• Title/Summary/Keyword: refrigeration storage

Search Result 356, Processing Time 0.034 seconds

Investigation of Domestic Refrigeration and Freezing Warehouses (국내 냉장냉동 창고 현황 조사)

  • Sun, Il-suck
    • Journal of Distribution Science
    • /
    • v.6 no.2
    • /
    • pp.5-19
    • /
    • 2008
  • This study aims to provide the present general state of basic data about refrigeration and freezing warehouses scold storages because basic data about refrigeration and freezing warehouses are insufficient and imperfect at the moment. Research contents include the present general state of cold storages such as sales amount, capital(money invested), storage possession state by type, keeping area, cold storage facility capacity, and facility state such as existence of rack, building structure and floor height, and possessed facility state. According to research results, it was found that 86.7% of refrigeration and freezing warehouses are located in the capital region and Busan region in terms of regional distribution, and the average keeping area was found to be bigger in these two regions than that of other regions. In addition, the research shows that more than 80% of companies possess bonded warehouses and there was no big difference in the size and capacity of refrigeration and freezing warehouses. Regarding building structure, most of them were found to be reinforced concrete. However, only 25% of companies installed racks, but there was no statistical significance between existence of rack and the amount of capital and sales. Possessed facilities were found in the order of freight elevator, information system and dock. When it comes to cargo gear, companies were found to possess 9.1 units of forklift and 2.2 units of reach stacker in average. This research is expected to lay a basis for investigating, predicting and developing the local cold storage industry, and more detailed studies will be needed in the future.

  • PDF

Economical Efficiency Evaluation of the Cold Storage Warehouse with Various Envelope Structures (냉동냉장창고 외피구조 유형별 경제성 평가)

  • 송승영;석호태;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1156-1164
    • /
    • 2001
  • This study aims to suggest envelope structure which can improve the insulation performance of cold storage warehouse with cost effectiveness. Envelope structures are classified and economical efficiency of each type is evaluated to the model warehouse. As results, type 3 (PC wall) and 4(sandwich panel wall) have benefits to the middle/large (lifetime of 25 years) and small (lifetime of 12∼13 years) warehouse, respectively.

  • PDF

Optimal Control Algorithms for the Full Storage Ice Cooling System (전축열방식 빙축열 시스템의 최적제어 알고리즘)

  • 한도영;이준호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.350-357
    • /
    • 2002
  • Optimal control algorithms for the full storage ice cooling system were developed by using a dynamic simulation program. Control algorithms for the storage charging mode were developed for the chiller outlet temperature setpoint control and the chiller capacity control. Control algorithms for the storage discharging mode were developed for the proper mode selection, the storage-only mode control, and the storage-priority chiller-shared mode control. Two different cases of the expected outdoor air temperature profile and the expected cooling load profile were used to analyze the effectiveness of these algorithms. Simulation results show the energy savings and the satisfactory controls of the ice storage system. Therefore, control algorithms developed for this study may effectively be used for the improved control of the ice storage cooling system.

A Study on latent heat storage system with Solar heat(Part 1. Development of PCM modeling) (태양열을 이용하는 잠열축열 시스템에 관한 연구(제1보 PCM 계산 모델의 개발))

  • Ku, H.G.;Kim, J.R.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.47-54
    • /
    • 2001
  • This study has been conducted to verify the possibility of adaptation of a latent storage type air-conditioning system, shifting the peak load of electronic power to a building. In this paper, an energy equation to evaluate performance of PEM(phase change material) has been suggested and solved, after discretization. As a result, it is confirmed that the results from the energy equation are correspond with those from present studies to analysis of one-dimensional solidification and to analysis of two-dimensional solidification.

