• Title/Summary/Keyword: reference materials

Search Result 1,945, Processing Time 0.035 seconds

Development of reference materials for mortar: Determination of the components and relation with mixing ratio

  • Lim, Dong Kyu;Choi, Myoung Sung
    • Advances in concrete construction
    • /
    • v.10 no.5
    • /
    • pp.381-391
    • /
    • 2020
  • This study aimed to develop reference materials (RMs) for mortar that can simulate the initial flow characteristics with constant quality over a long period. Through the previous research on the development of RMs for cement paste, the combination of limestone, glycerol, and water was used as the basic matrix for developing RMs for mortar in this study. In addition, glass beads of three particle sizes (0.5, 1.0, and 2.0 mm) and ISO standard sand were selected as tentative candidates to derive fine aggregate substitutes. The mixture of glass beads could simulate the initial flow characteristics of mortar, but under the same mixing ratio, replicates showed an unstable tendency to indicate inconsistent values due to the generation of electrostatic properties between materials and equipment. On the other hand, the mixture using ISO standard Sand not only simulates the constant flow characteristics for a long period of time, but also shows stable results with little error in replicates. Therefore, limestone, glycerol, ISO standard sand, and water were finally determined as components that met the required properties of RMs for mortar. The effect of each component on the flow characteristics of RMs was analyzed. It was found that glycerol increased the cohesion between the particles of standard sand, resulting in a constant increase both in the plastic viscosity and yield stress. Both limestone and standard sand had a dominant effect on the yield stress. The relationships between various mortar mixing ratios and the corresponding mixing ratios of RMs were established. In addition, the results of the verification experiment showed that the rheological properties of the RMs obtained through the relationships correlated with various water/cement ratios and the fine aggregate volume fractions of mortar obtained with same manner. In other words, the RMs for mortar developed in this study can be used as standard samples because they can simulate the initial flow characteristics of mortar of various mixing ratios for a long period without any chemical changes.

Development of reference materials for cement paste

  • Lee, Dong Kyu;Choi, Myoung Sung
    • Advances in concrete construction
    • /
    • v.9 no.6
    • /
    • pp.547-556
    • /
    • 2020
  • This study aimed to develop reference materials (RMs) that are chemically stable and can simulate the flow characteristics of cement paste. To this end, the candidate components of RMs were selected considering the currently required properties of RMs. Limestone, slag, silica, and kaolin were selected as substitutes for cement, while glycerol and corn syrup were selected as matrix fluids. Moreover, distilled water was used for mixing. To select the combinations of materials that meet all the required properties of RMs, flow characteristics were first analyzed. The results revealed that silica and kaolin exhibited bilateral nonlinearity. When an analysis was conducted over time, slag exhibited chemical reactions, including strength development. Moreover, fungi were observed in all mixtures with corn syrup. On the other hand, the combination of limestone, glycerol, and water exhibited a performance that met all the required properties of RMs. Thus, limestone, glycerol, and water were selected as the components of the RMs. When the influence of each component of the RMs on flow characteristics was analyzed, it was found that limestone affects the yield value, while the ratio of water and glycerol affects the plastic viscosity. Based on this, it was possible to select the mixing ratios for the RMs that can simulate the flow characteristics of cement paste under each mixing ratio. This relationship was established as an equation, which was verified under various mixing ratios. Finally, when the flow characteristics were analyzed under various temperature conditions, cement paste and the RMs exhibited similar tendencies in terms of flow characteristics. This indicated that the combinations of the selected materials could be used as RMs that can simulate the flow characteristics of cement paste with constant quality under various mixing ratio conditions and construction environment conditions.

Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations (환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발)

  • Yu, Byung Kyu;Sun, Yle Shik
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.

Measurement of Local Elastic Properties of Flip-chip Bump Materials using Contact Resonance Force Microscopy (접촉 공진 힘 현미경 기술을 이용한 플립 칩 범프 재료의 국부 탄성계수 측정)

  • Kim, Dae-Hyun;Ahn, Hyo-Sok;Hahn, Junhee
    • Tribology and Lubricants
    • /
    • v.28 no.4
    • /
    • pp.173-177
    • /
    • 2012
  • We used contact resonance force microscopy (CRFM) technique to determine the quantitative elastic properties of multiple materials integrated on the sub micrometer scale. The CRFM approach measures the frequencies of an AFM cantilever's first two flexural resonances while in contact with a material. The plain strain modulus of an unknown or test material can be obtained by comparing the resonant spectrum of the test material to that of a reference material. In this study we examined the following bumping materials for flip chip by using copper electrode as a reference material: NiP, Solder (Sn-Au-Cu alloy) and under filled epoxy. Data were analyzed by conventional beam dynamics and contact dynamics. The results showed a good agreement (~15% difference) with corresponding values determined by nanoindentaion. These results provide insight into the use of CRFM methods to attain reliable and accurate measurements of elastic properties of materials on the nanoscale.

