• 제목/요약/키워드: reference standard

검색결과 2,162건 처리시간 0.023초

Time-Dependent Effects of Prognostic Factors in Advanced Gastric Cancer Patients

  • Kwon, Jin-Ok;Jin, Sung-Ho;Min, Jae-Seok;Kim, Min-Suk;Lee, Hae-Won;Park, Sunhoo;Yu, Hang-Jong;Bang, Ho-Yoon;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • 제15권4호
    • /
    • pp.238-245
    • /
    • 2015
  • Purpose: This study aimed to identify time-dependent prognostic factors and demonstrate the time-dependent effects of important prognostic factors in patients with advanced gastric cancer (AGC). Materials and Methods: We retrospectively evaluated 3,653 patients with AGC who underwent curative standard gastrectomy between 1991 and 2005 at the Korea Cancer Center Hospital. Multivariate survival analysis with Cox proportional hazards regression was used in the analysis. A non-proportionality test based on the Schoenfeld residuals (also known as partial residuals) was performed, and scaled Schoenfeld residuals were plotted over time for each covariate. Results: The multivariate analysis revealed that sex, depth of invasion, metastatic lymph node (LN) ratio, tumor size, and chemotherapy were time-dependent covariates violating the proportional hazards assumption. The prognostic effects (i.e., log of hazard ratio [LHR]) of the time-dependent covariates changed over time during follow-up, and the effects generally diminished with low slope (e.g., depth of invasion and tumor size), with gentle slope (e.g., metastatic LN ratio), or with steep slope (e.g., chemotherapy). Meanwhile, the LHR functions of some covariates (e.g., sex) crossed the zero reference line from positive (i.e., bad prognosis) to negative (i.e., good prognosis). Conclusions: The time-dependent effects of the prognostic factors of AGC are clearly demonstrated in this study. We can suggest that time-dependent effects are not an uncommon phenomenon among prognostic factors of AGC.

정상 성인의 정중지단신경에 대한 전기생리학적 연구 (An Electrophysiologic Study on the Median Digital Nerves in Healthy Adults)

  • 김종순;이현옥;안소윤;구봉오;남건우;류재관;류재문
    • The Journal of Korean Physical Therapy
    • /
    • 제17권3호
    • /
    • pp.329-338
    • /
    • 2005
  • The determination of peripheral nerve conduction velocity is an important part to electrodiagnosis. Its value as neurophysiologic investigative procedure has been known for many years but normal value of digital nerve was not reported in Korea. To evaluate of digital nerve conduction velocity of median nerve for obtain clinically useful reference value and compare difference in each fingers. 71 normal volunteers(age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II was use for detected conduction velocity and amplitude of digital nerves in median nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation, ANOVA was used to compare each fingers and independent t-test was used to compare between Rt and Lt side also compare between different in genders. Conduction velocity of the right thumb was 49.77m/sec, index finger was 56.80m/sec, middle finger was 56.15m/sec and ring finger was 53.38m/sec. The left thumb was 50.48m/sec, index finger was 56.76m/sec, middle finger was 55.99m/sec and ring finger was 53.23m/sec. Amplitude of the right thumb was $64.30{\mu}V$, index finger was $73.95{\mu}V$, middle finger was $77.97{\mu}V$ and ring finger was $43.92{\mu}V$. The left thumb was $74.21{\mu}V$, index finger was $85.72{\mu}V$, middle finger was $88.06{\mu}V$ and ring finger was $47.28{\mu}V$. There were significantly difference between thumb, index, middle and ring fingers(p<.01) but there were no statistically difference between conduction velocity and amplitude of index and middle fingers(p>.01). The conduction velocity of index finger are faster than other fingers and amplitude of middle finger are greater than other fingers. The present results revealed that electodiagnosis can easily perform in index and middle finger for digital nerve of median nerve study.

  • PDF

한국어 음성인식 플랫폼 (ECHOS) 개발 (Development of a Korean Speech Recognition Platform (ECHOS))