  • PDF

An Analysis of the Optimal Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage : An Analysis by the Gradient Method Algorithm (슬래브축열의 최적축열시간 산정 : 구배법 알고리즘에 의한 해석)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.702-709
    • /
    • 2008
  • In this paper, the optimal thermal storage time of an air-conditioning system with slab thermal storage in office building was analyzed on the basis of the gradient method algorithm. The sum of room temperature deviation and heat extraction rate was set to the criterion function. It was calculated that four hours is the optimal thermal storage time under the standard evaluation criterion. Furthermore, some case studies were executed by controlling ratio of weight functions of room temperature deviation and heat extraction rate in criterion function. It is possible to design many kinds of optimal operation of an air-conditioning system with slab thermal storage by controlling ratio of the weight functions in criterion function.

Performance Characteristics of Two-stage Compression Seawater Ice Machine Applied Drum type Evaporator (드럼형 증발기를 적용한 2단 압축 해수 제빙시스템의 성능 특성)

  • Son, Chang-Hyo;Yoon, Jeong-In;Jeon, Min-Ju;Lee, Hyun-Kyung;Heo, Seong-Kwan
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • In the fishing boat, freshwater ice is loaded on the fishroom in advance and it is used for storage of fishes. However, it causes degradation of catches' freshness. Therefore, seawater ice machine on board is necessary for the fishing industry. In this study, seawater ice machine with drum type evaporator was manufactured, and the system was tested under various operating conditions having an influence on the COP and amount of ice produced. The main results are as follow : The COP of the system gets larger when the evaporation temperature and rotation speed of the drum in the evaporator increases. The most effective refrigerant is R22 and the value of the COP was 1.43 times higher than that of R404A. The amount of produced ice increases with respect to increment of the evaporation temperature, while that decreases with respect to increment of the evaporator drum rotation speed.

Magnetic refrigerator for hydrogen liquefaction

  • Numazawa, T.;Kamiya, K.;Utaki, T.;Matsumoto, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

Effect of Cooking, Reheating Methods and Storage Conditions on the Quality Characteristics of ′Nuhbiani′ (조리, 재가열 방법 및 저장 조건이 너비아니 품질 특성에 미치는 영향)

  • 김정원;김희섭
    • Korean journal of food and cookery science
    • /
    • v.11 no.5
    • /
    • pp.494-502
    • /
    • 1995
  • The study was conducted to evaluate the characteristics of Nuhbiani qualities with the different cooking, reheating methods and storage conditions. Cooking and reheating methods were used with pan, microwave and their combinations. Precooked samples were stored for 0, 1, 4, 7, 15 days in the refrigerator and for 15, 30 days in the freezer. TBA value, shear value by rheometer and sensory attributes in rancidity, hardness, juiciness and overall acceptability were measured. There was no significant difference between cooking, reheating methods in TBA values. Lower values in TBA were noted in the Nuhbiani of frozen storage as compared with that of refrigerated storage. There is a tendency that TBA values were increased as the storage time extended during the refrigeration. Shear values were more increased by microwave cooking and microwave reheating than other methods showing harder texture. Results from sensory evaluation of rancidity, hardness, juiciness and overall acceptability show that there were no significant differences between storage methods, among storage periods and cooking, reheating methods.

  • PDF

The Study of Economical Efficiency for the Ice Storage System of more Energy Consumption Building (에너지 다소비형 건물 축냉 시스템의 경제성에 관한 연구)

  • Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.733-738
    • /
    • 2012
  • It is important issue to reduce the electric energy to save the operating cost of HVAC system. Even if electrical energy is the clean energy, it is difficult and takes high cost for storage of electricity. These cause the high peak load of electric energy for HVAC in summer season. In korea, government impose the electric charge with several grade for the purpose of cut-off the peak load of electricity. Government has a policy to support to design and install the heat/ice storage system using midnight electricity. In this study, analysis of cooling load and operating characteristics for ice storage system are performed. And, also economical efficiency is compared between ordinary charge system of electricity and midnight rate charge of electricity. The systematic and economical supports are needed for expansion of usage of energy saving equipments.

An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage (슬래브축열 공조시스템의 축열성능에 관한 실험적 연구)

  • Jung Jae-Hoon;Shin Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.