• 제목/요약/키워드: reference measurements

검색결과 861건 처리시간 0.025초

Mechanical, durability and microstructure properties of concrete containing natural zeolite

  • Nas, Memduh;Kurbetci, Sirin
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.449-459
    • /
    • 2018
  • Concrete is one of the most widely used construction materials in the world. Producing economical and durable concrete is possible by employing pozzolanic materials. The aim of this study is to underline the possibility of the utilization of natural zeolite in producing concrete and investigate its effects basically on the strength and durability of concrete. In the production of concrete mixes, Portland cement was replaced by the natural zeolite at ratios of 0%, 10%, 15%, and 20% by weight. Concretes were produced with total binder contents of $300kg/m^3$ and $400kg/m^3$, but with a constant water to cement ratio of 0.60. In addition to compressive and flexural strength measurements, freeze-thaw and high temperature resistance measurements, rapid chloride permeability, and capillary water absorption tests were performed on the concrete mixes. Compared to the rest mixes, concrete mixes containing 10% zeolite yielded in with the highest compressive and flexural strengths. The rapid chloride permeability and the capillary measurements were decreased as the natural zeolite replacement was increased. Freeze-thaw resistance also improved significantly as the replacement ratio of zeolite was increased. Under the effect of elevated temperature, natural zeolite incorporated concretes with lower binder content yielded higher compressive strength. However, the compressive strengths of concretes with higher binder content after elevated temperature effect were found to be lower than the reference concrete.

2D 레이저센서와 도로정보를 이용한 Particle Filter 기반 자율주행 차량 위치추정기법 개발 (A Study on Localization Methods for Autonomous Vehicle based on Particle Filter Using 2D Laser Sensor Measurements and Road Features)

  • 안경재;이택규;강연식
    • 제어로봇시스템학회논문지
    • /
    • 제22권10호
    • /
    • pp.803-810
    • /
    • 2016
  • This paper presents a study of localization methods based on particle filter using 2D laser sensor measurements and road feature map information, for autonomous vehicles. In order to navigate in an urban environment, an autonomous vehicle should be able to estimate the location of the ego-vehicle with reasonable accuracy. In this study, road features such as curbs and road markings are detected to construct a grid-based feature map using 2D laser range finder measurements. Then, we describe a particle filter-based method for accurate positional estimation of the autonomous vehicle in real-time. Finally, the performance of the proposed method is verified through real road driving experiments, in comparison with accurate DGPS data as a reference.

Field Measurements of the New CCTV Tower in Beijing

  • Xu, Y.L.;Zhan, S.;Xia, H.;Xia, Y.;Zhang, N.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.171-178
    • /
    • 2013
  • The emergence of a growing number of tall buildings, often with unusual shapes and innovative structural systems, has led to the realization of the need for and the importance of field measurements. The new China Central Television (CCTV) Tower in Beijing is one of tall buildings with a highly unusual shape and a complex structural system, requiring field measurements to identify its dynamic characteristics for the subsequent dynamic analysis of the tower under wind excitation, seismic-induced ground motion and traffic-induced ground motion. The structural system and the finite element model of the CCTV Tower are first introduced in this paper. The computed natural frequencies and mode shapes are then presented as a reference for the field measurement. After introducing the arrangement of the ambient vibration measurement, the field measured natural frequencies and damping ratios of the CCTV Tower are presented and the measured natural frequencies are finally compared with the computed ones. It was found that the structural damping ratios of the CCTV Tower are small and the computed natural frequencies are smaller than the measured ones by about 12~17%.

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

Impact of Multi-GNSS Measurements on Baseline Processing for Control Surveying Applications

  • Pawar, Komal Narayan;Yun, Seonghyeon;Lee, Hungkyu;Nguyen, Dinh Huy
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제10권2호
    • /
    • pp.103-111
    • /
    • 2021
  • A series of experiments have been carried out by using National Geographic Information Institute(NGII)'s Continuously Operating Reference Station (CORS) data with various strategies to analyze the impact of multi-GNSS measurements on baseline processing. The results of baseline processing were compared in terms of ambiguity fixing rate, precision, and hypothesis tests were conducted to confirm the statistical difference. The combination of multi-GNSS measurements has helped to improve ambiguity fixing rate, especially under harsh positioning environments. Combination of GPS, Galileo, BeiDou could get better precision than that of GPS, GLONASS, Galileo, and adding QZSS made the baseline solution's vertical component more precisely. The hypothesis tests have statistically confirmed that the inclusion of the multi-GNSS in the baseline processing enables not only to reduce field observation time length but also to enhance the solution's precision. However, it is of interest to notice that results of the baseline solution are dependent upon the software used. Hence, comprehensive studies should be performed shortly to derive the best practice to select the appropriate software.

