• Title/Summary/Keyword: reference standard

Search Result 2,153, Processing Time 0.036 seconds

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.

Genetic Analysis of Natural Microflora in the Stored Joraengyi Rice Cake and Their Capability of Propionic Acid Production (조랭이 떡에 존재하는 자연균총 유전자 군집분석 및 천연유래 프로피온산 생성능 분석)

  • Park, Hee-Dae;Chae, Jung-Kyu;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.375-382
    • /
    • 2018
  • This study was conducted to analyze the microbial community and propionic acid production ability of natural microflora in the rice cakes. Genetic analysis of natural microflora in Jorangyi rice cake was performed to select propionic acid - producing bacteria. Selected propionic acid-producing bacteria were cultivated in TSB (tryptic soy broth) supplemented with glucose, and growth characteristics were analyzed by temperature and production of propionic acid was analyzed by gas chromatography (GC-FID). Linearity, detection limit, quantitative limit, and recovery rate were measured to verify propionic acid assay. A total of 98 microbial strains were detected from microflora of Joraengyi rice cake that grew after expiration of shelf life. Lactobacillus casei group accounted for 50.48% and Lactobacillus buchneri was 29.60%. Propionic acid - producing bacteria were Propionibacterium thoenii, P. cyclohexanicum, Propionibacterium_uc, P. jensenii, and P. freudenreichii. Natural bacteria and Lactobacillus spp. did not produce propionic acid during 14 days but P. cyclohexanicum, P. freudenreichii subsp. Shermanii, P. thoenii and P. jesenii produced $263.47{\mu}g/mL$, $338.90{\mu}g/mL$, $325.43{\mu}g/mL$ and $222.17{\mu}g/mL$ during 4 days and 2,462.02 and 2,904.78, 2,220.64, $3,519.17{\mu}g/mL$ during 14 days. As a result of this study, it was affirmed that the natural microflora of Joraengyi rice cake during storage can produce propionic acid from natural sources even if a high concentration of propionic acid is not intentionally added. Because of characteristics of rice cake composed of starch and glucose. This study will be used as a recognition criterion to detect natural preservatives such as propionic acid in starchy foods such as rice cakes and as reference standard safety management data.

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Study on the Establishment of Project Duty of Water and Facility Capacity in Upland Irrigation - On the Estimation of Duty of Water for the Upland Crops by the Measurement of Evapotranspiration - (밭 관개의 계획용수량 및 시설용량의 정립에 관한 연구 -증발산량 실측에 의한 밭용수량의 추정에 관하여-)

