• Title/Summary/Keyword: reference body measurement

Search Result 117, Processing Time 0.029 seconds

A Study on the Suggestion for the Revision of Standard Sizing System for Infant Clothing (유아복의 KS 치수체계 개정을 위한 제안 연구)

  • Jung, Myoung Sook;Suh, Chu Yeon;Lee, Jin Hee
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.118-127
    • /
    • 2014
  • This study proposed a revision of standard sizing system for infant clothing to provide exact information for consumers and manufacturers. The size designation was set up by compensating the defect of existing system. Basic body measurement and reference body measurement were analysed according to size designation. The ages of the infants ranged from 0 to 36 month in accordance with safety standard of KC Self-Regularity Safety Confirmation. The results are as follows: Size designation for infant clothing was based on height that was basic body measurement. Chest girth, waist girth, head girth, arm length, foot length and weight were also analysed according to age of the month. It was proposed that height could be written alone and height with age of month did together for size designation. Size intervals of basic and reference body measurements were fixed as follows: size intervals are 5 cm in height, 2 cm in chest girth, 2 cm in waist girth, 1 cm in head girth, 2 cm in arm length, 0.5 cm in foot length and 2 kg in weight. The distributions of height and chest girth showed normal distributions. As height was taller, chest girth was also bigger. But the distribution of waist girth didn't show remarkable change with age of month. The distributions of arm length and weight showed remarkable difference with growth in 0~9 months, but the amount of growth variation got less in 12~18 months.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

Development of 3-dimensional measuring robot cell (3차원 측정 로보트 셀 개발)

  • Park, Kang;Cho, Koung-Rae;Shin, Hyun-Oh;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1139-1143
    • /
    • 1991
  • Using industrial robots and sensors, we developed an inline car body inspection system which proposes high flexibility and sufficient accuracy. Car Body Inspection(CBI) cell consists of two industrial robots, two corresponding carriages, camera vision system, a process computer with multi-tasking ability and several LDS's. As industrial robots guarantee sufficient repeatabilities, the CBI cell adopts the concept of relative measurement instead of that of absolute measurement. By comparing the actual measured data with reference data, the dimensional errors of the corresponding points can be calculated. The length of the robot arms changes according to ambient temperature and it affects the measuring accuracy. To compensate this error, a robot arm calibration process was realized. By measuring a reference jig, the differential changes of the robot arms due to temperature fluctuation can be calculated and compensated.

  • PDF

Selection and Analysis of the Typical Somatotype for the Development of a Torso Dummy for the Chinese Adult Women

  • Chang, Hee-Kyung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.134-147
    • /
    • 2011
  • This research was motivated to provide the Korean apparel companies doing business in China with some basic data useful to the development of their apparel commodities. As a result of selecting the standard or 'A' somatotype based on the body measurement data of the Chinese women in their early 20's and then, analyzing the correlated distribution and the most frequent intervals, it was found that 'height 160,' 'bust circumference 84' and 'waist circumference 66' were most prevalent. It was found that their average body measurements almost coincided with the standard '160A-84/66.' As discussed above, the researcher selected 13 women corresponding to '160A-84/66' in reference to 2008 body measurement data, and chose 6 women among them secondarily. Then, the researcher comparatively analyzed the direct measurement data and the 3D measurement ones, while analyzing the vertical/horizontal sagittal and Median plane section drawings, it was found that Subject 4 showed the most common somatotype data, while her upper body bent backwards reflected the population most properly.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Liver Size Measurement Method by Ultrasonography and Reference Range based on Normal Adult Physique Index (초음파검사에 의한 간 크기 측정방법 및 정상 성인의 체격지수별 참조범위)

  • Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.13-24
    • /
    • 2018
  • Liver size is an important component in the diagnosis and follow-up of diffuse liver disease when testing for liver disease using ultrasonography. However, difficulties lies in determining the presence of hepatomegaly and liver atrophy because the method used for measuring liver size differs from one examiner to another and there is no relevant standard based on body build. The present study aims to propose a more objective method for liver size measurement and a reference range based on body build. A total of 260 normal adults (130 males, 130 females) participated in the study. Ultrasonography was performed in all participants to measure the size of the right lobe, left lobe, quadrate lobe, and caudate lobe of liver. Based on Physique Index(PI), a value derived from multiplying weight(kg) by height($m^2$), size of physique was divided into three groups including Group I with PI<150, Group II with $150{\leq}PI{\leq}250$, and Group III with PI>250. Thus, mean liver size by PI and a reference range with 95% reliability were suggested. The superoinferior diameter of right lobe was $12.34{\pm}1.18cm$ in males and $11.07{\pm}0.93cm$ in females, and its reference range was 10.64~11.0cm for Group I, 11.78~12.12cm for Group II, and 13.02~13.84cm for Group III. The anteroposterior diameter(T) of left lobe was $5.93{\pm}1.09cm$ in males and $5.18{\pm}0.99cm$ in females, and its reference range was 4.77~5.17cm for Group I, 5.49~5.79cm for Group II, and 6.68~7.44cm for Group III. The transverse diameter was $3.51{\pm}0.60cm$ in male participants and $3.42{\pm}0.49cm$ in female participants and its reference range was 3.29~3.51cm for Group I, 3.36~3.55cm for Group II, and 3.52~4.0cm for Group III. The caudate lobe index was $11.65{\pm}2.88cm^2$ in males and $9.62{\pm}2.18cm^2$ in females and its reference range was $8.83{\sim}9.75cm^2$ for Group I, $10.62{\sim}11.47cm^2$ for Group II, and $11.89{\sim}14.26cm^2$ for Group III. As a basic measurement method of liver size, the present study suggests measuring the superoinferior diameter for right liver lobe, the anteroposterior diameter for left liver lobe, the transverse diameter for quadrate lobe, and the caudate lobe index for caudate lobe. It is expected that this method along with its relevant reference range can be used as useful indicators in determining hepatomegaly and liver atrophy upon the diagnosis and follow-up testing of diffuse liver disease.

A Study on the Development of a Program to Body Circulation Measurement Using the Machine Learning and Depth Camera

  • Choi, Dong-Gyu;Jang, Jong-Wook
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.122-129
    • /
    • 2020
  • The circumference of the body is not only an indicator in order to buy clothes in our life but an important factor which can increase the effectiveness healing properly after figuring out the shape of body in a hospital. There are several measurement tools and methods so as to know this, however, it spends a lot of time because of the method measured by hand for accurate identification, compared to the modern advanced societies. Also, the current equipments for automatic body scanning are not easy to use due to their big volume or high price generally. In this papers, OpenPose model which is a deep learning-based Skeleton Tracking is used in order to solve the problems previous methods have and for ease of application. It was researched to find joints and an approximation by applying the data of the deep camera via reference data of the measurement parts provided by the hospitals and to develop a program which is able to measure the circumference of the body lighter and easier by utilizing the elliptical circumference formula.

Anthropometric measurement and Comparative Study about Fat estimation methods for the Elderly (노인들의 신체계측지와 체지방 추정 방법들간의 비교연구 -피하지방두께, 임피던스, 근적외선법-)

  • 한경희
    • Korean Journal of Community Nutrition
    • /
    • v.1 no.3
    • /
    • pp.405-422
    • /
    • 1996
  • The purpose of this study is provide reference data for anthropometry and body composition and also to compare body fat estimation among skinfold thickness, BIA and NIR methods. Anthropometric measurements of height, weight, eight sites of skinfolds and six sites of circumferences were taken from 76 elderly male and 153 elderly female. Skinfold thicknesses, body composition and circumferences except waist were lowered with advancing age in elderly females and males. The degree of change with age vaired among parameters but was consistently and significantly(p<0.05) greater in elderly females than I males. Although sum of skinfold thicknesses and the amount of central and peripheral fat were significantly higher in females than that of males, the ratio of central fat to peripheral fat was significantly greater in males than in females. WHR is also significantly higher in males than that of females. This indicates that fat distribution of males tend to be centralized toward the trunk of the body than females. Estimation of body fat from skinfold thickness(male : 18.5$\pm$4.1$\%$, female : 29.7$\pm$4.0$\%$) and BIA(male : 19.5$\pm$7.3$\%$, female : 29.6$\pm$6.7$\%$) were similar but were significantly different from NIR method(male : 24.7$\pm$5.6$\%$, 34.8$\pm$4.9$\%$). Estimation of body fat by NIR measurement seemed to be more overestimated. Understanding the normal changes in body composition with increasing old age, and the ability to measure these changes and compare them with appropriate reference data are important for the health of the elderly.

  • PDF

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor (마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구)

  • Lee, Kang-Hwi;Lee, Sung-Su;Lee, Jeong-Whan;Song, Ha-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.