• 제목/요약/키워드: refractive-index matching

검색결과 36건 처리시간 0.024초

광변조기용 CPW 전극제작 및 특성 (Fabrication and Properties of CPW Electrode for Optical Modulator)

  • 임영삼;김영준;박계춘
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.962-965
    • /
    • 1999
  • We designed and fabricated a travelingwave CPW(coplanar waveguide) electrode for LiNbO$_3$ optical modulator. To Investigate the variation of microwave refractive index of these electrodes, we prepared the CPW electrode samples as a function of electrode thickness and measured the TDR and S-parameter. From this results, we could know the electrode conditions of index matching to 2.20 for 1550nm optical wave index for applying LiNbO$_3$ optical modulator and described. Also, we discussed the some properties of CPW electrode for applying LiNbO$_3$ optical modulator.

  • PDF

주기적으로 분극반전된 $LiNbO_3$ 결정에서 광매개증폭 (Optical Parametric Oscillation in Periodically Poled Lithium Niobate Crystal)

  • Kim Hong-Gi;Cha Myeong-Sik;Lee Beom-Gu
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.222-223
    • /
    • 2001
  • Optical parametric oscillator(OPO) has been used to generate coherent and tunable laser source with birefringent phase-matching technique in various nonlinear materials. In birefringent phase-matching, the output wavelength is controlled with angle or temperature tuning of the refractive index. However these tuning methods have several limitations such as restriction of tuning wavelength due to reasonable angular and temperature tuning ranges, Poynting vector walk-off which limits the interaction length, and thermal stabilization time. (omitted)

  • PDF

격자 구조형 스트립 방향성 결합기에 기초한 광 바이오-센서의 고 민감도 분석 (High Sensitivity Analysis of Optical Bio-Sensor based on Grating-Assisted Strip Directional Coupler)

  • 호광춘
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.157-162
    • /
    • 2023
  • 격자 구조형 스트립 방향성 결합기를 기반으로 한 고 민감도 굴절률 bio-sensor를 제안하였다. 그 센서는 도파관 중 하나의 상단 층에 격자 구조가 구성된, 두 개의 비대칭 스트립 도파관을 사용하여 설계하였다. 위상정합 조건을 만족하는 공진 파장에서 한 도파관으로부터 다른 도파관으로 최대 광 결합이 발생하며, 도파관 표면 영역에 놓인 분석물질의 굴절률 변화에 따른 위상정합 조건의 변화가 민감도를 측정하는 척도로 사용될 수 있음을 보여주었다. 제안된 센서는 높은 굴절률 민감도를 가진 on-chip 장치로 설계될 수 있으며, 낮은 전파 손실을 제공하여 민감도가 향상되도록 센서를 구성되었다. 더욱이, 도파관 파라미터에 따른 민감도 변화가 센서의 설계 최적화를 위하여 분석되었다.

광중합 전후 복합레진의 광학적 특성 (Optical characteristics of resin composite before and after polymerization)

  • 엄아향;김덕수;이수희;변창원;박노훈;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.219-230
    • /
    • 2011
  • 연구목적: 복합레진의 광중합 전후에 일어나는 색과 투명도 변화를 측정하고, CQ의 함량을 정량하였으며, 광중합 전후 복합 레진의 굴절률을 측정해 이들의 상관 관계를 알아보고자 하였다. 연구 재료 및 방법: Esthet-X, Filtek supreme, Gradia Direct, Clearfil Majesty, Beautifil II에 대하여 Colorimeter NF999를 이용하여 광중합 전후의 색과 투명도를 각각 측정하고, GC-MS를 이용해 각 복합레진의 CQ 함량을 측정하였으며, spectroscopic ellipsometer를 이용해 광중합 전후의 굴절률을 측정하였다. 결과: 투명도는 광중합 후에 증가하였고, body shade에서 opaque shade보다 투명도 차이가 크게 나타났다. 모든 레진에서 body shade의 CQ 함량이 opaque shade의 CQ 함량보다 높았다. 굴절률은 광중합 후에 모든 레진에서 증가하였으며, body shade와 opaque shade간에 굴절률의 변화는 유의한 차이가 있었다. 결론: 광중합 후에는 복합레진의 색과 투명도가 상당한 차이를 나타낸다. 따라서 임상에서 direct shade matching을 시행할 때는 중합된 레진을 사용하여야 한다.

조직투명화 기술을 통한 3차원적 접근 (Three-Dimensional Approaches in Histopathological Tissue Clearing System)

  • 이태복;이재왕;전진현
    • 대한임상검사과학회지
    • /
    • 제52권1호
    • /
    • pp.1-17
    • /
    • 2020
  • 조직병리학에서 현미경을 이용한 삼차원적 접근법은, 이차원 단면의 조직 슬라이드에서 박절 과정 중 부차적으로 발생하는 공간정보의 손실로 인하여 확인하기 어려웠던, 조직 내부 분자들의 공간적 배열, 상호결합, 구조적인 형태와 이들의 통합적인 공간적 정보체로서, 조직 내에 복잡하게 얽혀진 다양한 정보를 풀어내는데 있어서 복합적인 데이터를 제시하여 준다. 이광자 현미경(two-photon microscope)과 자동화된 보정환(correction collar)이 탑재된 고성능 대물렌즈의 개발과 같은 광학장비 영역의 발전은 조직투명화 과정을 거치지 않은 두꺼운 시료의 이미징에 있어서 광학적인 이론과 실체 사이에 존재하는 격차를 줄이는데 기여하였다고 할 수 있다. 하지만, 대물렌즈의 길어진 작동범위(working distance)와 최적화된 고강도 레이저의 사용으로 얻게 되는 이점들은 세포 내 각 구성요소의 굴절률(refractive index) 차이로 인하여 증가되는 빛의 분산(light scattering) 현상으로 인해 자연스럽게 감소하게 된다. 조직투명화 기술이 처음 등장하였던 초창기 시도되던 간단한 굴절률 일치화(RI matching) 기법에서부터 현대의 최첨단 통합 조직 투명화 기술에 이르기 까지를 관찰하여 볼 때, 형태학적인 변화없이 조직의 투명도를 높이는 것과, 내재적으로 또는 고정과정 중에 유래되어 혼합된 자가형광 노이즈를 효과적으로 제거하는것이 선명한 이미지를 얻기 위한 주요한 고려대상이라고 할 수 있다. CLARITY는 장비에 기반한 조직투명화 기법으로서 임상 조직병리 실험실에서 처리되는 동결절편과 포르말린에 고정된 검체 모두의 투명화를 위한 실험실 작업흐름(workflow) 통합 및 일상적인 실험절차와 호환이 가능할 것으로 보여진다.

점정합법에 의한 반원형 광도파로 벡터 해석 (The Vector Analysis by Point Matching Method for Semicircular Optical Waveguide)

  • 라경태;김상덕;김종빈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.323-326
    • /
    • 1999
  • This paper describes a point matching method that is based on an expansion of the electromagnetic field in terms of a series of Bessel and modified Bessel functions multiplied by trigonometric functions. In this method, the electric and magnetic fields inside the waveguide core are matched to those outside the core at matching points on the boundary to yield matrix equations. As an example applying this method, the paper presents the results of the computation in the form of curves of the propagation constants in a semicircular optical waveguide, be formed by annealing for reduced insertion(radiation) loss when connected to optical fiber. The propagation curves are presented in a form of refractive index independent. Also, it presents relative energy distributions between inside the core and outside the core of various modes and presents field distributions.

  • PDF

Flow Visualizations and Laser Doppler Velocity Measurements in a Fontan Connection

  • Kim, Young-H.;Yoganathan, Ajit P.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.111-114
    • /
    • 1994
  • Three component velocity measurements with a refractive index-matching technique was used to investigate the flow characteristics in the atrio-pulmomnary (AP) Fontan connection under the steady flow condition. A strong swirl was observed in the extra-cardiac conduit and the main pulmonary artery (MPA). Maximum velocity magnitude in the MPA was about 0.8 m/s near the posterior wall at 6 liter/min. Swirling motion of the flow as well as geometric abnormalities of the connection are important factors in energy loss across Fontan connections.

  • PDF

Control of Free Spectral Range of tong Period Fiber Grating by Cladding Mode Waveguide Dispersion

  • Jeong, H.;Oh, K.
    • Journal of the Optical Society of Korea
    • /
    • 제7권2호
    • /
    • pp.89-96
    • /
    • 2003
  • A new method to control the free spectral range of a long period fiber grating is proposed and theoretically analyzed. As the refractive index decreases radially outward in the silica cladding due to graded doping of fluorine, waveguide dispersion in the cladding modes was modified to result in the effective indices change and subsequently the phase matching conditions for coupling with the core mode in a long period fiber grating. Enlargement of the free spectral range in a long period fiber grating was theoretically confirmed.

광변조기용 CPW 전극제작 및 특성 (Fabrication and Properties of CPW Electrode for Optical Modulator)

  • 임영삼;김성구;박계춘;이진;정해덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.278-281
    • /
    • 1999
  • We designed and fabricated a travelingwave CPW(coplanar waveguide) electrode for LiNbO$_3$ optical modulator. To Investigate the variation of microwave refractive index of these electrodes, we prepared the CPW electrode samples as a function of electrode thickness and measured the TDR and S-parameter. From this results, we could know the electrode conditions of index matching to 2.20 for 1150 nm optical wave index for applying LiNbO$_3$ optical modulator. Also we discussed the some properties of CPW electrode for applying LiNbO$_3$ optical modulator.

  • PDF

반사율 측정에 의한 적외선 광학재료의 중적외선 굴절률 추정 (Estimation of Refractive Index in MIR range from the Reflectance Measurements for IR Optics Materials)

  • 진두한;정경석
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.411-416
    • /
    • 2020
  • 본 연구는 적외선 광학재료의 중적외선 영역의 굴절률을 파악하기 위해 반사율을 측정하고 굴절률과 반사율의 관계로부터 굴절률을 추정하는 방법을 제안한다. 전반사 거울 4개를 일정한 간격으로 배열하고 적외선 광원으로부터 연속 파장의 평행광이 45°로 입사되도록 광 경로를 구성한다. 광 경로를 따라 4개의 전반사 거울에 반사되어 온 광강도 IB를 측정한 후, 광 경로의 마지막에 놓이는 거울을 시편으로 교체하고 광강도 Is를 측정한다. IB와 Is, 전반사 거울의 비를 이용하여 재료의 반사율을 계산한다. 계산된 반사율과 Fresnel의 굴절률과 반사율 관계식에 넣고 시행착오법으로 굴절률을 추정한다. 이 방법을 적용하여 사파이어(Al2O3), 게르마늄(Ge), 불화마그네슘(MgF2), 황화아연(ZnS)재료를 대상으로 실험하고 굴절률을 추정하여 참고문헌자료들과의 비교를 통하여 모든 재료에 대해 파장범위 3 - 5㎛에서 최대 차이 2% 이하로 잘 일치하는 결과를 얻을 수 있었으며, 이를 통해 본 굴절률 측정방법의 타당성을 확인할 수 있다. 본 연구에서 제시된 방법은 연속 파장의 적외선 광원을 사용하기 때문에 한 번의 측정으로 여러 파장에 대한 굴절률을 추정 할 수 있는 장점이 있다.