five glutinous rice. Principal component analysis was used to condense the information and to classify rice materials according to decomposed reaction pattern at several levels of potassium hydroxide(KOH) concentration. Thirty three rice varieties were classified largely into four groups by the distribution on the plane of upper two principal component scores which contained above 92% of total informations. Group I was consisted of one variety, Dobongbyeo, which owned almost same strong resistance to alkali digestion at the range of 0.8% to 1.6% KOH solutions. Group II included three japonica and Tongil-type glutinous rice varieties, which revealed medium alkali digestion value(ADV) at 1.4% KOH solution and intermediate change in ADV from 0.8% to 1.6% KOH solutions. Most of Tongil-type and early-maturity japonica rice, which exhibited medium-high ADV at 1.4% of KOH concentration and large ADV difference between low and high alkali solutions, were contained in Group III. Group N included most of medium or medium-late-maturity japonica, which showed high ADV at 1.4% KOH and medium or intermediate-high ADV change between low and high alkali solutions. The 1st principal component indicated the average index of ADV through 0.8-1.6% KOH solutions and the 2nd principal component pointed out the factor related with ADV difference between low and high alkali solutions or regression coefficients of ADV change along with the KOH concentrations.

  • PDF