Measurement System of the Thermal Diffusivities for Porous Materials under Vacuum Conditions (진공환경에서 다공성 소재의 열확산도 측정 시스템)

  • Kong, Cheol-Won;Nam, Gi-Won;Yi, Yeong-Moo;Ohnishi, Akira
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • A system of measurement for the thermal diffusivity of porous materials was developed. Although there are several measurement systems for thermal diffusivity, it is typically difficult to measure the thermal diffusivity of porous materials. This paper presents a measurement system for thermal diffusivity that utilizes a cyclic heating method along with the verification of the measured device. To verify the cyclic heating method, the available reference data of aceramic specimen was utilized. To apply the system to an actual porous material, polystyrene foam was tested. The thermal diffusivity of the polystyrene foam under vacuum was reduced by 63%. The measured values from both tests were in good agreement with the reference values, as they were within 10% of these values.

Ultrasonic Test Criterion for the Explosively Welded Fe-Naval Brass Bonding Quality (초음파법에 의한 폭발접합 이종금속 접합품질 판정레벨 설정에 관한 연구)

  • 장영권;백영남
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • An ultrasonic test method, as a nondestructive test is applied to ensure the clad interface quality assessment. According to the reference codes and standards, not only korea Industrial Standard(KS) but also American Society for Testing and Materials (ASTM) Standard, ultrasonic examination procedures use the pulse-echo, A-scan, back reflection signal drop method and/or side drilled reference hole used to establish the acceptance criteria of clad material test. But the variety of bonding materials and sizes makes it difficult to produce the reference blocks, or thus the criteria. In order to overcome these practical difficulties, new ultrasonic testing criterion is suggested. In this new method, the theoretical interface reflection signal amplitude level is calculated and suggested as an acceptance criteria with the back reflection signal set to 100% FSH(Full Screen Height) which is based on acoustic impedance mismatch at the clad interface for the explosive clad ultrasonic inspection. Applicability of suggested criterion, for the explosive clad Fe-Naval Brass with different bonding quality is confirmed to the pre-existed KS and ASTM specifications and verified by using SEM (Seanning Electron Microscope) micrograph. The results obtained by the suggested method is more conservative than the results according to the KS B 0234 and ASTM A 578 specifications The suggested method could be applicable to any other combination of explosive clad ultrasonic inspection.

  • PDF

Evaluation of analytical methods for heavy metals and cyanide by certified reference materials (인증표준물질을 이용한 중금속류와 시안화물 전처리방법 비교 연구)

  • Chung, David;Jeon, Tae Wan;Shin, Sun Kyoung
    • Analytical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.163-171
    • /
    • 2006
  • This study was performed to develop an analytical method in specified wastes for preventing the environmental pollution from hazardous wastes. Few analytical methods were developed using the waste standard reference materials of sludge, waste oil, bottom ash, etc. which contain As, CN, Cd, Cr, Cu, Pb, and Hg compounds. The pre-treatment method was considered by whether or not the synchronous analysis is possible. Waste samples obtained from the 34 representative facilities, which are emitting the hazardous substances, were analyzed.

An Analysis of the Instructional State of the Unit 생Small Living Things′ in the Elementary School Science (초등학교 자연과 생작은생물생 단원의 수업 실태 분석)

  • 최도성;최규식;남철우;김정길;김석중;송판섭;한광래;한효의
    • Journal of Korean Elementary Science Education
    • /
    • v.19 no.1
    • /
    • pp.157-170
    • /
    • 2000
  • The purpose of this study is to survey the instructional state of the unit 'Small Living Things' in the Elementary School Science. for this study, 100 teachers were surveyed on teaching-learning practices. More specifically, questions were asked on the degree of accomplishing instruction objectives, frequency of field . study, experimental preparation, alternative instructional methods, amount of preparation, availability of reference books for teachers and availability of information materials on the Kwangju region. Our results show that teachers find the objectives related to the collection of living things for class experiments and the task of growing and observing them the most difficult to accomplish. It was reported that 38% of teachers have actually conducted field trips. The obstacles listed in going out on field study range from lack of knowledge of appropriate places, lack of time, to safety concerns. The most difficult problem in teaching this unit was preparing proper instructional materials, regardless of teacher's gender, career, and interest. Most respondents let children provide the experimental subjects. Teachers with collection experience tend to provide for the experimental materials themselves. Our Analysis also reveals that more than 70% of the respondents do not have adequate knowledge of the species dealt with in the unit. Gender, career, and interest area of the teachers did not make any difference (p< .05). In the case that proper experimental subjects have not been prepared, VTR, textbooks, and charts were reported as the most frequently used alternative instruction aids. The level of content and amount of knowledge contained in this unit were found to be appropriate. Information on instruction materials and experiment-observation were obtained through the teaching manual or periodicals (58%), information materials on the region(20%), and fellow teachers (12%). Reference books for teachers and materials on the region are perceived to be inadequate in order of importance in the areas of preparation method, level-wise learning guide, experimental observation, and information on species covered in text. Overall, it was judged that the highest concern was with obtaining experimental materials, and teacher's reference books and materials on the region need to be reinforced to allow teachers to more fully utilize them. Development and distribution of proper instruction-learning materials to the children's level is also required.

  • PDF

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF