• Title/Summary/Keyword: reference sample

Search Result 855, Processing Time 0.079 seconds

Quality Characteristics of Muffins containing Maesangi Powder Abstract (매생이가루 첨가량에 따른 머핀의 품질특성)

  • Seo, Eun-Ok;Kim, Kwang-Oh;Ko, Seong-Hye;Park, Jin-Hee;Han, Eun-Ju;Cha, Kyung-Ok;Ko, Eun-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.22 no.3
    • /
    • pp.414-421
    • /
    • 2012
  • Moisture content of muffin tended to increased as increasing mixing rate of maesangi. For crude protein, sample group of 9% replaced by maesangi powder was the highest. For crude fat and crude ash, there was no significant difference among sample groups. The average height of muffin was 4.7 cm, but was no significant difference among sample groups. Volume of muffin has been gradually increased as increasing mixing rate of maesangi powder, but was no significant difference among sample groups. From the SEM (scanning electron microscope) result, thick cell wall and rough blowholes were appeared. L-, a and b-values of muffin was declined as per increase of mixing rate of maesangi powder. Hardness was inclined as per increase of mixing rate of maesangi powder. There were significant differences between sample groups and reference group for adhesiveness, springiness and cohesiveness, but was no significant difference among sample groups. For gumminess, sample group of 9% replaced by maesangi powder was the highest, but there were no significant difference from sample groups of 3% and 6% replaced by maesangi powder. Chewiness was inclined as per increase of mixing rate of maesangi powder, and sample group of 9% replaced by maesangi powder was the highest. From sensory test result, sample group of 9% replaced by maesangi powder was the highest for color, and there were significant differences among sample groups. Sample group of 6% replaced by maesangi powder was the highest for flavor and taste, and there were significant differences among sample groups. Sample groups of 6% and 9% replaced by maesangi powder were the highest for texture. Sample group of 9% replaced by maesangi powder was the highest for overall preference. From all these results, the most suitable one would be the sample group of 9% replaced by maesangi powder.

A Study on the Self-absorption Correction Method of HPGe Gamma Spectrocopy Analysis System Using Check Source (Check Source를 이용한 HPGe감마핵종분석시스템의 자체흡수 보정방법 연구)

  • Jeong-Soo, Park;Hyo-Jin, Lim;Hyun-Soo, Seo;Da-bin, Jang;Myoung-Joon, Kim;Sang-Bok, Lee;Sung-Min, Ahn
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.523-529
    • /
    • 2022
  • Gamma spectroscopy analysis is widely used for radioactivity analysis, and various factors are required for radioactivity calculations. Among the factors, K3 for each sample significantly influences the results. The previous methods of correcting the self-absorption effect include a computational simulation method and a method that requires making a CRM(certified reference material) identical to the sample medium. However, the above methods have limitations when used in small institutions because they require specialized program utilization skills or high manufacturing costs and large facilities. The aim of this study is to develop a method that can be easily and rapidly applied to radioactivity analysis. After filling the beaker with water, we placed the radiation source in a uniform position and used the measured value as the benchmark. Next, a correction factor was derived based on the difference in the radiation source count of the benchmark and the identically measured sample. For the radiation source, Eu-152, which emits a broad range of energy within the measurement range of gamma rays, and Cs-134 and Cs-137, which are indicator nuclides in environmental radiation analysis, were used. The sample was selected within the density range of 0.26-2.11 g/cm3, and the correction factor was derived by calculating the count difference of each sample compared to the reference value of water. This study presents a faster and more convenient method than the existing research methods for determining the self-absorption effect correction, which has become increasingly necessary.

The Housework Sharing between Husbands and Wives With Special Reference to Wives' Jobs (부인의 취업유무와 직종에 따른 부부의 가사수행)

  • 이미숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.1
    • /
    • pp.205-220
    • /
    • 1997
  • The purpose of this study is to explore the housework sharing between husbands and wives with special reference to wives' jobs, Using couple data from a sample of 370 dual-earner couples and 250 husband-only employed couples multiple regression analysis was used. Major findings were as follows: 1) Husbands of the dual-earner couples participated in housework a little more than husbands of the husband-only employed couples did. 2) The husbands whose wives' jobs are office workers tended to share housework more than the husbands whose wives' jobs are professionals or blue collars did. 3) Among the variables which significantly affect housework sharing husbands' sex role attitude is the most influential factor and each partner's working hours a week has also significant effect. I suggested that more studies are needed to explore the relationship between the housework sharing and marital quality in order to identify and to lessen the stresses between husband and wife.

  • PDF

Characterization of Test Substance in the GLP (GLP 시험에서의 시험물질 특성파악)

  • Lee, Eun-Jung;Song, Kyung-Seuk;Yu, Il-Je
    • Toxicological Research
    • /
    • v.23 no.2
    • /
    • pp.173-177
    • /
    • 2007
  • The GLP contains specific language concerning characterization of the test, control and reference substances used in toxicity studies. This paper will describe and discuss what types of documents are required to support test/reference substance characterization under GLP system. The purpose of this article is to present an overview of data needed in the characterization package that will adequately define the substance. Most sponsors use a certificate of analysis (COA) to communicate the test sub-stance characterization status information to the contracting research organizations. The COA should provide the test $material^{\circ}{\phi}s$ characterization results, substance storage requirements, expiration dates, verification of the collection of the retention sample, archival location of the data to support the characterization and GLP compliance status of the characterization.