  • 김시원;김선주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.4
    • /
    • pp.23-44
    • /
    • 1988
  • The evaportranspiration of upland crops was measured by four types of lysimeter and water consumption characteristics together with the optimum irrigation point by the crops was defind. Among the evapotranspiration estimation formulas, the constant of wind function in the modified Penman equation was corrected to agree with the meteorological conditions of Korea. The evapotranspiration of the crops in the project standard year was estimated according to the cropping system of the project area in Chungju, and from the estimated evapotras - spiration, net duty of water per one time and irrigation in tervals were investigated. The results obtained are summarized as follows: 1. The evapotranspiration of the same crop measured at the same plot was slightly different by the lysimetric methods, and among the four types of lysimeter, the accuracy of the floating lysimeter was the highest. 2. The yields among the watering treatments showed the significance of 5% in the expe- riment with red cabbage and Chinese cabbage, and significance of 1% in the crisphead lettuce, and the optimum irrigation point for the tested crops was defined ad pF 2.0 by the least squre difference test. 3. The evapotranspiration of the crops in the mid-season stage showed maximum among the growing stages, and the average daily evapotranspiration by the crops over the growing seasons of cabbage, crisphead lettuce, Chinese cabbage, summer cucumber, tornato, salary and autumn cucumber was 4.18mm, 4.77mm, 3.9qrnm, 5.68mnn, joonim, 4.26mm and 3.3qrnn, respectively. 4. From the investigated soil moisture extration pattern(SMEP) of the crisphead lettuce, cucumber and tomato, the proportion of the first layer in the initial stage showed over so%, and the SMEP of the lowest fourth layer during the late-season stage in the experiment cabbage and Chinese cabbage was 15.8% and 16.9, respectively, with showed that the root elongated th the lowest soil layer. 5. The total available moisture(TAM) of clay loam was 21.2-23.3mm and that of sandy loam was 16.1 - 19.0mm under the optimum irrigation point of pF. 2.0, and the total readily available moisture( TRAM) of the crops cultivated in the clay loam soil was larger than that cultivated in the sandy loam soil, and the TRAM during the mid-and late-season were larger than that of the inital and crop development stage. 6. The estimated evapotranspration by the corrected Pennam equation, whkh corrected the constant of the wind function in the modified Penman equation, was nearly agreed with the actually measured evaporanspiration of grass. 7. Among the several evaportranspiration estimation methods, the evapotranspiration es- timated by the corrected Pennam equation was closed to the actual evapotranspiration of reference crop (grass) evapotranspiration, therefore it is suggested to use the corrected Penman equation to determine the duty of water of corps. 8. The average crop coefficient (Kc) of cabbage by the corrected Penman equation was 0.94 and that of crisphead lettuce, summer cucumber, tomato, salary, Chinese cabbage and autumn cucumber was 1.07, 1.22, 1.02, 1.01, 1.35, 1.09, respectively 9. The estimated total evapotranspiration of cabbage in the project area( Chungju) by the corrected Penman equation was 223.9mm and that of crisphead lettuce, Chinese cabbage, summer cucumber, tomato, salary and auturun cucumber was 215.7mm, 205.9mm, 359.Omrn, 300.9mm, 332.lmm and 202.7mm, respectively. 10. The net duty of water per one time of the crops cultivated in the sandy loam soil, and the net duty of water per one time in the mid-season & late-season showed larger than that of the initial stage. 11. The shortest irrigation interval of cabbage in the project area was 4.2 days, and that of crisphead lettuce, Chinese cabbage, cucumber, tomato and salary was 1.2days, 2.3days, 1.8days, 2.2days and 2.7days, respectively.

  • PDF

A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement (PM10 질량농도 측정을 위한 시료채취기의 비교 연구)

  • Park, Ju-Myon;Koo, Ja-Kon;Jeong, Tae-Young;Kwon, Dong-Myung;Yoo, Jong-Ik;Seo, Yong-Chil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A PM10 (aerodynamic diameter${\leq}$10 ${\mu}m$) sampler is used to quantify the potential human exposure to suspended particulate matter (PM) and to comply with the governmental regulation. This study was conducted to compare and evaluate the same PM10 cutpoint and different slopes between United States Environmental Protection Agency (USEPA) PM10 sampling criterion and American Conference of Governmental Industrial Hygienists/$Comit\acute{e}$ $Europ\acute{e}en$ de Normalization/International Organization for Standardization thoracic PM10 sampling criterion through theory and experiment. Four PM10 samplers according to the USEPA criterion and one RespiCon sampler in accordance with the thoracic PM10 criterion were used in the present study. In addition, one DustTrak monitor was used to measure real time PM10 mass concentrations. All six aerosol samplers were tested in a PM generation chamber using polydisperse fly ash. Theoretical mass concentrations were calculated by applying the measured particle size distribution characteristics (geometric mean = 6.6 ${\mu}m$, geometric standard deviation = 1.9) of fly ash to each sampling criterion. The measured mass concentrations through a chamber experiment were consistent with theoretical mass concentrations in that a RespiCon sampler with the thoracic PM10 criterion collected less PM than a PM10 sampler with the USEPA criterion. The overall chamber experiment results indicated, when a PM10 sampler was used as a reference sampler, that (1) a RespiCon sampler had a normalizing factor of 1.6, meaning that this sampler underestimated an average 60% of PM10 mass sampled from a PM10 sampler, and (2) a DustTrak real-time monitor using a PM10 inlet had a calibration factor of 2.1.

