• 제목/요약/키워드: refrigeration storage

검색결과 357건 처리시간 0.026초

나선유로에 의한 태양열 축열조 성층화 촉진(제1보 실증실험) (Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 1:Verification Experiment))

  • 권재욱;홍희기
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.336-342
    • /
    • 2012
  • Large-scale active solar heat systems are generally using heat exchanger between collector and storage tank loops to prevent damage by freezing. It is difficult to maintain stratification in a storage tank in the system owing to greater flow rate enhancing heat transfer. In the previous study, we introduced a spiral-jacketed storage tank and obtained good results to keep system performance of general level without better stratification. We added a scroll-shaped heat exchanger coil on the upper part in the spiral-jacketed storage tank. As a result of the experiment, it was verified that degree of stratification of the new type storage tank is higher than that of the previous one with a possibility of better collector efficiency and solar fraction.

침지용액과 예열 처리가 감자 슬라이스의 냉장 중 갈변정도에 미치는 영향 (Effects of Dipping and Preheating Treatments on Susceptibility to Browning of Potato Slices During Cold Storage)

  • 정현미;이귀주
    • 한국식품조리과학회지
    • /
    • 제12권4호
    • /
    • pp.535-540
    • /
    • 1996
  • 감자 슬라이스를 CaCl$_2$ 용액과 chitosan 용액에 침지 하거나 혹은 이들 용액의 존재하에서 예열처리 한 후 냉장저장하여 침지 및 예열처리가 감자 슬라이스의 갈변정도, 페놀 함량, PPO 활성의 변화에 대한 영향을 조사한 결과는 다음과 같다. 1. 감자 슬라이스의 L값은 감소하는 경향을 나타내었으나, CaPS는 2주까지 L값이 증가하였고, ChPS는 4주간 L값이 증가하였다(p < 0.05). 또한 예열처리에 의 한 병용 효과에 의해 L값이 가장 증가하였다(p < 0.05). 2. CaPS를 제외한 각 처리군은 total phenol 함량이 감소하였으며(p < 0.05) 예열처 리 한 감자 슬라이스의 total phenol 함량이 더욱 감소하였다(p < 0.05). chloro-genic aicd 함량은 HCaPS를 제외하고 total phenol 함 량의 변화와 같은 경향을 나타내었다. 3. PPO 활성은 침지 및 예열처리를 통하여 감소하였는데 예열처리에 의한 감자 슬라이스의 PPO 활성 이 더욱 감소하였다 이로부터 CaCl$_2$,및 chitosan 용액에 침지 및 예열처리가 갈변억제에 효과적인 것으로 생각되어지며 L값 은 증가하고 페놀함량과 PPO 활성이 감소하였다. 이 러한 효과는 열처리군에서 더 크게 나타났다.

  • PDF

빙축열조를 이용한 냉매과냉각 시스템 기초연구 (Basic Study on Sub-cooling System using Ice storage tank)

  • 이은지;이동원;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.990-995
    • /
    • 2009
  • Experimental basic study was performed to understand the characteristics of sub-cooled refrigerant using a cold heat storage system. This system was made up general vapor-compression refrigeration cycle added sub-cooler and ice storage tank. The purpose of this study are to application use of cold-heat storage systems multiplicity of fields and to understand of sub-cooling system. At the condition using ice storage system, the ice making process was operated during night time by electric power. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. Comparing the result at general operation with the operation using sub-cooling system. This study showed the effects of the sub-cooled degree. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, and the compressor consume power was a little decreased. Thus the COP was also increased owing to the sub-cooling of refrigerant.

  • PDF

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

냉열잠열축열조의 성능해석 (Performance of the Cold Latent Storage System)

  • 윤호식;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.456-465
    • /
    • 1988
  • The performance of the cold latent heat storage is investigated by experiment and by a simplified analytic approach. The heat storage tank has eight horizontal circular tubes and one path of refrigerant evaporating tube. The phase change material in the heat storage tank is water which is frozen by evaporating refrigerant of refrigeration system and melts by the warm air in the heat storage tank. In the experiment, the performance has been studied by the various conditions including the initial water temperature on solidification and flow rate and temperature of air. The rate of recovered heat has been simulated by a simplified model and the results shows a good agreement. In solidification process, initial water temperature causes time delay corresponding to the sensible heat and it is found that the shape of evaporator is important. In melting process, the recovered heat rate from the heat storage tank is proportional to $Re^{0.8}(T_{bi}-T_f)$ of air where $T_{bi}$ and $T_f$ indicate temperatures of inlet air and phase change, respectively. And the deminishing rate of the recovered heat is higher for the higher heat rate.

  • PDF

온도 성층축열조 가시화 및 실증분석에 관한 고찰 (Effect on Stratification due to Diffuser Shape in a Thermal Storage Tank)

  • 이영수;이상남;김종률
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.990-997
    • /
    • 2005
  • The stratified effect was investigated with three different types of diffuser shape in a thermal storage tank with variation of diffuser diameter, velocity, Froude number etc. Its effect was estimated by the degree of stratification. No matter of diffuser diameter and shape, the degree of stratification was the best as the Froude number gets closer to 1. In the case of a curved diffuser, when its diameter is a quarter of tank diameter and ejection velocity in a diffuser is approximately 0.2 m/s, the Froude number was almost 1. In the case of a flatted diffuser, when ejection velocity was 0.05 m/s, the Froude number was 1.5. Both cases which Froude number were nearer 1, showed the good degree of stratification.

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

UHT처리된 우유의 영양 및 미각적 분석 (Nutritional and Organoleptical Aspects of UHT Treated Milk)

  • 홍윤호
    • 한국식품과학회지
    • /
    • 제14권3호
    • /
    • pp.276-282
    • /
    • 1982
  • 초고온 살균(UHT) 처리와 이에 따른 저장이 우유의 영양가에 미치는 효과에 대하여 토론되었다. 초고온 처리된 우유는 재래의 멸균우유와 비교해 상당히 적은 열 부담을 받는다. 일반적으로 초고온 살균처리 공정중에는 단백질, 지방, 유당, 지용성 비타민과 무기물들의 영양가들은 거의 영향을 받지 않는다. 작은 정도의 수용성 비타민들과 약간의 단백질의 영양가치가 저장중에 손실된다. 우유의 향미와 영양가를 최대한으로 유지하기 위해서는 초고온 살균우유는 냉장온도에 저장되어야 한다고 권장되고 있다.

  • PDF

Thermal Performance of the Microencapsulated PCM

  • Lee, Hyo-Jin;Lee, Jae-Goo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.31-39
    • /
    • 2002
  • Microencapsulated pcm (MPCM) particles are mixed with distilled water and utilized to evaluate its characteristics and performance as a thermal storage medium transporting heat. For the present study, tetradecane ($C_14$$H_30$, $T_m$=5.5$^{\circ}C$) is capsulated in the core, coated with the melamine for their surface. The size of particles is well-controlled under 10$\mu$m in the process of in-situ polymerization with melamine-formaldehyde resin. For the experiment, the concentractions of slurries are prepared for 20 wt%, 30 wt%, and 40 wt%. The results are compared with those of water and 100% tetradecane oil. The pure water and tetradecane start solidifying within 20 minutes after introducing cooling water into the thermal storage tank whose flow rates are varied by 125 cc/min, 250 cc/min, and 500 cc/min. However, MPCM slurries are required relatively longer period of time for their phase change than pure phase change materials. That is, the entrained MPCM particles restrict their heat transfer in terms of natural convection and conduction to them.