Applications of ICP-MS to the Determination of Trace Np and Pu in Environmental Samples with Extraction Chromatography

  • Ji, Yanqin;Li, Jinying;Luo, Shanggeng
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.182-190
    • /
    • 2004
  • An unique extraction chromatographic column (TOA: Tri-n-octylamine on Teflon powder) with a two-stage sample loading was prepared to separate Np and Pu from the environmental matrix. Np and Pu were efficiently retained in 4 M $HNO_3$ medium on the column and easily eluted with 0.02 M oxalic acid in 0.16 M HNO$_3$at $95^{\circ}C$. The separated solutions were free from most of the matrix elements and were aspirated into the ICP-MS directly. The decontamination factor for 238U is more than 104. The instrumental detection limit for 237Np was 0.46 pg mL-l ($1.2{\times}10_{-5}$Bq mL-l), and for 239Pu was 0.48 pg mL-l ($1.1{\times}10_{-3}$ Bq mL-l). The feasibility for the determination of both elements was proved by analysing IAEA-135 reference samples, the measured values agreed with the recommended reference value.

  • PDF

Optimal designing of skip lot sampling plan of type SkSP-2 with double sampling plan as the reference plan under generalized exponential distribution

  • Suresh, K.K.;Kavithamani, M.
    • International Journal of Reliability and Applications
    • /
    • v.15 no.2
    • /
    • pp.77-84
    • /
    • 2014
  • In this paper, a optimal designing methodology is proposed to determine the parameters for skip-lot sampling plan of type SkSP-2 plan with double sampling plan as reference plan, when the lifetime of the product follows generalized exponential distribution. The two points on the operating characteristic curve approach are used to find the optimal parameters for the proposed plan. The plan parameters are determined so as to minimize the average sample number subject to satisfying simultaneously both producer and consumer risks at the acceptable and limiting quality levels respectively.

  • PDF

Development of Matching Priors for P(X < Y) in Exprnential dlstributions

  • Lee, Gunhee
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.4
    • /
    • pp.421-433
    • /
    • 1998
  • In this paper, matching priors for P(X < Y) are investigated when both distributions are exponential distributions. Two recent approaches for finding noninformative priors are introduced. The first one is the verger and Bernardo's forward and backward reference priors that maximizes the expected Kullback-Liebler Divergence between posterior and prior density. The second one is the matching prior identified by matching the one sided posterior credible interval with the frequentist's desired confidence level. The general forms of the second- order matching prior are presented so that the one sided posterior credible intervals agree with the frequentist's desired confidence levels up to O(n$^{-1}$ ). The frequentist coverage probabilities of confidence sets based on several noninformative priors are compared for small sample sizes via the Monte-Carlo simulation.

  • PDF

Implementation of the single channel adaptive noise canceller using TMS320C30 (TMS320C30을 이용한 단일채널 적응잡음제거기 구현)

  • Jung, Sung-Yun;Woo, Se-Jeong;Son, Chang-Hee;Bae, Keun-Sung
    • Speech Sciences
    • /
    • v.8 no.2
    • /
    • pp.73-81
    • /
    • 2001
  • In this paper, we focus on the real time implementation of the single channel adaptive noise canceller(ANC) by using TMS320C30 EVM board. The implemented single channel adaptive noise canceller is based on a reference paper [1] in which it is simulated by using the recursive average magnitude difference function(AMDF) to get a properly delayed input speech on a sample basis as a reference signal and normalized least mean square(NLMS) algorithm. To certify results of the real time implementation, we measured the processing time of the ANC and enhancement ratio according to various signalto-noise ratios(SNRs). Experimental results demonstrate that the processing time of the speech signal of 32ms length with delay estimation of every 10 samples is about 26.3 ms, and almost the same performance as given in [1] is obtained with the implemented system.

  • PDF

Implementation of the Real-time Measurement System of Receiver Sensitivity for a Laser Range Finder (레이저 거리 측정기용 광 검출기 수신 감도 실시간 측정 시스템 구현)

  • Lee, Young-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.108-111
    • /
    • 2016
  • We propose the method for measuring sensitivity of optical receiver of a long-range laser range finder in real-time. The sensitivity of the detector can be calculated using the detected voltage of the reference sensor, the area of the reference sensor and the transmittance ratio of neutral density filters. To evaluate the performance of the proposed method, we implemented a system and performed experiments. As a result, this system can be measured from 2nW to $113{\mu}W$. With this system, we measured the sensitivity of 37nW and 7nW with PIN PD and APD sample, respectively. This system has the advantage for the performance test of an optical sensor module in the long-range laser range finder.

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF