• Title/Summary/Keyword: reference range

Search Result 1,776, Processing Time 0.032 seconds

A Study on Real-Coded Adaptive Range Multi-Objective Genetic Algorithm for Airfoil Shape Design (익형 형상 설계를 위한 실수기반 적응영역 다목적 유전자 알고리즘 연구)

  • Jung, Sung-Ki;Kim, Ji-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.509-515
    • /
    • 2013
  • In this study, the real-coded adaptive range multi-objective genetic algorithm code, which represents the global multi-objective optimization algorithm, was developed for an airfoil shape design. In order to achieve the better aerodynamic characteristics than reference airfoil at landing and cruise conditions, maximum lift coefficient and lift-to-drag ratio were chosen as object functions. Futhermore, the PARSEC method reflecting geometrical properties of airfoil was adopted to generate airfoil shapes. Finally, two airfoils, which show better aerodynamic characteristics than a reference airfoil, were chosen. As a result, maximum lift coefficient and lift-to-drag ratio were increased of 4.89% and 5.38% for first candidate airfoil and 7.13% and 4.33% for second candidate airfoil.

The Relocation Effect of Observation Station on the Homogeneity of Seasonal Mean of Diurnal Temperature Range (기상관측소의 이전이 계절평균 일교차의 균질성에 미치는 영향)

  • Kim, Ji-Hyun;Suh, Myoung-Seok;Hong, Soon-Hee
    • Atmosphere
    • /
    • v.20 no.4
    • /
    • pp.437-449
    • /
    • 2010
  • The relocation effect of observation station (REOS) on the homogeneity of seasonal mean of maximum and minimum temperature, diurnal temperature range (DTR) and relative humidity (RH) was investigated using surface observation data and document file. Twelve stations were selected among the 60 stations which have been operated more than 30 years and relocated over one time. The data from Chunpungryeong station were used as a reference to separate the impacts of station relocation from the effects caused by increased green house gases, urbanization, and others. The REOS was calculated as a difference between REOS of relocated station and REOS of reference station. Although the REOS is clearly dependent on season, meteorological elements, and observing stations, statistically significant impacts are found in many stations, especially the environment of observing station after relocation is greatly changed. As a result, homogeneity of seasonal mean of meteorological elements, especially DTR and RH, is greatly reduced. The results showed that the effect of REOS, along with the effect of urbanization, should be eliminated for the proper estimation of climate change from the analysis of long-term observation data.

Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique (Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

The Reliability of Kinematic Analysis for Distal Upper Extremity in Normal Person (정상인의 상지 원위부에 대한 운동학적 분석의 신뢰도)

  • Byun, Jae-Hyun;Hong, Wan-Ki
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Purpose: To evaluate statistical differences among three measurements of range of motion (ROM) with Rapael Smart Glove (RSG) group 1, 2 and manual goniometer group. To investigate reference value of the kinematic analysis for range of motion (ROM) of distal upper extremity with Rapael Smart Glove (RSG). Methods: Sixteen normal persons without limitation of motion (LOM) enrolled in the study. The study was performed at two separate times and by two investigators on 16 normal adults. We compared ROM with RSG for measuring joint angles. We compared degrees of forearm supination/pronation, wrist flexion/extension and radial deviation/ulnar deviation during ROM of 16 participants using RSG. After one week, degrees of each motion were measured in the same way by other investigator to evaluate the reliability. Results: Statistical differences among three groups were showed. Most results of paired t-test between two RSG groups were over 0.05 and exceptions are supination, extension, and finger %. Conclusion: Our findings demonstrate that ROM of normal persons obtained by kinematic analysis with RSG are not valid as normal reference value for distal upper extremity motion. But, the reliability of between two RSG groups was showed with paired t-test and Pearson's correlation except supination, extension and finger %.

Design and Fabrication of a Multiple Scattering Points Discriminator for a Simulated Target Measurement using a High Range Resolution RADAR (고해상도 레이다를 이용한 모의 대상물 측정용 다중산란점 분별기의 설계 및 제작)

  • Jeong, Hae-Chang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.323-330
    • /
    • 2018
  • In this paper, design and fabrication of a MSP(Multiple Scattering Points) discriminator for a simulated target measurement using a HRR(High Range Resolution) RADAR are described. The MSP discriminator is designed to provide a reference signal at the installed point on the simulated target in an outdoor test. The MSP discriminator is designed to have a remote control function that can turn the MSP discriminator on and off when the target moves to a remote location. While the MSP discriminator is off, the MSP discriminator is designed to be small enough not to spoil the target's unique RCS. The MSP discriminator consists of RF components in the Ku-band. In order to prevent spreading of the signal, a cable were added to the MSP discriminator to have an appropriate feedback loop delay considering the resolution of the RADAR. The fabricated MSP discriminator provided a reference scattering point as an RCS of approximately 1 dBsm. As a result, by using the MSP discriminator, the physical scattering points of the target were clearly identified in the measured signals with the RADAR.