Evaluation of Neoadjuvant Chemotherapy Effect in Osteosarcoma (골육종에서 술전 항암화학요법의 효과 판정)

  • Joo, Min Wook;Kang, Yong-Koo;Yoo, Ie Ryung;Choi, Woo Hee;Chung, Yang-Guk;Kim, Dong-Hyun;Kang, Jin-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • Purpose: Various diagnostic imaging modalities have been used to evaluate the effect of neoadjuvant chemotherapy for osteosarcoma early and noninvasively. We evaluated the effectiveness of imaging studies of plain radiographs and positron-emission tomography/computed tomography (PET/CT) in predicting neoadjuvant chemotherapy effect for osteosarcoma and tried to establish a general principle in interpretation of PET/CT parameters. Materials and Methods: Eighteen patients who underwent two cycles of neoadjuvant chemotherapy and surgical excision for osteosarcoma were enrolled. There were 13 males and 5 females, with a median age of 19 (11-63) years. Fifteen patients of 18 had the American Joint Committe on Cancer (AJCC) stage IIB. They had plain radiographs and PET/CT before and after neoadjuvant chemotherapy. The resected tumor specimens were pathologically examined to determine histological response grade using a conventional mapping method. Statistical analysis was performed to evaluate the correlation between histopathological necrosis rate, and radiographic finding category, post-chemotherapy maximum standardized uptake value (SUVmax), average standardized uptake value and metabolic tumor volume (MTV) as well as reduction rates of them. Results: Eight patients were good responders to neoadjuvant chemotherapy based on histological evaluation. Median SUVmax reduction rate was 73 (23-77) % in good responders and 42 (-32-76) % in poor responders. Median MTV reduction rate was 93.5 (62-99) % in good responders and 46 (-81-100) % in poor responders. While radiographic finding category was not different according to histological response (p=1.0), SUVmax reduction rate was significantly different (p=0.041). Difference in MTV reduction rates approached statistical significance as well (p=0.071). Conclusion: While radiographic finding category was not reliable to assess neoadjuvant chemotherapy effect for osteosarcoma, reduction rate of SUVmax was a useful indicator in this study. As parameters of PET/CT can be influenced by various factors of settings, different centers have to make an effort to establish their own standard of judgement with reference of previous studies.

A Posteroanterior Cephalometric Study on Craniofacial Proportions of Koreans with Normal Occlusion (한국인 정상 교합자의 정모 두부 방사선 사진을 이용한 안모비율에 관한 연구)

  • Baik, Hyoung-Seon;Yu, Hyung Seog;Lee, Kie-Joo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.643-659
    • /
    • 1997
  • For the total treatment of skeletal malocclusions, 3-dimensional evaluation and diagnosis are essential. Although anteroposterior discrepancies can be evaluated through various methods, the satisfactory methods for evaluations of facial asymmetry and transverse discrepancies are yet to be found. The adequate diagnosis and treatment of transverse discrepancies may be more important in the maintenance of functional occlusion as well as for the stability of results obtained from orthognathic surgery than the anteroposterior or vertical discrepancies. Since the soft tissue effects from the transverse discrepancies may not be pronounced, especially when combined with anteroposterior or vertical discrepancies which have prominent characteristics, the differentiation of their effects may be difficult from visual inspection alone. Therefore it is essential that the normal facial proportions would be established from the posteroanterior cephalometry as a reference for the accurate diagnosis and treatment. The present study evaluates 76 subjects from Yonsei University freshmen with normal facial symmetry and occlusion. Posteroanterior cephalograms were taken from the subjects and the normal values and facial proportions are obtained. The results are as follows. 1. The transverse and vortical values from posteroanterior cephalometry and their ratio, with means and standard deviations are calculated. 2. The ratio of vertical values to transverse values is 0.837 (male 0.836, female 0.841). 3. The Proportion of maxillary and mandibular widths is 0.747 (male 0.745, female 0.752), with statistically significant correlation. 4. Various degree of significant correlations are observed in the following craniofacial widths; (Cranial width, Bizygomaticofrontal suture width, Facial width, Maxillary width, Upper & Lower Intermolar width, Mandibular width). 5. Although the facial height as well as other line measurements increase as the facial widths increase, angle measurement ($Bj\ddot{o}rk$ Sum, Mandibular Plane Angle, Gonial Angle), decreases and posterior to anterior facial height ratio increases, therefore indicating the tendency for a brachycephalic facial type. These results may be used as references for the treatment planning in orthognathic and orthodontic treatments for the dentofacial deformity patients.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.