Deep Hydrochemical Investigations Using a Borehole Drilled in Granite in Wonju, South Korea

  • Kim, Eungyeong;Cho, Su Bin;Kihm, You Hong;Hyun, Sung Pil
    • 방사성폐기물학회지
    • /
    • 제19권4호
    • /
    • pp.517-532
    • /
    • 2021
  • Safe geological disposal of spent nuclear fuel (SNF) requires knowledge of the deep hydrochemical characteristics of the repository site. Here, we conducted a set of deep hydrochemical investigations using a 750-m borehole drilled in a model granite system in Wonju, South Korea. A closed investigation system consisting of a double-packer, Waterra pump, flow cell, and water-quality measurement unit was used for in situ water quality measurements and subsequent groundwater sampling. We managed the drilling water labeled with a fluorescein dye using a recycling system that reuses the water discharged from the borehole. We selected the test depths based on the dye concentrations, outflow water quality parameters, borehole logging, and visual inspection of the rock cores. The groundwater pumped up to the surface flowed into the flow cell, where the in situ water quality parameters were measured, and it was then collected for further laboratory measurements. Atmospheric contact was minimized during the entire process. Before hydrochemical measurements and sample collection, pumping was performed to purge the remnant drilling water. This study on a model borehole can serve as a reference for the future development of deep hydrochemical investigation procedures and techniques for siting processes of SNF repositories.

Validity of Weight and Height as a Nutritional Status Measurement for Adults in Kuri City

  • Kim, Youngok;Lee, Soon-Young
    • Journal of Community Nutrition
    • /
    • 제1권1호
    • /
    • pp.39-43
    • /
    • 1999
  • Anthropometric measurements, particularly weight and height, are the most commonly employed measures of nutritional status in epidemiologic studies because of their simplicity and ease of collection. However, the usefulness of the anthropometric indicator is controversial. The aim of this study was to evaluate the usefulness of the anthropometric indicator to represent the nutritional status of individual adult in epidemiologic studies. In order to evaluate the usefulness of the anthropometric indicator to represent the nutritional status of individual, the validity in terms of sensitivity and specificity of anthropometric indicators was estimated by comparing the biochemical indicators to the reference indicators. The relative validity of dietary intake indicators was also measured for comparison between the three indicators of biochemistry, anthropometry and dietary assessment. The results showed that sensitivity of weight and height and dietary indicators were 16.7 an 50.5, respectively comparing the reference value of 100 as biochemical indicator in identifying anemic adults. Whereas the sensitivity of weight and height and dietary indicators were 63.6 and 36.4, respectively comparing reference value of 100 in identifying hyperlipidemic individuals(obesity). In conclusion, the validity of weight and height is much lower than that of biochemical indicator, burt weight and height still has some usefulness in identifying anemic individuals. Especially, it is more useful in identifying hyperlipidemic individual adults thant in identifying anemic individuals.

  • PDF

개폐 충격전압 측정용 쉴드 저항분압기의 직각파 특성에 관한 연구 (A Study on the Step Response Characteristics in Shielded Resistor Divider for Switching Impulse Voltage)

  • 김익수;이형호;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.777-784
    • /
    • 1999
  • Since the ultra-high voltage power apparatus are recommended to withstand switching surge generated from the electric power system, the switching impulse voltage is generally used to verify this requirement at the testing laboratories. Recently, the international standard(IEC 60060-2) related to the high voltage measurement techniques is revised requiring a traceability of measuring system for high voltage measurements. In this paper, a reference divider for switching impulse voltage is developed satisfying the revised. IEC standard and the possibility of applications has been investigated. Therefore, the characteristics of the high and low voltage side resistor and the shielding ring have been analyzed including the step response characteristics of the prototype divider. Throughout various efforts, it is confirmed that our measuring device has shown compatible characteristics as a reference divider.

  • PDF

우리나라 육상 중역기점 전이

  • 최광선;옥수석;원지훈
    • 지구물리
    • /
    • 제4권2호
    • /
    • pp.121-131
    • /
    • 2001
  • 2대의 중력계를 이용하여 우리나라의 88개 기상관서 내에 중력 보조점을 설치하고 GPS 측량을 실시하였다. 모든 중력 보조점의 중력치는 부산대학교 내의 중력기준점을 기준으로 측정하여, 향후 새로운 절대중력기점 값으로 쉽게 환산할 수 있도록 하였다. 이러한 중력기준망의 확장은 중력의 측정과 drift 보정 등에 의해 나타나는 오차를 최소화하여 중력 자료의 정밀도를 증대할 것이다. 또한 이 연구 결과는 상대중력계에 이해 계산된 중력 자료의 검증 및 상대중력계의 점검 등에 활용 될 수 있을 것으로 기대된다.

  • PDF

다중 프로브 검사 계측 장비를 위한 단차 표준 인증 물질의 설계 및 제작 (Design and Fabrication of a Step Height Certified Reference Material for Multi-probe Inspection Instruments)

  • 맹새롬;진종한;;김재완;김종안;강주식
    • 한국정밀공학회지
    • /
    • 제28권3호
    • /
    • pp.323-329
    • /
    • 2011
  • Certified reference materials (CRMs) have been used to calibrate surface profilers for reliable measurements. In this paper, we present a newly designed step height CRM which has a step height pattern with two different widths and various special patterns for checking radial magnification, distortion of optical viewing systems, etc. Especially, it could be useful for multi-probe inspection instruments in the manufacturing lines. The fabrication was done by conventional optical lithography and dry etching process with optimized conditions. To verify the step height values, a white-light scanning interferometer was used with objective lenses having magnification of $10{\times}$ and $100{\times}$. CRMs with nominal step heights of $0.5\;{\mu}m$, $1\;{\mu}m$, $3\;{\mu}m$, $5\;{\mu}m$, $7\;{\mu}m$, and $10\;{\mu}m$ were fabricated and the uniformity of these CRMs was evaluated to be less than 3 nm ($1{\sigma}$).