Design and Implementation of a Readout Circuit for a Tactile Sensor Pad Based on Force Sensing Resistors (FSR로 구성된 촉각 센서 패드용 Readout 회로의 설계 및 구현)

  • Yoon, Seon-ho;Baek, Seung-hee;Kim, Cheong-worl
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.331-337
    • /
    • 2017
  • A readout circuit for a tactile sensor pad based on force sensing resistors was proposed, which was composed of an analog signal conditioning circuit and a digital circuit with a microcontroller. The conventional signal conditioning circuit has a dc offset voltage in the output signal, which results from the reference voltage applied to the FSR devices. The offset voltage reduces the dynamic range of the circuit and makes it difficult to operate the circuit under a low voltage power supply. In the proposed signal conditioning circuit, the dc offset voltage was removed completely. The microcontroller with A/D converter and D/A converter was used to enlarge the measurement range of pressure. For this, the microcontroller adjusts the FSR reference voltage according to the resistance magnitude of FSR under pressure. The operation of the proposed readout circuit which was connected to a tactile sensor pad with $5{\times}10$ FSR array was verified experimentally. The experimental results show the proposed readout circuit has the wider measurement range of pressure than the conventional circuit. The proposed circuit is suitable for low voltage and low power applications.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Fabrication and Performance Evaluation of Zinc Oxide Varistors for the Arresters used for Station System (발변전소 피뢰기용 산화아연소자의 제작 및 성능평가)

  • Cho, Han-Goo;Han, Se-Won;Kim, Suk-Soo;Yoon, Han-Soo;Lee, Un-Yong;O, Cheol-Gyu;Yu, Kun-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.636-639
    • /
    • 2004
  • This paper presents the fabrication and performance evaluation of zinc oxide varistors for the arresters used for station system. ZnO varistors were fabricated with typical ceramic production methods and the structural and electrical characteristics were investigated. All varistors exhibited high density, which were in the range of $5.41{\sim}5.49g/cm^3$. In the electrical properties the reference voltage increased in the range of $4.410{\sim}5.250kV$ with increasing their thickness and the residual voltage exhibited the same trends as the reference voltage. In the long duration current impulse withstand test, E-2 and F-1 samples failed in the two and four shots, respectively, but E-1 and F-2 samples survived 18 shots during the test. Before and after this test, the variation ratio of residual voltage of E-1 and F-2 samples were -0.34% and 0.05%, respectively, which were in the acceptance range of 5%. According to the results of tests, it is thought that if the fabrication process such as insulating coating, sintering condition, and soldering method is improved, these ZnO varistors would be possible to apply to the station class arresters in the new future.

  • PDF

The Apparel Sizing System of Early Adolescent Girls - Focusing on Lower Garments - (청소년 전기 여학생의 하의 치수 규격에 관한 연구)

  • Jeong, Hwa-Yeon;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.5 s.58
    • /
    • pp.671-685
    • /
    • 2005
  • The purpose of this study was to develop a new size range and size interval for early adolescent girls. For this purpose, a total of 529 girls aged between 10 and 14 were measured and data were collected from 42 anthropometric measurements and 41 photographic measurements per a person. SAS 8.1 was used in data analysis including means, standard deviations, and frequency analysis. The stature was divided at 5cm intervals as in KS into 9 sizes from the lowest 130cm to the highest 171cm. If waist circumference were divided at the same intervals, the sizes cannot reflect the body growth of adolescent girls at these ages. Thus this study set intervals between sizes irregularly based on the mean of waist circumference by the type of body shape. Based on the results, this study proposed: for Type A - 6 sizes (140A-58, 145A-54, 145A-62, 150A-58, 150A-62, 155A-62); for Type X- 9 sizes (150X-59, 155X-63, 155X-66, 160X-59, 160X-63, 160X-66, 165X-59, 165X-63, 165X-66): and for Type H - 7 sizes (145H-68, 150H-68, 150H-70, 155H-68, 155H-73, 160H-68, 160H-73). For the sizes selected for each type, reference measurements were decided - centering on items necessary for manufacturing clothes. Reference measurements suggested for lower garments 8 items including waist circumference, hip circumference, slacks length and crotch length. The suggested sizes are distributed in a wider range, so they are considered to be helpful for students to find clothes fitting their bodies.

  • PDF

A case of idiopathic thrombocytopenia in a Yorkshire terrier dog (개 특발성 혈소판감소증 1례)

  • Kim, So-La;Cho, Chang-Seok;Kim, Min-Jae;Kang, Tae-Young;Lee, Joo-Myoung;Park, Hyun Jung;Cheong, Jongtae;Lee, Kyoung-kap;Yun, Young-min
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.475-478
    • /
    • 2007
  • A 4-year-old spayed female, Yorkshire terrier dog with a history of petechial and ecchymotic hemorrhages on the face, trunk and hind limb was referred to Veterinary Medical Teaching Hospital, Cheju National University. The complete blood count revealed a marked thrombocytopenia ($96{\times}10^3/{\mu}l$). The biochemical profile showed only slightly increased glucose. The coagulation profile such as prothrombin time and activated partial thromboplastin time, was within the reference range. In Giemsa staining, there were no endoparasites like as Babesia spp. on the RBC. This case was diagnosed as a idiopathic thrombocytopenia in a Yorkshire terrier dog. She was treated with prednisone (1 mg/kg BW, IM q 12 h) and cephalosporin (10 mg/kg BW, IM, q 12 h). When rechecked on day 6, the platelet was within reference range ($507{\times}10^3/{\mu}l$) and also petechial and ecchymotic hemorrhages on the body were gradually improved without any complications. The dose of prednisone was decreased to 0.5 mg/kg BW, q 24 h. On day 17, we finished treatment because all the clinical signs, blood and serum chemistry were reference range and platelet count was dramatically increased.