  • 권오욱;권석봉;장규철;윤성락;김용래;장광동;김회린;유창동;김봉완;이용주
    • 한국음향학회지
    • /
    • 제24권8호
    • /
    • pp.498-504
    • /
    • 2005
  • 교육 및 연구 목적을 위하여 개발된 한국어 음성인식 플랫폼인 ECHOS를 소개한다. 음성인식을 위한 기본 모듈을 제공하는 BCHOS는 이해하기 쉽고 간단한 객체지향 구조를 가지며, 표준 템플릿 라이브러리 (STL)를 이용한 C++ 언어로 구현되었다. 입력은 8또는 16 kHz로 샘플링된 디지털 음성 데이터이며. 출력은 1-beat 인식결과, N-best 인식결과 및 word graph이다. ECHOS는 MFCC와 PLP 특징추출, HMM에 기반한 음향모델, n-gram 언어모델, 유한상태망 (FSN)과 렉시컬트리를 지원하는 탐색알고리듬으로 구성되며, 고립단어인식으로부터 대어휘 연속음성인식에 이르는 다양한 태스크를 처리할 수 있다. 플랫폼의 동작을 검증하기 위하여 ECHOS와 hidden Markov model toolkit (HTK)의 성능을 비교한다. ECHOS는 FSN 명령어 인식 태스크에서 HTK와 거의 비슷한 인식률을 나타내고 인식시간은 객체지향 구현 때문에 약 2배 정도 증가한다. 8000단어 연속음성인식에서는 HTK와 달리 렉시컬트리 탐색 알고리듬을 사용함으로써 단어오류율은 $40\%$ 증가하나 인식시간은 0.5배로 감소한다.

지대치 형태에 따른 지르코니아 코어의 변연 적합도 (Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth)

  • 김기백;김석환;김재홍
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.54-59
    • /
    • 2015
  • 본 연구는 시중에 널리 사용되는 치과용 지르코니아 코어를 이용하여 서로 다른 형태의 지대치를 대상으로 작업모형을 제작한 후, 치과용 스캐너를 통해 3차원 디지털 모형을 전환한 데이터를 토대로 지르코니아 코어를 제작하였으며, 각 실험군별 변연 적합도를 측정하여 비교분석하고자 하였다. 이와 같은 결과로 형태가 다른 지대치가 CAD/CAM system으로 치과 보철물 제작 시 적합도의 영향여부를 비교하였다. 제한된 조건 하에서 수행된 본 연구에서 다름과 같은 결과를 보였다. 지대치의 형태가 다른 작업모형으로 제작된 지르코니아 코어의 변연 적합도는 큰 차이가 없었다(p>0.05). 작업모형의 부위를 4등분으로 나누어 측정한 변연 적합도 또한 통계적으로 유의한 차이를 보이지 않았다. 결론적으로 3종류의 다른 지대치 모두 유사한 지르코니아 코어의 변연 적합도를 보였으며, 측정된 결과는 선행연구에 비추어 볼 때 임상적으로 허용 가능한 수치($100{\sim}120{\mu}m$)를 초과하는 실험군은 없었다. 이와 같은 결과를 토대로 다른 형태의 지대치를 사용하여 제작되었더라도 지르코니아 코어의 변연 적합도에 큰 영향을 주지 않을 것으로 생각된다.

Immunoblotting 에 의한 Aspergillus fumigatus 균주(菌株)의 항원분석(抗原分析)과 이 균(菌)에 감염(感染)된 환자의 항체반응(抗體反應)에 관한 연구 (Analysis of Culture Filtrate Antigens of Aspergillus fumigatus Strains and of Antibody Responce in Patients with Aspergillosis by Immunoblotting)

  • 김상재;김신옥;홍영표
    • 한국균학회지
    • /
    • 제17권2호
    • /
    • pp.66-75
    • /
    • 1989
  • 임상가검물(臨床可檢物)로부터 분리(分離)된 Aspergillus fumigatus 균주(菌株)의 항원조성(抗原造成)과 이균에 감염(感染)된 환자의 항체반응(抗體反應)의 다양성을 Immunoblotting으로 관찰하였다. SDS-PAGE와 immunoblots상에 나타난 결과를 보면 비교분석된 배양려액항원(培養慮液抗原)의 조성에 있어서 균주간(菌株間)에 정성(定性) 및 정량적(定量的) 차이가 있음을 알수 있었다. 혈청학적(血淸學的) 반응력(反應力)과 특이성(特異性)이 비교적 높은 항원성분(抗原成分)을 동정(同定)하기 위해 그러한 항원들이 비교적 많이 함유된 AFG7을 선택하였다. 전기영동(電氣泳動)으로 분리하여 nitrocellulose paper로 전이흡착(轉移吸着)시켜 A. fumigatus나 기타 진균항원(眞菌抗原)에 양성침강항체(陽性沈降抗體)(면역확산시험(免疫擴散試驗)에서)를 가진 혈청과 반응시킨 결과 적어도 36개의 항원성분이 검출되었다. 그러나 혈청학적 진단가치가 있는 항원성분은 4개 정도에 불과했다. 특이성과 반응력이 가장 높아 표준항원(標準抗原)에 반드시 함유되어야 할 것으로 보는 항원성분은 분자량(分子量)이 82 KD 정도되는 항원이었고 그 외에 11 KD, 26 KD, 30 KD 및 31 KD 등도 우수한 항원성분으로서 앞으로 더 연구검토되어야 할 것으로 본다. 반응력이 큰 항원이면 Coomassie청(靑)에는 흐리게 염색되어도 immunoblots상에는 짙게 염색되는데 비해 반응력이 약한 항원은 그와 반대현상을 나타내어 immunoblotting 분석법이 항원의 반응력과 특이성 관찰에 매우 유용함을 알 수 있다. 많은 항원성분이 균종특이(菌種特異) 항원결정기(抗原決定基)와 함께 광범한 균군(菌群)에 분포하는 항원결정기(抗原決定基)도 가지고 있었다.

  • PDF

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

공공 주택건설사업의 현장환경관리 업무요소 도출 및 수행주체 분석 (Identification of On-site Environmental Management Factors and Analysis of Responsible Parties in Public Housing Construction Sites)

  • 손정락;송상훈;전명훈;박성식
    • 토지주택연구
    • /
    • 제4권4호
    • /
    • pp.383-393
    • /
    • 2013
  • 저탄소 녹색성장 및 친환경 트렌드는 미래 지구환경 보존의 핵심 개발지표이며, 정부도 제3차 건설환경기본계획을 발표하면서 녹색건설기술 및 고품질 건설환경 구현을 위해 체계적이고 다양한 추진방향을 제시하고 있다. 그러나 아직까지도 생산단계인 건설과정에서의 저탄소 및 친환경적 노력은 미흡한 실정이다. 이에 본 연구에서는 공공 주택건설 현장의 친환경성 제고를 위해 기본적으로 시행되어야 할 활동인 현장의 환경관리 업무요소를 도출하고, 각각의 업무요소에 대한 합리적 수행주체와 프로세스를 제시하였다. 본 연구결과는 향후 체계적인 현장 환경관리를 위해 필요한 수행업무를 파악하고, 수행주체 및 역할분담, 업무수행 프로세스를 합리화하는데 매우 유용한 자료가 될 것이다. 본 연구결과를 실무에 적용하기 위해서는 연구결과로 제시하고 있는 단위업무의 수행주체 및 수행프로세스별 명확한 업무분장에 대한 협의가 반드시 필요하며, 이와 아울러 환경관련 각종 제도 및 기준 현실화가 필수적이다. 이러한 적극적 이행노력과 더불어, 향후 환경관리활동 수행과정 및 결과에 대한 평가방법, 환경요인별 환경문제 발생 시의 기술적 해결방법에 대한 검토도 추가적으로 연구되어야 할 것이다.

Bioequivalence Evaluation of Two Brands of Zolpidem Tartrate 10 mg Tablets(Zanilo and Stilnox) in Healthy Male Volunteers

  • Ryu, Ju-Hee;Lee, Heon-Woo;Lee, Hyun-Su;Kang, Il-Mo;Seo, Ji-Hyung;Kang, Jin-Yang;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권5호
    • /
    • pp.343-348
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two zolpidem tartrate tablets, Stilnox tablet(Sanofi-aventis Korea, reference product) and Zanilo tablet(ChoDang Pharm Co., Ltd., Korea, test product), according to the guidelines of Korea Food and Drug Administration(KFDA). After adding an internal standard(cimetropium), 250 ${\mu}L$ plasma samples were extracted using 1.3 mL of ethyl acetate. Extracted compounds were analyzed by HPLC with triple-quadrupole mass spectrometry. This method for determination of zolpidem is proved accurate and reproducible with the limit of quantitation of 1 ng/mL in human plasma. Twenty-four healthy male Korean volunteers received each medicine at the zolpidem tartrate dose of 10 mg in a $2{\times}2$ crossover study. There was one-week washout period between the doses. Plasma concentrations of zolpidem were monitored for over a period of 8 hr after the administration. $AUC_{0-t}$(the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{0-t}$ and $C_{max}$. No significant sequence effect was found for all of the bio-availability parameters indicating that the crossover design was properly performed. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25(e.g., log 0.92-log 1.06 for $AUC_{0-t}$, log 0.96-log 1.13 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that Zanilo tablet is bioequivalent to Stilnox tablet.

요인분석을 이용한 기본공간정보 선정에 관한 연구 (A Study on Selecting Geospatial Framework Data Using Factor Analysis)

  • 최병남;이지훈;박진식;강인구
    • Spatial Information Research
    • /
    • 제23권5호
    • /
    • pp.53-64
    • /
    • 2015
  • 디지털시대에 다양한 분야에서 공간정보를 공유하기 위해 여러 국가들은 NSDI를 구축하고 있다. NSDI의 중요한 요소 중 하나는 기본공간정보로 다양한 분야에서 공통으로 공유되는 공간정보(콘텐트)를 의미한다. 여러 연구들이 공간정보 분야 전문가, 사용자 등을 대상으로 한 선호빈도 조사, 외국 사례조사 등으로 기본공간정보 구성항목을 제안하고 있다. 그러나 이와 같은 방법은 기본공간정보 항목 선정결과에 대한 객관적인 검증이 미흡하다. 본 연구는 요인분석을 이용한 통계적 검증을 통해 다양한 분야에서 공통으로 공유되는 실체로 공간정보(콘텐트)가 무엇인지를 분석한다. 이를 위해 우리나라에서 가장 많이 사용되는 국가기본도의 중분류 레이어 104개와 그 외에 다양한 분야에서 많이 사용하는 지적, 영상 등을 포함해 총 109개 레이어의 활용행태를 조사한다. 조사내용은 기본공간정보 활용행태의 특성인 배경자료, 기준자료, 기초자료로서 각 레이어가 사용되는 정도이다. 그리고 이외 다른 목적으로 사용빈도가 높은 기타의 경우를 조사한다. 요인분석 결과 각 활용행태에 따라 5-7개 요인집단들이 도출되었다. 각 활용행태의 요인집단에 대한 분산분석 결과 집단의 평균값 사이에 통계적으로 유의한 차이가 있는 것으로 나타났다. 그리고 각 활용행태에서 평균값이 높은 요인집단의 레이어 항목들은 거의 동일하다고 할 만큼 유사하다. 이와 같은 결과를 바탕으로 본 연구는 교통(도로, 철도), 건물, 수계, 고도, 행정구역, 영상, 측량기준, 지적 등 8개의 주제를 중심으로 기본공간정보 구성체계를 제안한다. 본 연구에서 제안한 기본공간정보를 구성하는 주제정의는 공간정보 공유체계를 구축하는 시작의 단추로 의미가 있다. 제안된 기본공간정보가 다양한 분야에서 공유되기 위해서 실제 표준 형태로 구축되고 유통되는 체계를 갖추어야 하며, 이와 관련된 연구들이 이루어져야 한다.

서울시 대기관측망을 중심으로 부유분진 기준농도 초과자료를 이용한 시공간적 경향성 비교 연구 (The Patterns of the PM Air Quality Guidance Level in Seoul during 1990~2000)

  • 최여진;김민영;김기현
    • 한국지구과학회지
    • /
    • 제24권3호
    • /
    • pp.190-204
    • /
    • 2003
  • 본 연구에서는 서울시에 의해 운영되는 서울시내 31개 지역의 대기오염 자동측정망에서 1990년부터 2000년까지 11년 동안 측정한 자료 중, TSP와 PM$_{10}$에 대한 대기환경기준을 초과한 자료만을 선택적으로 분리한 후 여러 가지 통계적인 분석을 수행하였다. 이러한 연구목적에 맞추어, 각 토지 이용 상태별로 환경기준을 초과한 분진농도의 경향성을 비교해 본 결과, TSP의 경우 초과농도의 전반적인 발생분포가 녹지, 주거, 상업, 준공업지역 순서로 증가하는 양상을 보여주었다. 준공업 지역에서 351.0${\pm}$35.9${\mu}$g m$^3$로 가장 높은 초과농도를 보였다. PM$_{10}$의 초과농도는 주거지역에서 182.9${\pm}$42.4${\mu}$g m$^3$의 최고농도를 보이며, 초과농도분포는 준공업, 상업, 녹지, 주거지역 순서로 증가하는 양상을 보인다. 발생빈도수를 각 지점별 측정망수로 나누어 준 결과 주거지역에서 21회로 다른지역에 비해 높은 초과빈도수를 보였다. 이들 초과농도자료들만에 국한시켜 시간적 주기성을 분석한 결과에 따르면, 일반적으로 관측되는 부유분진 자료들과 차별화 된 경향성이 어느 정도 확인되었다. 특히 계절적인 주기로 구분하였을 때, 일반농도자료는 PM$_{10}$과 TSP 모두 겨울철에 가장 큰 농도를 보인데 반해, 초과농도는 다른 양상을 보여주었다. 이러한 연구결과, PM$_{10}$의 연도별 경향성에서 가장 주목할 점은 측정이 시작된 1995년 이후 초과농도의 크기가 지속적으로 감소함에도 불구하고, 그 발생빈도수는 최근에 들어 괄목할 만큼 증가하고 있다는 점을 들 수 있다.